Merchants / MUNNARSPARKEMISSIO

Munnarspark Emission Systems (Sample)

Munnarspark Emission Systems India Pvt Ltd (Sample)

Verified by BARREL — PAN, GSTIN and company records checked; NDA and non-circumvention signed

Catalogue · 16 listings

Send an RFQ

Prices are shown to verified buyers. Register your company to see them and request quotes. Questions, quotes, orders and invoices all go through BARREL Shop.

Ash utilisation

Munnarspark · MUN-288 series

Fly ash fineness (Blaine)
250 sq m/kg to 400 sq m/kg (see variants)
Source
ESP hopper
Grade
Siliceous Grade 2
Loss on ignition
Below 2%
Moisture
Below 5%

Lead time 1-2 weeks · Warranty Test certificate per lot · MOQ 2 MT

Price for verified buyers

invoiced by BARREL

Request quote

Munnarspark · MUN-461 series

Fly ash fineness (Blaine)
250 sq m/kg to 400 sq m/kg (see variants)
Source
Pond ash
Grade
Siliceous Grade 1
Loss on ignition
Below 5%
Moisture
Below 1%

Lead time 1-2 weeks · Warranty Test certificate per lot · MOQ 2 MT

Price for verified buyers

invoiced by BARREL

Request quote

Fly ash bricks, Ultra 7 series

SampleAsh utilisation

Munnarspark · MUN-397 series

Fly ash fineness (Blaine)
250 sq m/kg to 400 sq m/kg (see variants)
Source
Pond ash
Grade
Siliceous Grade 1
Loss on ignition
Below 2%
Moisture
Below 1%

Lead time 1-2 weeks · Warranty Test certificate per lot · MOQ 1 MT

Price for verified buyers

invoiced by BARREL

Request quote

SCR / SNCR NOx control

Catalyst module, Flex series

SampleSCR / SNCR NOx control

Munnarspark · MUN-731 series

Flue gas flow
250000 Nm3/h to 1000000 Nm3/h (see variants)
Technology
Hybrid
NOx removal efficiency
70%
Reagent
Aqueous ammonia
Catalyst
Plate type

Lead time 30-44 weeks · Warranty 24000 operating hours on catalyst · MOQ 10 set

Price for verified buyers

invoiced by BARREL

Request quote

SNCR urea injection system, Elite series

SampleSCR / SNCR NOx control

Munnarspark · MUN-326 series

Flue gas flow
50000 Nm3/h to 1000000 Nm3/h (see variants)
Technology
SNCR
NOx removal efficiency
90%
Reagent
Ammonia 25%
Catalyst
Plate type

Lead time 16-24 weeks · Warranty 24000 operating hours on catalyst · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

Urea dosing and storage unit, Volt series

SampleSCR / SNCR NOx control

Munnarspark · MUN-9A7 series

Flue gas flow
20000 Nm3/h to 1000000 Nm3/h (see variants)
Technology
Hybrid
NOx removal efficiency
40%
Reagent
Urea solution 40%
Catalyst
Honeycomb V2O5-WO3/TiO2

Lead time 30-44 weeks · Warranty 24000 operating hours on catalyst · MOQ 1 set

Price on quote

invoiced by BARREL

Request quote

Noise control

Munnarspark · MUN-D08 series

Insertion loss
15 dB to 40 dB (see variants)
Equipment served
Transformer
Panel construction
GI perforated with rockwool
Infill
Rockwool 50 mm
Sheet thickness
2.0 mm

Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

Munnarspark · MUN-CA3 series

Insertion loss
15 dB to 35 dB (see variants)
Equipment served
DG set
Panel construction
GI perforated with rockwool
Infill
Rockwool 100 mm
Sheet thickness
2.0 mm

Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 2 nos

Price for verified buyers

invoiced by BARREL

Request quote

Munnarspark · MUN-004 series

Insertion loss
15 dB to 40 dB (see variants)
Equipment served
Compressor
Panel construction
GI perforated with rockwool
Infill
Rockwool 50 mm
Sheet thickness
2.0 mm

Lead time 3-4 weeks · Warranty 24 months against corrosion · MOQ 1 nos

Price for verified buyers

invoiced by BARREL

Request quote

ESP & bag filters

Munnarspark · MUN-458 series

Gas flow rate
25000 Am3/h to 1000000 Am3/h (see variants)
Outlet emission
Below 30 mg/Nm3
Inlet temperature
Up to 250 deg C
Filter media
Polyester
Cleaning
Reverse air

Lead time 20-28 weeks · Warranty 12 months from commissioning · MOQ 2 set

Price for verified buyers

invoiced by BARREL

Request quote

Munnarspark · MUN-2A8 series

Gas flow rate
10000 Am3/h to 50000 Am3/h (see variants)
Outlet emission
Below 30 mg/Nm3
Inlet temperature
Up to 250 deg C
Filter media
PPS felt
Cleaning
Pulse jet

Lead time 12-16 weeks · Warranty 12 months from commissioning · MOQ 2 set

Price for verified buyers

invoiced by BARREL

Request quote

Munnarspark · MUN-8F5 series

Gas flow rate
25000 Am3/h to 250000 Am3/h (see variants)
Outlet emission
Below 50 mg/Nm3
Inlet temperature
Up to 180 deg C
Filter media
PPS felt
Cleaning
Reverse air

Lead time 12-16 weeks · Warranty 24 months on mechanical parts · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

Flue-gas desulphurisation (FGD)

Dry sorbent injection system, Duo 2 series

SampleFlue-gas desulphurisation (FGD)

Munnarspark · MUN-2E1 series

Boiler size
10 MW to 350 MW (see variants)
Technology
Semi-dry
SO2 removal efficiency
95%
Inlet SO2
Up to 2500 mg/Nm3
Absorber material
Alloy lined

Lead time 24-36 weeks · Warranty 24 months performance guarantee · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

Semi-dry FGD with spray dryer, Prime series

SampleFlue-gas desulphurisation (FGD)

Munnarspark · MUN-052 series

Boiler size
25 MW to 500 MW (see variants)
Technology
Wet limestone-gypsum
SO2 removal efficiency
95%
Inlet SO2
Up to 2500 mg/Nm3
Absorber material
Rubber lined carbon steel

Lead time 24-36 weeks · Warranty 12 months from commissioning · MOQ 1 set

Price for verified buyers

invoiced by BARREL

Request quote

CEMS & ambient air monitoring

Continuous emission monitoring system, Volt series

SampleCEMS & ambient air monitoring

Munnarspark · MUN-8B2 series

Parameters monitored
PM + SO2 + NOx to PM + gases + flow (see variants)
Measurement method
Extractive hot-wet
Particulate sensor
Light scattering
Gas analyser
Chemiluminescence
Data logging
Modbus TCP

Lead time 10-14 weeks · Warranty 12 months from commissioning · MOQ 2 set

Price for verified buyers

invoiced by BARREL

Request quote

Ambient air quality monitoring station, Pro series

SampleCEMS & ambient air monitoring

Munnarspark · MUN-6D9 series

Parameters monitored
PM + SO2 + NOx to Full CEMS 8 parameters (see variants)
Measurement method
Extractive hot-wet
Particulate sensor
Beta attenuation
Gas analyser
UV fluorescence
Data logging
Modbus TCP

Lead time 6-8 weeks · Warranty 24 months on analysers · MOQ 10 set

Price on quote

invoiced by BARREL

Request quote

BARREL: Bharat Atom Renewable Resources Energy Limited