CT/PT & transformer analysersHoysala5 variants
SampleCT/PT & transformer analysers Hoysala · HOY-DA1 series
- Test channels / output
- Single channel 2 kV to Multi-function 30 A (see variants)
- Tests
- Ratio, polarity, burden
- Class tested
- Class 0.2 to 5P
- Output current
- 0-100 A
- Output voltage
- 0-2000 V
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 1 nos
Circuit-breaker analysersMadurai5 variants
SampleCircuit-breaker analysers Madurai · MAD-FB4 series
- Timing channels
- 3 channels to 18 channels (see variants)
- Time resolution
- 0.05 ms
- Travel transducer
- Rotary
- DC contact resistance
- 200 A
- Coil current
- Measured
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 10 nos
Primary & secondary injection kitsHoysala3 variants
SamplePrimary & secondary injection kits Hoysala · HOY-F41 series
- Output current
- 500 A to 2000 A (see variants)
- Output voltage
- 24 V
- Duty cycle
- Continuous 100 A
- Supply
- 415 V AC
- Meters
- Digital ammeter 0.5%
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 2 set
I-V curve tracers & EL testers (solar)Mahanadi5 variants
SampleI-V curve tracers & EL testers (solar) Mahanadi · MAH-FD2 series
- Max DC voltage / current
- 1500 V 15 A to EL camera 20 MP (see variants)
- Measurement
- I-V curve
- Irradiance sensor
- Pyranometer
- Temperature sensor
- IR thermometer
- Accuracy
- +/-0.5%
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 2 nos
Insulation & tan delta testersNarmadaphase4 variants
SampleInsulation & tan delta testers Narmadaphase · NAR-DA4 series
- Maximum test voltage
- 2.5 kV to 12 kV (see variants)
- Resistance range
- Up to 15 Tohm
- Tests
- Tan delta, capacitance
- Display
- Colour TFT
- Power supply
- Rechargeable battery
Lead time 4-6 weeks · Warranty 12 months from supply · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersPallavasamarth4 variants
SampleSFRA, winding resistance & turns-ratio testers Pallavasamarth · PAL-E25 series
- Test current / range
- 10 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- SFRA
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
Circuit-breaker analysersMalwa3 variants
SampleCircuit-breaker analysers Malwa · MAL-FB7 series
- Timing channels
- 9 channels to 18 channels (see variants)
- Time resolution
- 0.05 ms
- Travel transducer
- Rotary
- DC contact resistance
- 200 A
- Coil current
- Measured
Lead time 6-8 weeks · Warranty 24 months with calibration · MOQ 1 nos
Relay test kitsKamrupsamarth4 variants
Kamrupsamarth · KAM-7C7 series
- Output channels
- 4 voltage + 6 current to 6V + 12I (see variants)
- Current output
- 32 A per channel
- Voltage output
- 0-300 V
- Frequency range
- 10-1000 Hz
- Accuracy
- 0.05%
Lead time 2-4 weeks · Warranty 24 months extended option · MOQ 10 set
Cable fault locatorsKalingavajra4 variants
SampleCable fault locators Kalingavajra · KAL-8C6 series
- Surge voltage
- 8 kV to 20 kV (see variants)
- Surge energy
- 2000 J
- Methods
- Pulse echo, ARM, SIM
- Cable length range
- Up to 20 km
- Display
- Colour touch
Lead time 3-4 weeks · Warranty 24 months on request · MOQ 1 set
SFRA, winding resistance & turns-ratio testersVijaya4 variants
SampleSFRA, winding resistance & turns-ratio testers Vijaya · VIJ-367 series
- Test current / range
- 5 A winding resistance to TTR 0.8-10000 (see variants)
- Instrument
- SFRA
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 1 nos
Cable fault locatorsHoysala6 variants
SampleCable fault locators Hoysala · HOY-689 series
- Surge voltage
- 8 kV to 40 kV (see variants)
- Surge energy
- 2000 J
- Methods
- Pulse echo, ARM, SIM
- Cable length range
- Up to 20 km
- Display
- Monochrome
Lead time 8-12 weeks · Warranty 12 months from supply · MOQ 1 set
Earth & soil resistivity testersMadurai3 variants
SampleEarth & soil resistivity testers Madurai · MAD-417 series
- Measuring range
- 0-200 ohm to 0-20 kohm (see variants)
- Method
- Clamp-on
- Test frequency
- Auto-select 94-128 Hz
- Test current
- Up to 50 mA
- Accuracy
- +/-2%
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 1 nos
I-V curve tracers & EL testers (solar)Awadh6 variants
SampleI-V curve tracers & EL testers (solar) Awadh · AWA-6D7 series
- Max DC voltage / current
- 1000 V 10 A to EL camera 20 MP (see variants)
- Measurement
- EL imaging
- Irradiance sensor
- Reference cell
- Temperature sensor
- PT1000 cell
- Accuracy
- +/-1%
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersAkshaymark3 variants
SampleSFRA, winding resistance & turns-ratio testers Akshaymark · AKS-E25 series
- Test current / range
- 5 A winding resistance to 40 A winding resistance (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 1 nos
CT/PT & transformer analysersPushpakline5 variants
SampleCT/PT & transformer analysers Pushpakline · PUS-DA6 series
- Test channels / output
- Single channel 5 kV to Multi-function 60 A (see variants)
- Tests
- Winding resistance
- Class tested
- PS class
- Output current
- 0-30 A
- Output voltage
- 0-250 V
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 5 nos
I-V curve tracers & EL testers (solar)Vijaya5 variants
SampleI-V curve tracers & EL testers (solar) Vijaya · VIJ-2B9 series
- Max DC voltage / current
- 1500 V 15 A to EL camera 20 MP (see variants)
- Measurement
- EL imaging
- Irradiance sensor
- Pyranometer
- Temperature sensor
- PT1000 cell
- Accuracy
- +/-1%
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 nos
Primary & secondary injection kitsSudarshanmark5 variants
SamplePrimary & secondary injection kits Sudarshanmark · SUD-3D5 series
- Output current
- 500 A to 6000 A (see variants)
- Output voltage
- 24 V
- Duty cycle
- Continuous 100 A
- Supply
- 415 V AC
- Meters
- Built-in timer
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 10 set
Thermal camerasSudarshanmark5 variants
Sudarshanmark · SUD-D97 series
- Detector resolution
- 80 x 60 to 384 x 288 (see variants)
- Temperature range
- -20 to 350 deg C
- Thermal sensitivity
- Below 0.1 deg C
- Accuracy
- +/-2%
- Focus
- Manual
Lead time 3-5 weeks · Warranty 24 months from supply · MOQ 5 nos
Multimeters, clamp meters & insulation testersMagadhlumen5 variants
SampleMultimeters, clamp meters & insulation testers Magadhlumen · MAG-D06 series
- Maximum current / voltage range
- 600 A to 3000 A (flexible) (see variants)
- Measurement
- AC/DC current
- Display count
- 10000
- Accuracy
- 0.5%
- Safety rating
- CAT IV 600 V
Lead time 1-2 weeks · Warranty 3 years limited · MOQ 2 nos
SFRA, winding resistance & turns-ratio testersKalingavajra6 variants
SampleSFRA, winding resistance & turns-ratio testers Kalingavajra · KAL-9D1 series
- Test current / range
- 1 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- Turns ratio
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 2 nos
Relay test kitsDeccan5 variants
Deccan · DEC-184 series
- Output channels
- 3 voltage + 3 current to 6V + 12I (see variants)
- Current output
- 128 A combined
- Voltage output
- 0-150 V
- Frequency range
- DC to 1 kHz
- Accuracy
- 0.05%
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 set
Multimeters, clamp meters & insulation testersKalingavajra5 variants
SampleMultimeters, clamp meters & insulation testers Kalingavajra · KAL-EE3 series
- Maximum current / voltage range
- 600 A to 3000 A (flexible) (see variants)
- Measurement
- Capacitance
- Display count
- 10000
- Accuracy
- 1%
- Safety rating
- CAT IV 600 V
Lead time 3-7 days · Warranty 3 years limited · MOQ 1 nos
Multimeters, clamp meters & insulation testersSudarshanmark4 variants
SampleMultimeters, clamp meters & insulation testers Sudarshanmark · SUD-4D1 series
- Maximum current / voltage range
- 1500 A to 1000 V DC (see variants)
- Measurement
- Voltage
- Display count
- 6000
- Accuracy
- 0.5%
- Safety rating
- CAT IV 600 V
Lead time 3-7 days · Warranty 12 months from supply · MOQ 1 nos
I-V curve tracers & EL testers (solar)Pallavasamarth3 variants
SampleI-V curve tracers & EL testers (solar) Pallavasamarth · PAL-6D9 series
- Max DC voltage / current
- 1500 V 20 A to EL camera 10 MP (see variants)
- Measurement
- I-V curve
- Irradiance sensor
- Reference cell
- Temperature sensor
- PT1000 cell
- Accuracy
- +/-0.5%
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 5 nos