Distribution transformer monitoring units (DTMU)Kalinga5 variants
SampleDistribution transformer monitoring units (DTMU) Kalinga · KAL-B82 series
- DT rating covered
- Up to 63 kVA to 1250-2000 kVA (see variants)
- Measurement
- V, I, kW, kVA, PF, THD
- Accuracy class
- 0.5S
- CT input
- Split-core CT 100/5 A
- Communication
- NB-IoT
Lead time 3-4 weeks · Warranty 24 months from supply · MOQ 1 nos
Data loggersKalinga3 variants
Kalinga · KAL-374 series
- Channels
- 8 channels to 32 channels (see variants)
- Input types
- Thermocouple K/J
- Resolution
- 16-bit
- Sampling rate
- 100 ms min
- Memory
- 8 GB
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 5 nos
Prepaid metering systemsMagadh6 variants
SamplePrepaid metering systems Magadh · MAG-6F4 series
- Meter type
- 1-ph 5-30 A to Split 1-ph with CIU (see variants)
- Accuracy class
- 1.0
- Communication
- NB-IoT
- Protocol
- DLMS/COSEM
- Disconnect relay
- Internal 200 A (3-ph)
Lead time 3-4 weeks · Warranty 5 years from supply · MOQ 1 nos
Power quality analysersKanchi5 variants
SamplePower quality analysers Kanchi · KAN-CA9 series
- Type
- Panel meter Class S to Fixed PQ monitor Class A (see variants)
- Measurement class
- Class A
- Voltage input
- 57-690 V L-L
- Current input
- Rogowski coil
- Harmonics
- Up to 63rd
Lead time 2-4 weeks · Warranty 24 months from supply · MOQ 1 nos
Distribution transformer monitoring units (DTMU)Hoysala5 variants
SampleDistribution transformer monitoring units (DTMU) Hoysala · HOY-408 series
- DT rating covered
- Up to 63 kVA to 1250-2000 kVA (see variants)
- Measurement
- V, I, kW, kVA, PF, THD
- Accuracy class
- 0.5S
- CT input
- Split-core CT 100/5 A
- Communication
- GPRS/4G
Lead time 6-8 weeks · Warranty 24 months from supply · MOQ 10 nos
IoT & remote monitoringHampi5 variants
SampleIoT & remote monitoring Hampi · HAM-996 series
- Channels / points
- 8 inputs to 128 inputs (see variants)
- Connectivity
- LoRaWAN
- Protocols
- MQTT
- Serial ports
- 2 x RS-485 + 1 RS-232
- Digital I/O
- 4 DI / 2 DO
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 1 nos
IoT & remote monitoringKonkan4 variants
SampleIoT & remote monitoring Konkan · KON-991 series
- Channels / points
- 16 inputs to 128 inputs (see variants)
- Connectivity
- Ethernet + 4G
- Protocols
- IEC 60870-5-104
- Serial ports
- 1 x RS-485
- Digital I/O
- 8 DI / 4 DO
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 5 nos
Prepaid metering systemsPennar6 variants
SamplePrepaid metering systems Pennar · PEN-6C5 series
- Meter type
- 1-ph 5-30 A to Split 1-ph with CIU (see variants)
- Accuracy class
- 1.0
- Communication
- NB-IoT
- Protocol
- DLMS/COSEM
- Disconnect relay
- Internal 200 A (3-ph)
Lead time 3-4 weeks · Warranty 7 years from supply · MOQ 10 nos
Energy meters (smart, ABT, net)Faradayline4 variants
SampleEnergy meters (smart, ABT, net) Faradayline · FAR-5C5 series
- Meter type
- 1-ph smart 5-30 A to 3-ph HT 3P4W 1 A (see variants)
- Accuracy class
- 0.2S
- Reference voltage
- 3x240/415 V
- Frequency
- 50 Hz
- Communication
- RF mesh
Lead time 2-3 weeks · Warranty 60 months from installation · MOQ 2 nos
Prepaid metering systemsPrabhacore4 variants
SamplePrepaid metering systems Prabhacore · PRA-6C5 series
- Meter type
- 1-ph 10-60 A to 3-ph HT CT-operated (see variants)
- Accuracy class
- 0.5S
- Communication
- NB-IoT
- Protocol
- DLMS/COSEM
- Disconnect relay
- Internal 200 A (3-ph)
Lead time 3-4 weeks · Warranty 5 years from supply · MOQ 1 nos
Power quality analysersVaigaispark3 variants
SamplePower quality analysers Vaigaispark · VAI-C06 series
- Type
- Panel meter Class A to Portable 3-ph Class A (see variants)
- Measurement class
- Class A
- Voltage input
- Up to 1000 V CAT III
- Current input
- Clamp CT 5-3000 A
- Harmonics
- Up to 50th
Lead time 2-4 weeks · Warranty 36 months from supply · MOQ 1 nos
IoT & remote monitoringAiravatmax6 variants
SampleIoT & remote monitoring Airavatmax · AIR-991 series
- Channels / points
- 8 inputs to 256 inputs (see variants)
- Connectivity
- LoRaWAN
- Protocols
- Modbus RTU/TCP
- Serial ports
- 1 x RS-485
- Digital I/O
- 4 DI / 2 DO
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
Distribution transformer monitoring units (DTMU)Hampi5 variants
SampleDistribution transformer monitoring units (DTMU) Hampi · HAM-402 series
- DT rating covered
- Up to 63 kVA to 1250-2000 kVA (see variants)
- Measurement
- V, I, kW, kVA, PF, THD
- Accuracy class
- 1.0
- CT input
- Split-core CT 100/5 A
- Communication
- RF mesh
Lead time 6-8 weeks · Warranty 24 months from supply · MOQ 2 nos
Data loggersHoysala3 variants
Hoysala · HOY-FA6 series
- Channels
- 16 channels to 64 channels (see variants)
- Input types
- Modbus RTU
- Resolution
- 16-bit
- Sampling rate
- 100 ms min
- Memory
- 8 GB
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
Distribution transformer monitoring units (DTMU)Vaigaishakti4 variants
SampleDistribution transformer monitoring units (DTMU) Vaigaishakti · VAI-2A7 series
- DT rating covered
- 100-200 kVA to 1250-2000 kVA (see variants)
- Measurement
- V, I, kW, kVA, PF, THD
- Accuracy class
- 1.0
- CT input
- Split-core CT 600/5 A
- Communication
- NB-IoT
Lead time 3-4 weeks · Warranty 36 months from supply · MOQ 1 nos
IoT & remote monitoringOjascore6 variants
SampleIoT & remote monitoring Ojascore · OJA-C93 series
- Channels / points
- 8 inputs to 256 inputs (see variants)
- Connectivity
- Ethernet + 4G
- Protocols
- OPC UA
- Serial ports
- 2 x RS-485 + 1 RS-232
- Digital I/O
- 4 DI / 2 DO
Lead time 3-4 weeks · Warranty 24 months from supply · MOQ 1 nos
Prepaid metering systemsOjascore5 variants
SamplePrepaid metering systems Ojascore · OJA-6F6 series
- Meter type
- 1-ph 5-30 A to 3-ph HT CT-operated (see variants)
- Accuracy class
- 0.5S
- Communication
- GPRS/4G
- Protocol
- IS 15959 Part 2
- Disconnect relay
- Internal 100 A
Lead time 6-8 weeks · Warranty 7 years from supply · MOQ 1 nos
Data loggersChambal5 variants
Chambal · CHA-373 series
- Channels
- 4 channels to 64 channels (see variants)
- Input types
- PT100
- Resolution
- 16-bit
- Sampling rate
- 100 ms min
- Memory
- 32 GB
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 10 nos
Weather monitoring stationsPennar5 variants
SampleWeather monitoring stations Pennar · PEN-424 series
- Configuration
- Basic: GHI + ambient temp to Wind mast 40 m (see variants)
- Pyranometer class
- ISO 9060 Class B
- Wind sensor
- Ultrasonic 2D
- Temperature sensor
- PT100 class A
- Humidity range
- 0-100% RH
Lead time 6-8 weeks · Warranty 24 months from commissioning · MOQ 1 set
Energy meters (smart, ABT, net)Vaigaispark6 variants
SampleEnergy meters (smart, ABT, net) Vaigaispark · VAI-053 series
- Meter type
- 1-ph smart 5-30 A to ABT 0.2S 3P3W (see variants)
- Accuracy class
- 0.2S
- Reference voltage
- 3x240/415 V
- Frequency
- 50 Hz
- Communication
- RS-485 Modbus
Lead time 4-6 weeks · Warranty 60 months from installation · MOQ 2 nos
Prepaid metering systemsBeas5 variants
SamplePrepaid metering systems Beas · BEA-F05 series
- Meter type
- 1-ph 5-30 A to 3-ph HT CT-operated (see variants)
- Accuracy class
- 0.5S
- Communication
- GPRS/4G
- Protocol
- IS 15959 Part 2
- Disconnect relay
- Internal 200 A (3-ph)
Lead time 3-4 weeks · Warranty 5 years from supply · MOQ 2 nos
IoT & remote monitoringVaigaishakti6 variants
SampleIoT & remote monitoring Vaigaishakti · VAI-C93 series
- Channels / points
- 8 inputs to 256 inputs (see variants)
- Connectivity
- 4G LTE Cat 1
- Protocols
- OPC UA
- Serial ports
- 2 x RS-485 + 1 RS-232
- Digital I/O
- 8 DI / 4 DO
Lead time 1-2 weeks · Warranty 24 months from supply · MOQ 1 nos
IoT & remote monitoringAwadh3 variants
SampleIoT & remote monitoring Awadh · AWA-B03 series
- Channels / points
- 64 inputs to 256 inputs (see variants)
- Connectivity
- Ethernet + 4G
- Protocols
- Modbus RTU/TCP
- Serial ports
- 1 x RS-485
- Digital I/O
- 8 DI / 4 DO
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
Energy meters (smart, ABT, net)Magadh3 variants
SampleEnergy meters (smart, ABT, net) Magadh · MAG-5C1 series
- Meter type
- 3-ph LTCT 5 A to ABT 0.2S 3P4W (see variants)
- Accuracy class
- 1.0
- Reference voltage
- 3x63.5/110 V
- Frequency
- 50 Hz
- Communication
- Optical port + NIC
Lead time 4-6 weeks · Warranty 5 years from supply · MOQ 2 nos