Fuel oil & firing systemsTaptiakshay3 variants
SampleFuel oil & firing systems Taptiakshay · TAP-CD3 series
- Burner capacity
- 2000 kg/h to 6000 kg/h (see variants)
- Fuel
- Gas
- Atomisation
- Steam
- Turndown
- 6:1
- Heater
- Electric
Lead time 6-10 weeks · Warranty 12 months · MOQ 1 set
Cooling towersShivaliklumen5 variants
Shivaliklumen · SHI-DA7 series
- Flow rate
- 500 m3/h to 10000 m3/h (see variants)
- Tower type
- Natural draft
- Construction
- RCC
- Fill type
- PVC film
- Range
- 10 C
Lead time 16-24 weeks · Warranty 24 months on FRP parts · MOQ 10 nos
Feed-water pumps & heatersTaxiladhruv4 variants
SampleFeed-water pumps & heaters Taxiladhruv · TAX-5A5 series
- Flow capacity
- 20 m3/h to 250 m3/h (see variants)
- Equipment
- Deaerator
- Discharge pressure
- 110 bar
- Stages
- 6
- Casing
- Segmental ring-section
Lead time 10-14 weeks · Warranty 18 months · MOQ 1 nos
Steam turbines & condensersNarmada4 variants
SampleSteam turbines & condensers Narmada · NAR-225 series
- Output
- 5 MW to 60 MW (see variants)
- Turbine type
- Extraction
- Inlet steam
- 45 ata / 440 C
- Speed
- 3000 rpm
- Exhaust pressure
- 3.5 ata
Lead time 8-12 months · Warranty 18 months · MOQ 2 nos
Steam turbines & condensersTaxiladhruv5 variants
SampleSteam turbines & condensers Taxiladhruv · TAX-0C1 series
- Output
- 5 MW to 120 MW (see variants)
- Turbine type
- Back-pressure
- Inlet steam
- 67 ata / 485 C
- Speed
- 5500 rpm with gearbox
- Exhaust pressure
- 3.5 ata
Lead time 14-20 months · Warranty 18 months · MOQ 1 nos
Steam turbines & condensersMagadhsetu3 variants
SampleSteam turbines & condensers Magadhsetu · MAG-225 series
- Output
- 60 MW to 250 MW (see variants)
- Turbine type
- Back-pressure
- Inlet steam
- 67 ata / 485 C
- Speed
- 3000 rpm
- Exhaust pressure
- 3.5 ata
Lead time 14-20 months · Warranty 18 months · MOQ 5 nos
Steam turbines & condensersRavi6 variants
SampleSteam turbines & condensers Ravi · RAV-B66 series
- Output
- 1 MW to 120 MW (see variants)
- Turbine type
- Extraction
- Inlet steam
- 67 ata / 485 C
- Speed
- 3000 rpm
- Exhaust pressure
- 0.1 ata
Lead time 8-12 months · Warranty 18 months · MOQ 5 nos
Steam turbines & condensersTaxiladhruv3 variants
SampleSteam turbines & condensers Taxiladhruv · TAX-0C3 series
- Output
- 1 MW to 12 MW (see variants)
- Turbine type
- Condensing
- Inlet steam
- 45 ata / 440 C
- Speed
- 3000 rpm
- Exhaust pressure
- 8 ata
Lead time 14-20 months · Warranty 18 months · MOQ 1 nos
Boilers & HRSGShaktimark4 variants
Shaktimark · SHA-193 series
- Steam capacity
- 150 TPH to 1100 TPH (see variants)
- Boiler type
- PC
- Steam pressure
- 45 bar
- Steam temperature
- 540 C
- Fuel
- Biomass
Lead time 18-26 months · Warranty 18 months from commissioning · MOQ 5 nos
Steam turbines & condensersSahyadri6 variants
SampleSteam turbines & condensers Sahyadri · SAH-0C3 series
- Output
- 5 MW to 250 MW (see variants)
- Turbine type
- Extraction
- Inlet steam
- 67 ata / 485 C
- Speed
- 3000 rpm
- Exhaust pressure
- 8 ata
Lead time 8-12 months · Warranty 18 months · MOQ 10 nos
Feed-water pumps & heatersCoorgshakti6 variants
SampleFeed-water pumps & heaters Coorgshakti · COO-D35 series
- Flow capacity
- 20 m3/h to 800 m3/h (see variants)
- Equipment
- Deaerator
- Discharge pressure
- 60 bar
- Stages
- 12
- Casing
- Segmental ring-section
Lead time 20-30 weeks · Warranty 18 months · MOQ 1 nos
Steam turbines & condensersTeestakiran3 variants
SampleSteam turbines & condensers Teestakiran · TEE-AD8 series
- Output
- 30 MW to 120 MW (see variants)
- Turbine type
- Extraction
- Inlet steam
- 130 ata / 535 C
- Speed
- 5500 rpm with gearbox
- Exhaust pressure
- 3.5 ata
Lead time 8-12 months · Warranty 18 months · MOQ 1 nos
Cooling towersCoorgshakti6 variants
Coorgshakti · COO-DA1 series
- Flow rate
- 500 m3/h to 20000 m3/h (see variants)
- Tower type
- Natural draft
- Construction
- Pressure-treated wood
- Fill type
- PVC film
- Range
- 8 C
Lead time 16-24 weeks · Warranty 24 months on FRP parts · MOQ 10 nos
Cooling towersNarmada4 variants
Narmada · NAR-DA4 series
- Flow rate
- 2500 m3/h to 20000 m3/h (see variants)
- Tower type
- Natural draft
- Construction
- FRP
- Fill type
- Splash
- Range
- 10 C
Lead time 8-12 weeks · Warranty 24 months on FRP parts · MOQ 1 nos
Feed-water pumps & heatersMunnarloha3 variants
SampleFeed-water pumps & heaters Munnarloha · MUN-5A3 series
- Flow capacity
- 20 m3/h to 100 m3/h (see variants)
- Equipment
- BFP
- Discharge pressure
- 200 bar
- Stages
- 8
- Casing
- Barrel type
Lead time 20-30 weeks · Warranty 18 months · MOQ 1 nos
Boilers & HRSGMunnarloha3 variants
Munnarloha · MUN-474 series
- Steam capacity
- 35 TPH to 150 TPH (see variants)
- Boiler type
- PC
- Steam pressure
- 170 bar
- Steam temperature
- 565 C
- Fuel
- Biomass
Lead time 10-14 months · Warranty 12 months · MOQ 1 nos
Feed-water pumps & heatersRavi4 variants
SampleFeed-water pumps & heaters Ravi · RAV-5A1 series
- Flow capacity
- 50 m3/h to 500 m3/h (see variants)
- Equipment
- BFP
- Discharge pressure
- 110 bar
- Stages
- 6
- Casing
- Segmental ring-section
Lead time 10-14 weeks · Warranty 12 months · MOQ 1 nos
Steam turbines & condensersPataliputra4 variants
SampleSteam turbines & condensers Pataliputra · PAT-D17 series
- Output
- 1 MW to 30 MW (see variants)
- Turbine type
- Condensing
- Inlet steam
- 130 ata / 535 C
- Speed
- 5500 rpm with gearbox
- Exhaust pressure
- 3.5 ata
Lead time 14-20 months · Warranty 18 months · MOQ 5 nos
Steam turbines & condensersCholaprithvi4 variants
SampleSteam turbines & condensers Cholaprithvi · CHO-AD4 series
- Output
- 30 MW to 250 MW (see variants)
- Turbine type
- Condensing
- Inlet steam
- 45 ata / 440 C
- Speed
- 5500 rpm with gearbox
- Exhaust pressure
- 0.1 ata
Lead time 14-20 months · Warranty 18 months · MOQ 5 nos
Boiler & turbine sparesTeestakiran5 variants
SampleBoiler & turbine spares Teestakiran · TEE-A79 series
- Unit size
- 30 MW to 500 MW (see variants)
- Component
- Turbine blades
- Tube material
- SA 210 A1
- Blade material
- 12Cr
- OEM compatibility
- Alstom type
Lead time 12-20 weeks · Warranty 18 months · MOQ 1 set
Coal & ash handling plantTeestakiran4 variants
SampleCoal & ash handling plant Teestakiran · TEE-E23 series
- Handling capacity
- 600 TPH to 4800 TPH (see variants)
- Equipment
- Ash slurry system
- Belt width
- 1400 mm
- Belt speed
- 3.15 m/s
- Belt grade
- Fire-resistant ST
Lead time 12-18 months · Warranty 12 months · MOQ 5 lot
Coal & ash handling plantPataliputraneel5 variants
SampleCoal & ash handling plant Pataliputraneel · PAT-2D2 series
- Handling capacity
- 100 TPH to 2400 TPH (see variants)
- Equipment
- Belt conveyor
- Belt width
- 650 mm
- Belt speed
- 1.6 m/s
- Belt grade
- Fire-resistant ST
Lead time 12-18 months · Warranty 12 months · MOQ 1 lot
Boiler & turbine sparesMunnarloha6 variants
SampleBoiler & turbine spares Munnarloha · MUN-F05 series
- Unit size
- 10 MW to 500 MW (see variants)
- Component
- Superheater
- Tube material
- SA 210 A1
- Blade material
- 17-4 PH
- OEM compatibility
- BHEL type
Lead time 4-8 weeks · Warranty 12 months · MOQ 1 set
Cooling towersSahyadri6 variants
Sahyadri · SAH-668 series
- Flow rate
- 500 m3/h to 20000 m3/h (see variants)
- Tower type
- Crossflow
- Construction
- RCC
- Fill type
- PVC film
- Range
- 8 C
Lead time 16-24 weeks · Warranty 24 months on FRP parts · MOQ 10 nos