Test & measurement

Diagnostic and commissioning test equipment.

Companies offering this · 26

Listings (406)

Prices are shown to verified buyers. Register your company to see them and request quotes.

Primary injection test set, Prime 6 series

SamplePrimary & secondary injection kits

Akshaymark · AKS-F45 series

Output current
500 A to 2000 A (see variants)
Output voltage
24 V
Duty cycle
Continuous 100 A
Supply
230 V AC
Meters
Built-in timer

Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 2 set

Price for verified buyers

by Akshaymark Test Equipment (Sample) · invoiced by BARREL

Request quote

Setucore · SET-7C3 series

Output channels
3 voltage + 3 current to 6V + 12I (see variants)
Current output
128 A combined
Voltage output
0-150 V
Frequency range
10-1000 Hz
Accuracy
0.05%

Lead time 2-4 weeks · Warranty 24 months extended option · MOQ 2 set

Price for verified buyers

by Setucore Test Equipment (Sample) · invoiced by BARREL

Request quote

Motorised megger, Ultra series

SampleInsulation & tan delta testers

Madurai · MAD-CD5 series

Maximum test voltage
5 kV to 12 kV (see variants)
Resistance range
Up to 10 Tohm
Tests
IR, PI, DAR, DD
Display
Colour TFT
Power supply
230 V AC and battery

Lead time 1-2 weeks · Warranty 24 months with calibration · MOQ 1 nos

Price for verified buyers

by Madurai Test Equipment (Sample) · invoiced by BARREL

Request quote

True RMS digital multimeter, Max series

SampleMultimeters, clamp meters & insulation testers

Setucore · SET-D03 series

Maximum current / voltage range
600 A to 3000 A (flexible) (see variants)
Measurement
Capacitance
Display count
10000
Accuracy
1%
Safety rating
CAT III 600 V

Lead time 3-7 days · Warranty 3 years limited · MOQ 2 nos

Price for verified buyers

by Setucore Test Equipment (Sample) · invoiced by BARREL

Request quote

Voltage transformer test set, Plus 2 series

SampleCT/PT & transformer analysers

Kamrupsamarth · KAM-075 series

Test channels / output
3-phase 5 kV to Multi-function 60 A (see variants)
Tests
Winding resistance
Class tested
Class 0.2 to 5P
Output current
0-30 A
Output voltage
0-2000 V

Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 1 nos

Price on quote

by Kamrupsamarth Testing Solutions (Sample) · invoiced by BARREL

Request quote

Motorised megger, Edge series

SampleInsulation & tan delta testers

Shivalik · SHI-CD3 series

Maximum test voltage
2.5 kV to 10 kV (see variants)
Resistance range
Up to 15 Tohm
Tests
Tan delta, capacitance
Display
LCD
Power supply
230 V AC and battery

Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 1 nos

Price on quote

by Shivalik Testing Solutions (Sample) · invoiced by BARREL

Request quote

Partial discharge detector, Prime series

SamplePartial discharge & VLF testers

Dwarakasamarth · DWA-D49 series

Test voltage (VLF peak)
34 kV to 60 kV (see variants)
Test frequency
0.1 Hz
Waveform
Cosine rectangular
Max load capacitance
0.5 microF
PD sensitivity
Below 5 pC

Lead time 8-14 weeks · Warranty 24 months with calibration · MOQ 2 set

Price for verified buyers

by Dwarakasamarth Test Equipment (Sample) · invoiced by BARREL

Request quote

VLF very low frequency test set, Neo 2 series

SamplePartial discharge & VLF testers

Madurai · MAD-333 series

Test voltage (VLF peak)
50 kV to 90 kV (see variants)
Test frequency
0.05 Hz to 0.1 Hz
Waveform
Cosine rectangular
Max load capacitance
1.1 microF
PD sensitivity
Below 1 pC

Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 5 set

Price for verified buyers

by Madurai Test Equipment (Sample) · invoiced by BARREL

Request quote

PV I-V curve tracer, Elite 6 series

SampleI-V curve tracers & EL testers (solar)

Dwarakasamarth · DWA-2B9 series

Max DC voltage / current
1000 V 10 A to EL camera 20 MP (see variants)
Measurement
EL imaging
Irradiance sensor
Pyranometer
Temperature sensor
IR thermometer
Accuracy
+/-0.5%

Lead time 3-4 weeks · Warranty 24 months with calibration · MOQ 2 nos

Price for verified buyers

by Dwarakasamarth Test Equipment (Sample) · invoiced by BARREL

Request quote

Cable route tracer, Pro series

SampleCable fault locators

Deccanarc · DEC-891 series

Surge voltage
8 kV to 20 kV (see variants)
Surge energy
2000 J
Methods
TDR, ARM, Decay
Cable length range
Up to 20 km
Display
Monochrome

Lead time 8-12 weeks · Warranty 24 months on request · MOQ 5 set

Price for verified buyers

by Deccanarc Test Equipment (Sample) · invoiced by BARREL

Request quote

CT/PT analyser, Prime series

SampleCT/PT & transformer analysers

Maurya · MAU-511 series

Test channels / output
3-phase 5 kV to Multi-function 60 A (see variants)
Tests
Knee point, excitation
Class tested
Class 0.2 to 5P
Output current
0-100 A
Output voltage
0-250 V

Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 10 nos

Price on quote

by Maurya Test Instruments (Sample) · invoiced by BARREL

Request quote

Transformer test system, Core 3 series

SampleCT/PT & transformer analysers

Setucore · SET-097 series

Test channels / output
Single channel 5 kV to 3-phase 10 kV (see variants)
Tests
Ratio, polarity, burden
Class tested
PS class
Output current
0-100 A
Output voltage
0-2000 V

Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 1 nos

Price for verified buyers

by Setucore Test Equipment (Sample) · invoiced by BARREL

Request quote

Cable test set 0.1 Hz, Pro series

SamplePartial discharge & VLF testers

Brahmaputra · BRA-912 series

Test voltage (VLF peak)
50 kV to 90 kV (see variants)
Test frequency
0.1 Hz
Waveform
Cosine rectangular
Max load capacitance
1.1 microF
PD sensitivity
Below 5 pC

Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 1 set

Price for verified buyers

by Brahmaputra Test Instruments (Sample) · invoiced by BARREL

Request quote

PV I-V curve tracer, Edge series

SampleI-V curve tracers & EL testers (solar)

Ellora · ELL-2B7 series

Max DC voltage / current
1500 V 15 A to 1500 V 30 A (see variants)
Measurement
EL imaging
Irradiance sensor
Reference cell
Temperature sensor
PT1000 cell
Accuracy
+/-0.5%

Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 nos

Price for verified buyers

by Ellora Test Equipment (Sample) · invoiced by BARREL

Request quote

AC/DC clamp meter, Xtra series

SampleMultimeters, clamp meters & insulation testers

Konarkakshay · KON-954 series

Maximum current / voltage range
600 A to 1000 V DC (see variants)
Measurement
Capacitance
Display count
6000
Accuracy
1%
Safety rating
CAT III 600 V

Lead time 3-7 days · Warranty 3 years limited · MOQ 10 nos

Price on quote

by Konarkakshay Test Instruments (Sample) · invoiced by BARREL

Request quote

Narmadaphase · NAR-B57 series

Output channels
3 voltage + 3 current to 3V + 6I with GOOSE (see variants)
Current output
32 A per channel
Voltage output
0-300 V
Frequency range
DC to 1 kHz
Accuracy
0.1%

Lead time 2-4 weeks · Warranty 24 months extended option · MOQ 10 set

Price for verified buyers

by Narmadaphase Test Instruments (Sample) · invoiced by BARREL

Request quote

BARREL: Bharat Atom Renewable Resources Energy Limited