Load flow and short-circuit study, Neo 5 seriesSample

by Vidyutline Technical Services (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Vidyutline Technical Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Vidyutline Neo 5 load flow and short-circuit study, offered in 5 network scale options from 11 kV plant to 220 kV system. Design: fault level verification of switchgear, models acceptable to STU and CTUIL and relay setting files ready to load. Suited to BESS integrators, renewable developers seeking connectivity and industrial plants adding generation. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation Kick-off in 1 week; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Vidyutline
Model
VID-468 series
Listing type
Service
Unit
report
Minimum order
1 report
Lead time
Kick-off in 1 week
Warranty
Revision for utility comments
Standards
CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
Delivers to
All India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Network scale11 kV plantVID-468-01Network scale: 11 kV plant1 report · Kick-off in 1 weekon quote
Network scale33 kV plantVID-468-02Network scale: 33 kV plant1 report · Kick-off in 1 weekon quote
Network scale66 kV systemVID-468-03Network scale: 66 kV system1 report · Kick-off in 1 weekon quote
Network scale132 kV systemVID-468-04Network scale: 132 kV system1 report · 2-6 weekson quote
Network scale220 kV systemVID-468-05Network scale: 220 kV system1 report · 2-6 weekson quote

Specifications

Network scale11 kV plant to 220 kV system (see variants)
Study typeHarmonics
SoftwareDIgSILENT PowerFactory
Model dataClient single line diagram and datamade to order: Utility network model
DeliverablesModel files and relay settings
Grid code checksVoltage and reactive power capabilitymade to order: LVRT/HVRT and ramp rate
ReviewLender review
ScenariosMultiple dispatch casesmade to order: Normal and N-1
TeamLead plus modelling specialist
Turnaround4-6 weeks
ValidationCompared with measured data