Concrete batching & transit mixersBrahmaputraakash3 variants
SampleFor rentConcrete batching & transit mixers Brahmaputraakash · BRA-7B9 series
- Output capacity
- Mobile mixer 3 cu m to Batching plant 30 cu m/h (see variants)
- Drum capacity
- 9 cu m
- Type
- Transit mixer
- Operator
- Not included
- Fuel
- Included
Lead time 1 week · Warranty Breakdown replacement within 48 h · MOQ 1 nos
Trenchers & HDD rigsFluxmax6 variants
SampleFor rentTrenchers & HDD rigs Fluxmax · FLU-A09 series
- Machine size
- Trencher 300 mm wide to HDD 40 t (see variants)
- Trench depth
- 2.0 m
- Bore diameter
- Up to 200 mm
- Bore length
- Up to 150 m
- Operator
- Included
Lead time 1-2 weeks · Warranty Breakdown replacement within 72 h · MOQ 1 nos
Cable fault locatorsPushpakline6 variants
SampleCable fault locators Pushpakline · PUS-684 series
- Surge voltage
- 8 kV to 40 kV (see variants)
- Surge energy
- 2000 J
- Methods
- TDR, ARM, Decay
- Cable length range
- Up to 10 km
- Display
- Monochrome
Lead time 3-4 weeks · Warranty 24 months on request · MOQ 2 set
Survey & inspection dronesEllora3 variants
SampleFor rentSurvey & inspection drones Ellora · ELL-FC2 series
- Drone class
- RTK mapping to LiDAR mapping (see variants)
- Sensor
- LiDAR
- Positioning
- RTK
- Flight time
- 90 min
- Pilot
- DGCA pilot plus visual observer
Lead time 1 week · Warranty Re-flight at no charge if data unusable · MOQ 1 nos
Torque wrenches & bolt tensioningMahabaleshwarohm4 variants
SampleTorque wrenches & bolt tensioning Mahabaleshwarohm · MAH-9F9 series
- Torque range
- 20-100 Nm to 500-3000 Nm (see variants)
- Type
- Digital
- Drive size
- 1/2 inch
- Accuracy
- +/-4%
- Length
- 600 mm
Lead time 1-2 weeks · Warranty Re-calibration after 5000 cycles · MOQ 1 set
Concrete batching & transit mixersEllora6 variants
SampleFor rentConcrete batching & transit mixers Ellora · ELL-0D9 series
- Output capacity
- Mobile mixer 3 cu m to Boom pump 60 cu m/h (see variants)
- Drum capacity
- 9 cu m
- Type
- Static pump
- Operator
- Included
- Fuel
- Included
Lead time 1 week · Warranty Breakdown replacement within 48 h · MOQ 1 nos
CT/PT & transformer analysersAwadh6 variants
SampleCT/PT & transformer analysers Awadh · AWA-076 series
- Test channels / output
- Single channel 2 kV to Multi-function 60 A (see variants)
- Tests
- Winding resistance
- Class tested
- Class 0.2 to 5P
- Output current
- 0-30 A
- Output voltage
- 0-250 V
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 1 nos
Stringing machinesTeesta5 variants
Teesta · TEE-BB7 series
- Maximum tension
- 15 kN to 100 kN (see variants)
- Type
- Puller
- Drive
- Electric
- Bullwheel diameter
- 1500 mm
- Conductor size
- Twin Moose
Lead time 10-14 weeks · Warranty 12 months from commissioning · MOQ 2 nos
SFRA, winding resistance & turns-ratio testersShivalik6 variants
SampleSFRA, winding resistance & turns-ratio testers Shivalik · SHI-9D7 series
- Test current / range
- 1 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- SFRA
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 2 nos
Earth & soil resistivity testersKamrupsamarth4 variants
SampleEarth & soil resistivity testers Kamrupsamarth · KAM-414 series
- Measuring range
- 0-200 ohm to 0-30 kohm (see variants)
- Method
- Clamp-on
- Test frequency
- 128 Hz
- Test current
- Up to 20 mA
- Accuracy
- +/-2%
Lead time 3-4 weeks · Warranty 24 months with calibration · MOQ 2 nos
Earth & soil resistivity testersKamrupphase5 variants
SampleEarth & soil resistivity testers Kamrupphase · KAM-E98 series
- Measuring range
- 0-20 ohm to 0-30 kohm (see variants)
- Method
- Clamp-on
- Test frequency
- 128 Hz
- Test current
- Up to 20 mA
- Accuracy
- +/-2%
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 2 nos
SFRA, winding resistance & turns-ratio testersDeccan5 variants
SampleSFRA, winding resistance & turns-ratio testers Deccan · DEC-9D2 series
- Test current / range
- 1 A winding resistance to TTR 0.8-10000 (see variants)
- Instrument
- Turns ratio
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
Drilling & core cuttingTeesta3 variants
SampleDrilling & core cutting Teesta · TEE-803 series
- Maximum drill / core diameter
- 26 mm to 50 mm (see variants)
- Power
- 800 W
- Voltage
- 230 V single phase
- Chuck
- SDS Plus
- Speed
- 1000 rpm
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
Concrete batching & transit mixersKamrup6 variants
SampleFor rentConcrete batching & transit mixers Kamrup · KAM-7B5 series
- Output capacity
- Mobile mixer 3 cu m to Boom pump 60 cu m/h (see variants)
- Drum capacity
- 9 cu m
- Type
- Static pump
- Operator
- Not included
- Fuel
- Included
Lead time 2-3 days · Warranty Breakdown replacement within 48 h · MOQ 1 nos
Live-line & hot-stick toolsMysoresarvam3 variants
SampleLive-line & hot-stick tools Mysoresarvam · MYS-F93 series
- Rated voltage
- 132 kV to 400 kV (see variants)
- Material
- FRP pultruded
- Length
- 4.5 m
- Type
- Telescopic
- Head fittings
- Clamp stick
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 10 nos
Earth & soil resistivity testersSetucore5 variants
SampleEarth & soil resistivity testers Setucore · SET-E93 series
- Measuring range
- 0-20 ohm to 0-30 kohm (see variants)
- Method
- Clamp-on
- Test frequency
- 128 Hz
- Test current
- Up to 20 mA
- Accuracy
- +/-5%
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 1 nos
Cable fault locatorsKamrupphase4 variants
SampleCable fault locators Kamrupphase · KAM-1E9 series
- Surge voltage
- 8 kV to 20 kV (see variants)
- Surge energy
- 1000 J
- Methods
- Pulse echo, ARM, SIM
- Cable length range
- Up to 20 km
- Display
- Colour touch
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 5 set
Thermal camerasDeccan6 variants
Deccan · DEC-D91 series
- Detector resolution
- 80 x 60 to 640 x 480 (see variants)
- Temperature range
- -20 to 650 deg C
- Thermal sensitivity
- Below 0.05 deg C
- Accuracy
- +/-2%
- Focus
- Autofocus
Lead time 1-2 weeks · Warranty 10 years detector warranty (limited) · MOQ 1 nos
Partial discharge & VLF testersMaurya6 variants
SamplePartial discharge & VLF testers Maurya · MAU-335 series
- Test voltage (VLF peak)
- 28 kV to 90 kV (see variants)
- Test frequency
- 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 4-6 weeks · Warranty 24 months with calibration · MOQ 1 set
Torque wrenches & bolt tensioningBrahmaputraurja6 variants
SampleTorque wrenches & bolt tensioning Brahmaputraurja · BRA-9F2 series
- Torque range
- 5-25 Nm to 1000-10000 Nm (see variants)
- Type
- Hydraulic
- Drive size
- 1 inch
- Accuracy
- +/-3%
- Length
- 600 mm
Lead time 3-5 weeks · Warranty Re-calibration after 5000 cycles · MOQ 10 set
Insulated hand tools (1000 V)Teesta6 variants
SampleInsulated hand tools (1000 V) Teesta · TEE-606 series
- Kit size
- 5 pieces to 40 pieces (see variants)
- Rated voltage
- 1500 V DC
- Material
- Chrome molybdenum
- Insulation
- Dual layer injection moulded
- Handle colour
- Orange
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 10 set
CT/PT & transformer analysersKamrupsamarth5 variants
SampleCT/PT & transformer analysers Kamrupsamarth · KAM-516 series
- Test channels / output
- Single channel 2 kV to Multi-function 30 A (see variants)
- Tests
- Winding resistance
- Class tested
- PS class
- Output current
- 0-100 A
- Output voltage
- 0-2000 V
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 1 nos
CT/PT & transformer analysersHoysala4 variants
SampleCT/PT & transformer analysers Hoysala · HOY-092 series
- Test channels / output
- 3-phase 5 kV to Multi-function 60 A (see variants)
- Tests
- Winding resistance
- Class tested
- Class 0.2 to 5P
- Output current
- 0-30 A
- Output voltage
- 0-2000 V
Lead time 6-8 weeks · Warranty 24 months with calibration · MOQ 2 nos
Multimeters, clamp meters & insulation testersBrahmaputra3 variants
SampleMultimeters, clamp meters & insulation testers Brahmaputra · BRA-EE2 series
- Maximum current / voltage range
- 1500 A to 3000 A (flexible) (see variants)
- Measurement
- Voltage
- Display count
- 6000
- Accuracy
- 1%
- Safety rating
- CAT IV 600 V
Lead time 3-7 days · Warranty 3 years limited · MOQ 5 nos