SFRA, winding resistance & turns-ratio testersMalwa5 variants
SampleSFRA, winding resistance & turns-ratio testers Malwa · MAL-E21 series
- Test current / range
- 1 A winding resistance to TTR 0.8-10000 (see variants)
- Instrument
- SFRA
- Accuracy
- 0.5%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 24 months with calibration · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersPushpakline4 variants
SampleSFRA, winding resistance & turns-ratio testers Pushpakline · PUS-9D8 series
- Test current / range
- 1 A winding resistance to 40 A winding resistance (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 24 months with calibration · MOQ 10 nos
SFRA, winding resistance & turns-ratio testersKonarkakshay4 variants
SampleSFRA, winding resistance & turns-ratio testers Konarkakshay · KON-4F3 series
- Test current / range
- 10 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- SFRA
- Accuracy
- 0.5%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 24 months with calibration · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersMadurai6 variants
SampleSFRA, winding resistance & turns-ratio testers Madurai · MAD-9D5 series
- Test current / range
- 1 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- Turns ratio
- Accuracy
- 0.5%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersPallavasamarth6 variants
SampleSFRA, winding resistance & turns-ratio testers Pallavasamarth · PAL-4F4 series
- Test current / range
- 1 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- SFRA
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersMagadhlumen6 variants
SampleSFRA, winding resistance & turns-ratio testers Magadhlumen · MAG-365 series
- Test current / range
- 1 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersBrahmaputra3 variants
SampleSFRA, winding resistance & turns-ratio testers Brahmaputra · BRA-4F5 series
- Test current / range
- 5 A winding resistance to 40 A winding resistance (see variants)
- Instrument
- SFRA
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersEllora3 variants
SampleSFRA, winding resistance & turns-ratio testers Ellora · ELL-E21 series
- Test current / range
- 10 A winding resistance to TTR 0.8-10000 (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersShivalik5 variants
SampleSFRA, winding resistance & turns-ratio testers Shivalik · SHI-366 series
- Test current / range
- 5 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersNarmadaphase6 variants
SampleSFRA, winding resistance & turns-ratio testers Narmadaphase · NAR-369 series
- Test current / range
- 1 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- Turns ratio
- Accuracy
- 0.5%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 24 months with calibration · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersPushpakline3 variants
SampleSFRA, winding resistance & turns-ratio testers Pushpakline · PUS-367 series
- Test current / range
- 10 A winding resistance to TTR 0.8-10000 (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersMalwa5 variants
SampleSFRA, winding resistance & turns-ratio testers Malwa · MAL-4F6 series
- Test current / range
- 5 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- Turns ratio
- Accuracy
- 0.5%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersKamrupphase4 variants
SampleSFRA, winding resistance & turns-ratio testers Kamrupphase · KAM-9D4 series
- Test current / range
- 1 A winding resistance to 40 A winding resistance (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 24 months with calibration · MOQ 10 nos
SFRA, winding resistance & turns-ratio testersHoysala3 variants
SampleSFRA, winding resistance & turns-ratio testers Hoysala · HOY-E22 series
- Test current / range
- 10 A winding resistance to TTR 0.8-10000 (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 24 months with calibration · MOQ 2 nos
SFRA, winding resistance & turns-ratio testersKamrupsamarth5 variants
SampleSFRA, winding resistance & turns-ratio testers Kamrupsamarth · KAM-9D3 series
- Test current / range
- 1 A winding resistance to TTR 0.8-10000 (see variants)
- Instrument
- Turns ratio
- Accuracy
- 0.5%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 2 nos
SFRA, winding resistance & turns-ratio testersSetucore3 variants
SampleSFRA, winding resistance & turns-ratio testers Setucore · SET-4F4 series
- Test current / range
- 5 A winding resistance to 40 A winding resistance (see variants)
- Instrument
- Turns ratio
- Accuracy
- 0.5%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 nos