Insulation & tan delta testersMalwa5 variants
SampleInsulation & tan delta testers Malwa · MAL-DA1 series
- Maximum test voltage
- 2.5 kV to 15 kV (see variants)
- Resistance range
- Up to 15 Tohm
- Tests
- IR, PI, DAR, DD
- Display
- Colour TFT
- Power supply
- 230 V AC and battery
Lead time 1-2 weeks · Warranty 24 months with calibration · MOQ 1 nos
Primary & secondary injection kitsCoromandel6 variants
SamplePrimary & secondary injection kits Coromandel · COR-BB4 series
- Output current
- 100 A to 6000 A (see variants)
- Output voltage
- 24 V
- Duty cycle
- Short time 5 min
- Supply
- 415 V AC
- Meters
- Digital ammeter 0.5%
Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 10 set
I-V curve tracers & EL testers (solar)Brahmaputra3 variants
SampleI-V curve tracers & EL testers (solar) Brahmaputra · BRA-077 series
- Max DC voltage / current
- 1500 V 15 A to 1500 V 30 A (see variants)
- Measurement
- EL imaging
- Irradiance sensor
- Reference cell
- Temperature sensor
- IR thermometer
- Accuracy
- +/-1%
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 5 nos
SFRA, winding resistance & turns-ratio testersKamrupphase4 variants
SampleSFRA, winding resistance & turns-ratio testers Kamrupphase · KAM-9D4 series
- Test current / range
- 1 A winding resistance to 40 A winding resistance (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 24 months with calibration · MOQ 10 nos
Earth & soil resistivity testersDeccanarc5 variants
SampleEarth & soil resistivity testers Deccanarc · DEC-413 series
- Measuring range
- 0-20 ohm to 0-30 kohm (see variants)
- Method
- 4-pole Wenner
- Test frequency
- 128 Hz
- Test current
- Up to 50 mA
- Accuracy
- +/-2%
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 10 nos
SFRA, winding resistance & turns-ratio testersHoysala3 variants
SampleSFRA, winding resistance & turns-ratio testers Hoysala · HOY-E22 series
- Test current / range
- 10 A winding resistance to TTR 0.8-10000 (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 24 months with calibration · MOQ 2 nos
I-V curve tracers & EL testers (solar)Shaktimark4 variants
SampleI-V curve tracers & EL testers (solar) Shaktimark · SHA-6D4 series
- Max DC voltage / current
- 1500 V 15 A to EL camera 10 MP (see variants)
- Measurement
- I-V curve
- Irradiance sensor
- Reference cell
- Temperature sensor
- PT1000 cell
- Accuracy
- +/-0.5%
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 2 nos
Partial discharge & VLF testersMagadhlumen4 variants
SamplePartial discharge & VLF testers Magadhlumen · MAG-598 series
- Test voltage (VLF peak)
- 50 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 1.1 microF
- PD sensitivity
- Below 1 pC
Lead time 8-14 weeks · Warranty 12 months from supply · MOQ 2 set
I-V curve tracers & EL testers (solar)Pallavasamarth5 variants
SampleI-V curve tracers & EL testers (solar) Pallavasamarth · PAL-071 series
- Max DC voltage / current
- 1500 V 15 A to EL camera 20 MP (see variants)
- Measurement
- EL imaging
- Irradiance sensor
- Reference cell
- Temperature sensor
- IR thermometer
- Accuracy
- +/-1%
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 10 nos
SFRA, winding resistance & turns-ratio testersKamrupsamarth5 variants
SampleSFRA, winding resistance & turns-ratio testers Kamrupsamarth · KAM-9D3 series
- Test current / range
- 1 A winding resistance to TTR 0.8-10000 (see variants)
- Instrument
- Turns ratio
- Accuracy
- 0.5%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 2 nos
CT/PT & transformer analysersDeccanarc3 variants
SampleCT/PT & transformer analysers Deccanarc · DEC-077 series
- Test channels / output
- 3-phase 10 kV to Multi-function 60 A (see variants)
- Tests
- Winding resistance
- Class tested
- PS class
- Output current
- 0-100 A
- Output voltage
- 0-2000 V
Lead time 2-3 weeks · Warranty 24 months with calibration · MOQ 5 nos
Relay test kitsHoysala4 variants
Hoysala · HOY-184 series
- Output channels
- 3 voltage + 3 current to 3V + 6I with GOOSE (see variants)
- Current output
- 32 A per channel
- Voltage output
- 0-150 V
- Frequency range
- 10-1000 Hz
- Accuracy
- 0.1%
Lead time 2-4 weeks · Warranty 24 months extended option · MOQ 1 set
CT/PT & transformer analysersKamrupphase4 variants
SampleCT/PT & transformer analysers Kamrupphase · KAM-518 series
- Test channels / output
- Single channel 5 kV to Multi-function 30 A (see variants)
- Tests
- Knee point, excitation
- Class tested
- PS class
- Output current
- 0-100 A
- Output voltage
- 0-2000 V
Lead time 2-3 weeks · Warranty 24 months with calibration · MOQ 10 nos
Primary & secondary injection kitsDeccanarc3 variants
SamplePrimary & secondary injection kits Deccanarc · DEC-F47 series
- Output current
- 500 A to 2000 A (see variants)
- Output voltage
- 6 V
- Duty cycle
- Continuous 100 A
- Supply
- 415 V AC
- Meters
- Built-in timer
Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 10 set
CT/PT & transformer analysersMagadhlumen3 variants
SampleCT/PT & transformer analysers Magadhlumen · MAG-DA3 series
- Test channels / output
- 3-phase 5 kV to Multi-function 30 A (see variants)
- Tests
- Ratio, polarity, burden
- Class tested
- PS class
- Output current
- 0-100 A
- Output voltage
- 0-250 V
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 2 nos
Thermal camerasHoysala3 variants
Hoysala · HOY-D95 series
- Detector resolution
- 80 x 60 to 240 x 180 (see variants)
- Temperature range
- -20 to 1200 deg C
- Thermal sensitivity
- Below 0.1 deg C
- Accuracy
- +/-2 deg C
- Focus
- Autofocus
Lead time 1-2 weeks · Warranty 10 years detector warranty (limited) · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersSetucore3 variants
SampleSFRA, winding resistance & turns-ratio testers Setucore · SET-4F4 series
- Test current / range
- 5 A winding resistance to 40 A winding resistance (see variants)
- Instrument
- Turns ratio
- Accuracy
- 0.5%
- Frequency range
- 10 Hz to 25 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 nos
Thermal camerasMalwa6 variants
Malwa · MAL-FA7 series
- Detector resolution
- 80 x 60 to 640 x 480 (see variants)
- Temperature range
- -20 to 650 deg C
- Thermal sensitivity
- Below 0.05 deg C
- Accuracy
- +/-2 deg C
- Focus
- Manual
Lead time 3-5 weeks · Warranty 10 years detector warranty (limited) · MOQ 1 nos
CT/PT & transformer analysersMahanadi5 variants
SampleCT/PT & transformer analysers Mahanadi · MAH-079 series
- Test channels / output
- Single channel 2 kV to Multi-function 30 A (see variants)
- Tests
- Winding resistance
- Class tested
- Class 0.2 to 5P
- Output current
- 0-100 A
- Output voltage
- 0-250 V
Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 5 nos
CT/PT & transformer analysersNarmadaphase4 variants
SampleCT/PT & transformer analysers Narmadaphase · NAR-DA5 series
- Test channels / output
- Single channel 5 kV to Multi-function 30 A (see variants)
- Tests
- Knee point, excitation
- Class tested
- PS class
- Output current
- 0-30 A
- Output voltage
- 0-2000 V
Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 1 nos
Relay test kitsMagadhlumen4 variants
Magadhlumen · MAG-183 series
- Output channels
- 3 voltage + 3 current to 3V + 6I with GOOSE (see variants)
- Current output
- 32 A per channel
- Voltage output
- 0-150 V
- Frequency range
- 10-1000 Hz
- Accuracy
- 0.1%
Lead time 6-10 weeks · Warranty 24 months extended option · MOQ 1 set
Primary & secondary injection kitsPallavasamarth4 variants
SamplePrimary & secondary injection kits Pallavasamarth · PAL-3D4 series
- Output current
- 100 A to 2000 A (see variants)
- Output voltage
- 12 V
- Duty cycle
- Continuous 100 A
- Supply
- 415 V AC
- Meters
- Built-in timer
Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 1 set