Detuned & series reactorsVidarbhaojas4 variants
SampleDetuned & series reactors Vidarbhaojas · VID-364 series
- Rating
- 10 kVAr to 100 kVAr (see variants)
- Detuning factor
- 5.67% (210 Hz)
- Rated voltage
- 11 kV
- Core
- CRGO silicon steel, gapped
- Winding
- Copper
Lead time 2-3 weeks · Warranty 12 months from commissioning · MOQ 1 nos
VFDs & soft startersKavachline4 variants
SampleVFDs & soft starters Kavachline · KAV-346 series
- Rating
- 5.5 kW to 75 kW (see variants)
- Input voltage
- 3-ph 690 V
- Control mode
- Closed loop vector
- Overload
- 150% 60 s (constant torque)
- Protection class
- IP20
Lead time 1-2 weeks · Warranty 18 months from commissioning · MOQ 1 nos
Voltage stabilisersKalingasarvam6 variants
SampleVoltage stabilisers Kalingasarvam · KAL-874 series
- Rating
- 25 kVA to 1000 kVA (see variants)
- Input range
- 300-460 V
- Output voltage
- 415 V ±3%
- Phases
- 1-ph
- Correction speed
- 25 V/s
Lead time 3-5 weeks · Warranty 12 months from supply · MOQ 5 nos
Capacitor banks & APFCKalingasarvam3 variants
SampleCapacitor banks & APFC Kalingasarvam · KAL-976 series
- Rating
- 100 kVAr to 300 kVAr (see variants)
- Rated voltage
- 415 V
- Capacitor type
- Gas-filled cylindrical
- Switching
- Contactor
- Detuning
- None
Lead time 4-6 weeks · Warranty 18 months from supply · MOQ 2 nos
STATCOM & SVGKalingasarvam4 variants
Kalingasarvam · KAL-243 series
- Rating
- 200 kVAr to 3 MVAr (see variants)
- Voltage
- 690 V
- Topology
- 3-level IGBT
- Response time
- < 5 ms
- Compensation
- Capacitive and inductive, bidirectional
Lead time 8-12 weeks · Warranty 24 months from commissioning · MOQ 2 nos
Active harmonic filtersVidarbhaojas4 variants
SampleActive harmonic filters Vidarbhaojas · VID-F57 series
- Compensation current
- 75 A to 200 A (see variants)
- Voltage
- 3-ph 415 V
- Wires
- 3-wire
- Harmonic order
- 2nd to 50th
- Response time
- < 20 ms
Lead time 3-4 weeks · Warranty 24 months from commissioning · MOQ 10 nos
Active harmonic filtersTeesta6 variants
SampleActive harmonic filters Teesta · TEE-FF5 series
- Compensation current
- 50 A to 300 A (see variants)
- Voltage
- 3-ph 415 V
- Wires
- 4-wire
- Harmonic order
- 2nd to 50th
- Response time
- < 20 ms
Lead time 3-4 weeks · Warranty 24 months from commissioning · MOQ 10 nos
Detuned & series reactorsSahyadriagni3 variants
SampleDetuned & series reactors Sahyadriagni · SAH-7D3 series
- Rating
- 25 kVAr to 100 kVAr (see variants)
- Detuning factor
- 14% (134 Hz)
- Rated voltage
- 415 V
- Core
- Air core
- Winding
- Copper
Lead time 2-3 weeks · Warranty 12 months from commissioning · MOQ 10 nos
Harmonic filtersSahyadriojas3 variants
Sahyadriojas · SAH-097 series
- Filter rating
- 100 kVAr to 300 kVAr (see variants)
- Tuned to
- 7th
- Voltage
- 11 kV
- Reactor core
- Air core (HV)
- Reactor insulation
- Class H
Lead time 3-4 weeks · Warranty 12 months from commissioning · MOQ 1 nos
Harmonic filtersBundel5 variants
Bundel · BUN-6A5 series
- Filter rating
- 25 kVAr to 300 kVAr (see variants)
- Tuned to
- 4.7th (235 Hz)
- Voltage
- 440 V
- Reactor core
- CRGO laminated
- Reactor insulation
- Class H
Lead time 6-8 weeks · Warranty 12 months from commissioning · MOQ 1 nos
STATCOM & SVGMahanadi6 variants
Mahanadi · MAH-242 series
- Rating
- 200 kVAr to 25 MVAr (see variants)
- Voltage
- 690 V
- Topology
- 3-level IGBT
- Response time
- < 5 ms
- Compensation
- Capacitive and inductive, bidirectional
Lead time 8-12 weeks · Warranty 24 months from commissioning · MOQ 10 nos
Medium-voltage drivesTungabhadrasamarth5 variants
SampleMedium-voltage drives Tungabhadrasamarth · TUN-AB9 series
- Rating
- 200 kW to 3500 kW (see variants)
- Output voltage
- 11 kV
- Topology
- Cascaded H-bridge
- Input harmonics
- Below IEEE 519 (18/24/36-pulse)
- Power factor
- > 0.95 at full speed range
Lead time 22-30 weeks · Warranty 36 months from supply · MOQ 1 nos
Servo stabilisers & isolation transformersSahyadriojas4 variants
SampleServo stabilisers & isolation transformers Sahyadriojas · SAH-0B2 series
- Rating
- 10 kVA to 100 kVA (see variants)
- Primary voltage
- 380-440 V
- Secondary voltage
- 415 V
- Phases
- 3-ph
- Winding
- Aluminium
Lead time 4-6 weeks · Warranty 24 months from supply · MOQ 5 nos
Detuned & series reactorsDeccan6 variants
SampleDetuned & series reactors Deccan · DEC-369 series
- Rating
- 10 kVAr to 400 kVAr (see variants)
- Detuning factor
- 7% (189 Hz)
- Rated voltage
- 440 V
- Core
- Air core
- Winding
- Copper
Lead time 2-3 weeks · Warranty 12 months from commissioning · MOQ 1 nos
Harmonic filtersKonark6 variants
Konark · KON-586 series
- Filter rating
- 25 kVAr to 500 kVAr (see variants)
- Tuned to
- 4.7th (235 Hz)
- Voltage
- 415 V
- Reactor core
- CRGO laminated
- Reactor insulation
- Class H
Lead time 6-8 weeks · Warranty 24 months from supply · MOQ 5 nos
Servo stabilisers & isolation transformersShivalik3 variants
SampleServo stabilisers & isolation transformers Shivalik · SHI-473 series
- Rating
- 10 kVA to 50 kVA (see variants)
- Primary voltage
- 380-440 V
- Secondary voltage
- 415 V
- Phases
- 3-ph
- Winding
- Aluminium
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 1 nos
Detuned & series reactorsPennar4 variants
SampleDetuned & series reactors Pennar · PEN-B58 series
- Rating
- 10 kVAr to 100 kVAr (see variants)
- Detuning factor
- 5.67% (210 Hz)
- Rated voltage
- 525 V
- Core
- Air core
- Winding
- Aluminium
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 5 nos
Detuned & series reactorsVindhyaurja3 variants
SampleDetuned & series reactors Vindhyaurja · VIN-3A2 series
- Rating
- 50 kVAr to 200 kVAr (see variants)
- Detuning factor
- 5.67% (210 Hz)
- Rated voltage
- 11 kV
- Core
- Air core
- Winding
- Aluminium
Lead time 2-3 weeks · Warranty 18 months from supply · MOQ 2 nos
Capacitor banks & APFCBundel4 variants
SampleCapacitor banks & APFC Bundel · BUN-AF7 series
- Rating
- 25 kVAr to 200 kVAr (see variants)
- Rated voltage
- 440 V
- Capacitor type
- Self-healing dry
- Switching
- Thyristor
- Detuning
- 5.67% (210 Hz)
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 1 nos
STATCOM & SVGPennar5 variants
Pennar · PEN-846 series
- Rating
- 100 kVAr to 3 MVAr (see variants)
- Voltage
- 33 kV
- Topology
- Cascaded H-bridge (MV)
- Response time
- < 10 ms
- Compensation
- Capacitive and inductive, bidirectional
Lead time 16-24 weeks · Warranty 24 months from commissioning · MOQ 2 nos
Medium-voltage drivesSahyadriagni4 variants
SampleMedium-voltage drives Sahyadriagni · SAH-782 series
- Rating
- 500 kW to 3500 kW (see variants)
- Output voltage
- 11 kV
- Topology
- NPC 3-level
- Input harmonics
- Below IEEE 519 (18/24/36-pulse)
- Power factor
- > 0.95 at full speed range
Lead time 22-30 weeks · Warranty 24 months from commissioning · MOQ 1 nos
VFDs & soft startersKanchi6 variants
SampleVFDs & soft starters Kanchi · KAN-342 series
- Rating
- 5.5 kW to 250 kW (see variants)
- Input voltage
- 3-ph 690 V
- Control mode
- V/f
- Overload
- 150% 60 s (constant torque)
- Protection class
- IP20
Lead time 1-2 weeks · Warranty 18 months from commissioning · MOQ 1 nos
STATCOM & SVGPennar4 variants
Pennar · PEN-242 series
- Rating
- 100 kVAr to 1 MVAr (see variants)
- Voltage
- 690 V
- Topology
- 3-level IGBT
- Response time
- < 5 ms
- Compensation
- Capacitive and inductive, bidirectional
Lead time 16-24 weeks · Warranty 36 months with AMC · MOQ 1 nos
Harmonic filtersKamrupanant5 variants
Kamrupanant · KAM-581 series
- Filter rating
- 50 kVAr to 500 kVAr (see variants)
- Tuned to
- Broadband
- Voltage
- 11 kV
- Reactor core
- Air core (HV)
- Reactor insulation
- Class H
Lead time 6-8 weeks · Warranty 24 months from supply · MOQ 2 nos