Merchants / VINDHYASWITCHBOARD

Vindhya Switchboards (Sample)

Vindhya Switchboards Pvt Ltd (Sample)

Verified by BARREL — PAN, GSTIN and company records checked; NDA and non-circumvention signed

Catalogue · 15 listings

Send an RFQ

Prices are shown to verified buyers. Register your company to see them and request quotes. Questions, quotes, orders and invoices all go through BARREL Shop.

MV metal-clad switchboards (11–33 kV)

Indoor MV switchgear panel with VCB, Ultra 3 series

SampleMV metal-clad switchboards (11–33 kV)

Vindhya · VIN-B86 series

Rating
11 kV 1250 A to 33 kV 2500 A (see variants)
Insulation
Solid insulated
Short-circuit rating
25 kA/3 s
Panel function
Bus coupler
Busbar
Single busbar

Lead time 8-10 weeks · Warranty 24 months from supply · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Withdrawable vacuum switchgear board, Smart 5 series

SampleMV metal-clad switchboards (11–33 kV)

Vindhya · VIN-935 series

Rating
11 kV 2500 A to 33 kV 2500 A (see variants)
Insulation
Solid insulated
Short-circuit rating
40 kA/3 s
Panel function
Metering PT
Busbar
Single busbar

Lead time 8-10 weeks · Warranty 24 months from supply · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Changeover switches & ATS panels

On-load changeover switch, Smart series

SampleChangeover switches & ATS panels

Vindhya · VIN-B42 series

Rating
250 A to 2500 A (see variants)
Type
ATS panel
Poles
3P
Rated voltage
415 V AC
Transfer device
Switch-disconnector

Lead time 4-6 weeks · Warranty 18 months from supply · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Genset to mains ATS panel with controller, Titan 8 series

SampleChangeover switches & ATS panels

Vindhya · VIN-259 series

Rating
1000 A to 2500 A (see variants)
Type
Motorised changeover
Poles
3P
Rated voltage
415 V AC
Transfer device
Switch-disconnector

Lead time 1-2 weeks · Warranty 12 months from commissioning · MOQ 10 nos

Price on quote

invoiced by BARREL

Request quote

Ring main units (RMU)

11 kV ring main unit, Titan series

SampleRing main units (RMU)

Vindhya · VIN-EC1 series

Configuration
2-way (LBS+LBS) to 3-way (LBS+LBS+VCB) (see variants)
Rated voltage
12 kV
Rated current - ring
630 A
Transformer feeder
630 A VCB
Short-circuit rating
25 kA/3 s

Lead time 4-6 weeks · Warranty 24 months from supply · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

VCB panels

Vindhya · VIN-572 series

Rating
11 kV 2000 A to 33 kV 1250 A (see variants)
Short-circuit rating
40 kA/3 s
Construction
Metal-enclosed fixed
Breaker operating duty
O-0.3 s-CO-3 min-CO
Control voltage
30 V DC

Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Vindhya · VIN-383 series

Rating
11 kV 1250 A to 33 kV 630 A (see variants)
Short-circuit rating
31.5 kA/3 s
Construction
Metal-enclosed fixed
Breaker operating duty
O-0.3 s-CO-3 min-CO
Control voltage
30 V DC

Lead time 8-10 weeks · Warranty 18 months from supply · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

ACB, MCCB & MCB

Vindhya · VIN-2A4 series

Rating
63 A to 250 A (see variants)
Breaker type
ACB
Poles
2P
Rated voltage
240 V AC
Breaking capacity (Icu)
50 kA

Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Vindhya · VIN-275 series

Rating
1250 A to 4000 A (see variants)
Breaker type
MCCB
Poles
4P
Rated voltage
415 V AC
Breaking capacity (Icu)
85 kA

Lead time 3-5 weeks · Warranty 24 months from supply · MOQ 10 nos

Price for verified buyers

invoiced by BARREL

Request quote

PCC, MCC, ACDB, DCDB

Vindhya · VIN-6C7 series

Rating
630 A to 1600 A (see variants)
Panel type
DCDB
System voltage
220 V DC
Short-circuit rating
65 kA/1 s
Form of separation
Form 3b

Lead time 3-4 weeks · Warranty 12 months from commissioning · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Vindhya · VIN-A43 series

Rating
400 A to 1600 A (see variants)
Panel type
ACDB
System voltage
220 V DC
Short-circuit rating
50 kA/1 s
Form of separation
Form 4b

Lead time 6-8 weeks · Warranty 12 months from commissioning · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Bus ducts

Vindhya · VIN-457 series

Rating
400 A to 1000 A (see variants)
Conductor
Aluminium
Rated voltage
415 V
Construction
Air-insulated
Short-circuit withstand
100 kA/1 s

Lead time 8-10 weeks · Warranty 24 months from supply · MOQ 10 m

Price for verified buyers

invoiced by BARREL

Request quote

Vindhya · VIN-339 series

Rating
630 A to 4000 A (see variants)
Conductor
Copper
Rated voltage
1000 V
Construction
Air-insulated
Short-circuit withstand
50 kA/1 s

Lead time 8-10 weeks · Warranty 12 months from commissioning · MOQ 1 m

Price for verified buyers

invoiced by BARREL

Request quote

Contactors, overload relays & motor starters

AC power contactor, Eco 2 series

SampleContactors, overload relays & motor starters

Vindhya · VIN-5B5 series

Rating
9 A to 65 A (see variants)
Device type
Overload relay
Coil voltage
110 V AC
Utilisation category
AC-4
Motor rating at 415 V
15 kW

Lead time 3-4 weeks · Warranty 18 months from supply · MOQ 10 nos

Price for verified buyers

invoiced by BARREL

Request quote

AC power contactor, Prime series

SampleContactors, overload relays & motor starters

Vindhya · VIN-5B6 series

Rating
65 A to 185 A (see variants)
Device type
Contactor
Coil voltage
110 V AC
Utilisation category
AC-4
Motor rating at 415 V
200 kW

Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

BARREL: Bharat Atom Renewable Resources Energy Limited