Sahyadriagni · SAH-135 series

Rating
1000 kW to 5000 kW (see variants)
Output voltage
11 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 14-18 weeks · Warranty 24 months from commissioning · MOQ 10 nos

Price for verified buyers

by Sahyadriagni Power Quality (Sample) · invoiced by BARREL

Request quote

Cascaded H-bridge MV drive, Eco series

SampleMedium-voltage drives

Pennar · PEN-7D8 series

Rating
1000 kW to 8000 kW (see variants)
Output voltage
3.3 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 22-30 weeks · Warranty 24 months from commissioning · MOQ 5 nos

Price for verified buyers

by Pennar Power Quality (Sample) · invoiced by BARREL

Request quote

Kamrupanant · KAM-AB6 series

Rating
1000 kW to 8000 kW (see variants)
Output voltage
11 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 22-30 weeks · Warranty 24 months from commissioning · MOQ 1 nos

Price for verified buyers

by Kamrupanant Power Quality (Sample) · invoiced by BARREL

Request quote

Prakashtek · PRA-132 series

Rating
1000 kW to 5000 kW (see variants)
Output voltage
6.6 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 22-30 weeks · Warranty 24 months from commissioning · MOQ 1 nos

Price for verified buyers

by Prakashtek Power Electronics (Sample) · invoiced by BARREL

Request quote

Konark · KON-ED8 series

Rating
2000 kW to 8000 kW (see variants)
Output voltage
11 kV
Topology
Cascaded H-bridge
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 14-18 weeks · Warranty 36 months from supply · MOQ 1 nos

Price for verified buyers

by Konark Power Quality (Sample) · invoiced by BARREL

Request quote

Cascaded H-bridge MV drive, Duo 4 series

SampleMedium-voltage drives

Kamrupanant · KAM-7D6 series

Rating
1000 kW to 8000 kW (see variants)
Output voltage
6.6 kV
Topology
Cascaded H-bridge
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 14-18 weeks · Warranty 24 months from commissioning · MOQ 10 nos

Price for verified buyers

by Kamrupanant Power Quality (Sample) · invoiced by BARREL

Request quote

Shivaliklumen · SHI-784 series

Rating
3500 kW to 8000 kW (see variants)
Output voltage
6.6 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 22-30 weeks · Warranty 24 months from commissioning · MOQ 2 nos

Price for verified buyers

by Shivaliklumen Drives & Controls (Sample) · invoiced by BARREL

Request quote

Vaigai · VAI-AB5 series

Rating
200 kW to 3500 kW (see variants)
Output voltage
11 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 22-30 weeks · Warranty 36 months from supply · MOQ 5 nos

Price for verified buyers

by Vaigai Power Electronics (Sample) · invoiced by BARREL

Request quote

Doaba · DOA-134 series

Rating
1000 kW to 5000 kW (see variants)
Output voltage
11 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 22-30 weeks · Warranty 36 months from supply · MOQ 10 nos

Price for verified buyers

by Doaba Drives & Controls (Sample) · invoiced by BARREL

Request quote

Teesta · TEE-137 series

Rating
500 kW to 8000 kW (see variants)
Output voltage
3.3 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 22-30 weeks · Warranty 36 months from supply · MOQ 2 nos

Price for verified buyers

by Teesta Power Electronics (Sample) · invoiced by BARREL

Request quote

Doaba · DOA-AB4 series

Rating
3500 kW to 8000 kW (see variants)
Output voltage
11 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 14-18 weeks · Warranty 36 months from supply · MOQ 10 nos

Price for verified buyers

by Doaba Drives & Controls (Sample) · invoiced by BARREL

Request quote

Cascaded H-bridge MV drive, Eco series

SampleMedium-voltage drives

Mahanadi · MAH-7D9 series

Rating
500 kW to 8000 kW (see variants)
Output voltage
6.6 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 22-30 weeks · Warranty 36 months from supply · MOQ 1 nos

Price for verified buyers

by Mahanadi Power Electronics (Sample) · invoiced by BARREL

Request quote

Cascaded H-bridge MV drive, Pro 4 series

SampleMedium-voltage drives

Beas · BEA-7D7 series

Rating
1000 kW to 3500 kW (see variants)
Output voltage
11 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 22-30 weeks · Warranty 24 months from commissioning · MOQ 1 nos

Price for verified buyers

by Beas Power Electronics (Sample) · invoiced by BARREL

Request quote

Prakashtek · PRA-AB4 series

Rating
500 kW to 3500 kW (see variants)
Output voltage
6.6 kV
Topology
NPC 3-level
Input harmonics
Below IEEE 519 (18/24/36-pulse)
Power factor
> 0.95 at full speed range

Lead time 14-18 weeks · Warranty 24 months from commissioning · MOQ 5 nos

Price for verified buyers

by Prakashtek Power Electronics (Sample) · invoiced by BARREL

Request quote