Merchants / MAHABALESHWARJOULE

Mahabaleshwarjoule Enviro Engineers (Sample)

Mahabaleshwarjoule Enviro Engineers India Pvt Ltd (Sample)

Verified by BARREL — PAN, GSTIN and company records checked; NDA and non-circumvention signed

Catalogue · 18 listings

Send an RFQ

Prices are shown to verified buyers. Register your company to see them and request quotes. Questions, quotes, orders and invoices all go through BARREL Shop.

Flue-gas desulphurisation (FGD)

Gypsum dewatering system, Core series

SampleFlue-gas desulphurisation (FGD)

Mahabaleshwarjoule · MAH-237 series

Boiler size
10 MW to 120 MW (see variants)
Technology
Dry sorbent
SO2 removal efficiency
90%
Inlet SO2
Up to 2500 mg/Nm3
Absorber material
Rubber lined carbon steel

Lead time 24-36 weeks · Warranty 24 months performance guarantee · MOQ 2 set

Price for verified buyers

invoiced by BARREL

Request quote

Seawater FGD, Eco 3 series

SampleFlue-gas desulphurisation (FGD)

Mahabaleshwarjoule · MAH-405 series

Boiler size
120 MW to 500 MW (see variants)
Technology
Wet limestone-gypsum
SO2 removal efficiency
90%
Inlet SO2
Up to 2500 mg/Nm3
Absorber material
Rubber lined carbon steel

Lead time 24-36 weeks · Warranty 12 months from commissioning · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

Dry sorbent injection system, Smart series

SampleFlue-gas desulphurisation (FGD)

Mahabaleshwarjoule · MAH-2E3 series

Boiler size
210 MW to 500 MW (see variants)
Technology
Semi-dry
SO2 removal efficiency
80%
Inlet SO2
Up to 1500 mg/Nm3
Absorber material
Alloy lined

Lead time 40-60 weeks · Warranty 24 months performance guarantee · MOQ 5 set

Price on quote

invoiced by BARREL

Request quote

Ash utilisation

Mahabaleshwarjoule · MAH-5C3 series

Fly ash fineness (Blaine)
250 sq m/kg to 400 sq m/kg (see variants)
Source
Bottom ash
Grade
Siliceous Grade 2
Loss on ignition
Below 2%
Moisture
Below 1%

Lead time 1-2 weeks · Warranty Test certificate per lot · MOQ 1 MT

Price for verified buyers

invoiced by BARREL

Request quote

Mahabaleshwarjoule · MAH-288 series

Fly ash fineness (Blaine)
320 sq m/kg to 400 sq m/kg (see variants)
Source
Bottom ash
Grade
Siliceous Grade 1
Loss on ignition
Below 5%
Moisture
Below 5%

Lead time 3-7 days · Warranty Test certificate per lot · MOQ 10 MT

Price for verified buyers

invoiced by BARREL

Request quote

Mahabaleshwarjoule · MAH-568 series

Fly ash fineness (Blaine)
300 sq m/kg to 400 sq m/kg (see variants)
Source
ESP hopper
Grade
Siliceous Grade 2
Loss on ignition
Below 2%
Moisture
Below 1%

Lead time 3-7 days · Warranty Test certificate per lot · MOQ 5 MT

Price on quote

invoiced by BARREL

Request quote

Noise control

Mahabaleshwarjoule · MAH-CA5 series

Insertion loss
15 dB to 40 dB (see variants)
Equipment served
Transformer
Panel construction
Double skin MS
Infill
Rockwool 50 mm
Sheet thickness
2.0 mm

Lead time 6-8 weeks · Warranty 24 months against corrosion · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Mahabaleshwarjoule · MAH-003 series

Insertion loss
25 dB to 40 dB (see variants)
Equipment served
Compressor
Panel construction
GI perforated with rockwool
Infill
Rockwool 100 mm
Sheet thickness
1.6 mm

Lead time 3-4 weeks · Warranty 24 months against corrosion · MOQ 2 nos

Price for verified buyers

invoiced by BARREL

Request quote

Mahabaleshwarjoule · MAH-D08 series

Insertion loss
15 dB to 35 dB (see variants)
Equipment served
Transformer
Panel construction
GI perforated with rockwool
Infill
Rockwool 100 mm
Sheet thickness
2.0 mm

Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 5 nos

Price on quote

invoiced by BARREL

Request quote

SCR / SNCR NOx control

Catalyst module, Eco series

SampleSCR / SNCR NOx control

Mahabaleshwarjoule · MAH-735 series

Flue gas flow
50000 Nm3/h to 250000 Nm3/h (see variants)
Technology
SCR
NOx removal efficiency
85%
Reagent
Aqueous ammonia
Catalyst
Honeycomb V2O5-WO3/TiO2

Lead time 30-44 weeks · Warranty 12 months from commissioning · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

Mahabaleshwarjoule · MAH-9A5 series

Flue gas flow
20000 Nm3/h to 1000000 Nm3/h (see variants)
Technology
SCR
NOx removal efficiency
40%
Reagent
Urea solution 40%
Catalyst
Plate type

Lead time 30-44 weeks · Warranty 12 months from commissioning · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

SNCR urea injection system, Pro 5 series

SampleSCR / SNCR NOx control

Mahabaleshwarjoule · MAH-322 series

Flue gas flow
20000 Nm3/h to 250000 Nm3/h (see variants)
Technology
SNCR
NOx removal efficiency
90%
Reagent
Urea solution 40%
Catalyst
Plate type

Lead time 30-44 weeks · Warranty 12 months from commissioning · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

ESP & bag filters

Mahabaleshwarjoule · MAH-8F3 series

Gas flow rate
10000 Am3/h to 500000 Am3/h (see variants)
Outlet emission
Below 50 mg/Nm3
Inlet temperature
Up to 180 deg C
Filter media
PTFE membrane
Cleaning
Reverse air

Lead time 20-28 weeks · Warranty 24 months on mechanical parts · MOQ 1 set

Price on quote

invoiced by BARREL

Request quote

Mahabaleshwarjoule · MAH-593 series

Gas flow rate
10000 Am3/h to 100000 Am3/h (see variants)
Outlet emission
Below 30 mg/Nm3
Inlet temperature
Up to 250 deg C
Filter media
PPS felt
Cleaning
Reverse air

Lead time 20-28 weeks · Warranty 12 months from commissioning · MOQ 1 set

Price on quote

invoiced by BARREL

Request quote

Mahabaleshwarjoule · MAH-F09 series

Gas flow rate
25000 Am3/h to 500000 Am3/h (see variants)
Outlet emission
Below 30 mg/Nm3
Inlet temperature
Up to 180 deg C
Filter media
PPS felt
Cleaning
Reverse air

Lead time 12-16 weeks · Warranty 12 months from commissioning · MOQ 5 set

Price for verified buyers

invoiced by BARREL

Request quote

CEMS & ambient air monitoring

Stack opacity monitor, Eco series

SampleCEMS & ambient air monitoring

Mahabaleshwarjoule · MAH-CF3 series

Parameters monitored
PM + SO2 + NOx to Full CEMS 8 parameters (see variants)
Measurement method
In-situ
Particulate sensor
Beta attenuation
Gas analyser
Chemiluminescence
Data logging
4-20 mA

Lead time 6-8 weeks · Warranty 12 months from commissioning · MOQ 1 set

Price on quote

invoiced by BARREL

Request quote

Ambient air quality monitoring station, Core series

SampleCEMS & ambient air monitoring

Mahabaleshwarjoule · MAH-6D5 series

Parameters monitored
PM only to Full CEMS 8 parameters (see variants)
Measurement method
Extractive hot-wet
Particulate sensor
Beta attenuation
Gas analyser
UV fluorescence
Data logging
Modbus TCP

Lead time 6-8 weeks · Warranty 24 months on analysers · MOQ 10 set

Price for verified buyers

invoiced by BARREL

Request quote

Online stack gas analyser, Ultra 5 series

SampleCEMS & ambient air monitoring

Mahabaleshwarjoule · MAH-105 series

Parameters monitored
PM only to Full CEMS 8 parameters (see variants)
Measurement method
Extractive hot-wet
Particulate sensor
Opacity
Gas analyser
UV fluorescence
Data logging
4-20 mA

Lead time 6-8 weeks · Warranty 24 months on analysers · MOQ 10 set

Price for verified buyers

invoiced by BARREL

Request quote

BARREL: Bharat Atom Renewable Resources Energy Limited