Primary & secondary injection kitsEllora6 variants
SamplePrimary & secondary injection kits Ellora · ELL-F45 series
- Output current
- 100 A to 6000 A (see variants)
- Output voltage
- 24 V
- Duty cycle
- Continuous 100 A
- Supply
- 230 V AC
- Meters
- Built-in timer
Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 5 set
Multimeters, clamp meters & insulation testersAkshaymark5 variants
SampleMultimeters, clamp meters & insulation testers Akshaymark · AKS-EE6 series
- Maximum current / voltage range
- 1000 A to 1000 V DC (see variants)
- Measurement
- Resistance
- Display count
- 10000
- Accuracy
- 0.5%
- Safety rating
- CAT IV 600 V
Lead time 3-7 days · Warranty 12 months from supply · MOQ 1 nos
Primary & secondary injection kitsVijaya3 variants
SamplePrimary & secondary injection kits Vijaya · VIJ-3D6 series
- Output current
- 1000 A to 3000 A (see variants)
- Output voltage
- 6 V
- Duty cycle
- Short time 5 min
- Supply
- 415 V AC
- Meters
- Built-in timer
Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 1 set
SFRA, winding resistance & turns-ratio testersPallavasamarth6 variants
SampleSFRA, winding resistance & turns-ratio testers Pallavasamarth · PAL-4F4 series
- Test current / range
- 1 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- SFRA
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 nos
I-V curve tracers & EL testers (solar)Konarkakshay5 variants
SampleI-V curve tracers & EL testers (solar) Konarkakshay · KON-2B3 series
- Max DC voltage / current
- 1000 V 10 A to EL camera 10 MP (see variants)
- Measurement
- I-V curve
- Irradiance sensor
- Reference cell
- Temperature sensor
- PT1000 cell
- Accuracy
- +/-0.5%
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 10 nos
CT/PT & transformer analysersDwarakasamarth4 variants
SampleCT/PT & transformer analysers Dwarakasamarth · DWA-DA7 series
- Test channels / output
- 3-phase 5 kV to Multi-function 60 A (see variants)
- Tests
- Winding resistance
- Class tested
- Class 0.2 to 5P
- Output current
- 0-100 A
- Output voltage
- 0-250 V
Lead time 2-3 weeks · Warranty 24 months with calibration · MOQ 1 nos
Insulation & tan delta testersMalwa6 variants
SampleInsulation & tan delta testers Malwa · MAL-DF5 series
- Maximum test voltage
- 1 kV to 15 kV (see variants)
- Resistance range
- Up to 5 Gohm
- Tests
- IR, PI, DAR, DD
- Display
- Colour TFT
- Power supply
- Rechargeable battery
Lead time 1-2 weeks · Warranty 24 months with calibration · MOQ 5 nos
Insulation & tan delta testersPushpakline4 variants
SampleInsulation & tan delta testers Pushpakline · PUS-DA1 series
- Maximum test voltage
- 5 kV to 15 kV (see variants)
- Resistance range
- Up to 10 Tohm
- Tests
- Tan delta, capacitance
- Display
- Colour TFT
- Power supply
- Rechargeable battery
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 1 nos
Partial discharge & VLF testersKamrupphase6 variants
SamplePartial discharge & VLF testers Kamrupphase · KAM-D42 series
- Test voltage (VLF peak)
- 28 kV to 90 kV (see variants)
- Test frequency
- 0.05 Hz to 0.1 Hz
- Waveform
- Cosine rectangular
- Max load capacitance
- 0.5 microF
- PD sensitivity
- Below 5 pC
Lead time 4-6 weeks · Warranty 24 months with calibration · MOQ 1 set
Circuit-breaker analysersPushpakline4 variants
SampleCircuit-breaker analysers Pushpakline · PUS-6F3 series
- Timing channels
- 3 channels to 12 channels (see variants)
- Time resolution
- 0.05 ms
- Travel transducer
- Both
- DC contact resistance
- 200 A
- Coil current
- Not measured
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 1 nos
Cable fault locatorsMaurya4 variants
SampleCable fault locators Maurya · MAU-893 series
- Surge voltage
- 8 kV to 20 kV (see variants)
- Surge energy
- 300 J
- Methods
- TDR, ARM, Decay
- Cable length range
- Up to 10 km
- Display
- Colour touch
Lead time 8-12 weeks · Warranty 12 months from supply · MOQ 1 set
Cable fault locatorsMalwa4 variants
SampleCable fault locators Malwa · MAL-897 series
- Surge voltage
- 16 kV to 40 kV (see variants)
- Surge energy
- 300 J
- Methods
- Pulse echo, ARM, SIM
- Cable length range
- Up to 20 km
- Display
- Colour touch
Lead time 8-12 weeks · Warranty 12 months from supply · MOQ 1 set
Primary & secondary injection kitsKamrupphase6 variants
SamplePrimary & secondary injection kits Kamrupphase · KAM-3D8 series
- Output current
- 100 A to 6000 A (see variants)
- Output voltage
- 12 V
- Duty cycle
- Short time 5 min
- Supply
- 230 V AC
- Meters
- Built-in timer
Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 1 set
Multimeters, clamp meters & insulation testersMaurya3 variants
SampleMultimeters, clamp meters & insulation testers Maurya · MAU-4D9 series
- Maximum current / voltage range
- 1500 A to 3000 A (flexible) (see variants)
- Measurement
- AC/DC current
- Display count
- 10000
- Accuracy
- 0.5%
- Safety rating
- CAT IV 600 V
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 5 nos
SFRA, winding resistance & turns-ratio testersMagadhlumen6 variants
SampleSFRA, winding resistance & turns-ratio testers Magadhlumen · MAG-365 series
- Test current / range
- 1 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 12 months from supply · MOQ 1 nos
Insulation & tan delta testersKamrupphase4 variants
SampleInsulation & tan delta testers Kamrupphase · KAM-F78 series
- Maximum test voltage
- 2.5 kV to 12 kV (see variants)
- Resistance range
- Up to 10 Tohm
- Tests
- IR, PI, DAR
- Display
- Colour TFT
- Power supply
- Rechargeable battery
Lead time 4-6 weeks · Warranty 24 months with calibration · MOQ 2 nos
Primary & secondary injection kitsKonarkakshay5 variants
SamplePrimary & secondary injection kits Konarkakshay · KON-BB7 series
- Output current
- 500 A to 6000 A (see variants)
- Output voltage
- 6 V
- Duty cycle
- Continuous 100 A
- Supply
- 230 V AC
- Meters
- Digital ammeter 0.5%
Lead time 2-3 weeks · Warranty 12 months from supply · MOQ 1 set
CT/PT & transformer analysersPallavasamarth6 variants
SampleCT/PT & transformer analysers Pallavasamarth · PAL-074 series
- Test channels / output
- Single channel 2 kV to Multi-function 60 A (see variants)
- Tests
- Knee point, excitation
- Class tested
- PS class
- Output current
- 0-30 A
- Output voltage
- 0-250 V
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersBrahmaputra3 variants
SampleSFRA, winding resistance & turns-ratio testers Brahmaputra · BRA-4F5 series
- Test current / range
- 5 A winding resistance to 40 A winding resistance (see variants)
- Instrument
- SFRA
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 1 nos
Thermal camerasKamrupsamarth3 variants
Kamrupsamarth · KAM-FA9 series
- Detector resolution
- 80 x 60 to 240 x 180 (see variants)
- Temperature range
- -20 to 350 deg C
- Thermal sensitivity
- Below 0.1 deg C
- Accuracy
- +/-2 deg C
- Focus
- Autofocus
Lead time 1-2 weeks · Warranty 10 years detector warranty (limited) · MOQ 1 nos
SFRA, winding resistance & turns-ratio testersEllora3 variants
SampleSFRA, winding resistance & turns-ratio testers Ellora · ELL-E21 series
- Test current / range
- 10 A winding resistance to TTR 0.8-10000 (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB
Lead time 6-10 weeks · Warranty 24 months with calibration · MOQ 1 nos
Primary & secondary injection kitsMaurya6 variants
SamplePrimary & secondary injection kits Maurya · MAU-F44 series
- Output current
- 100 A to 6000 A (see variants)
- Output voltage
- 24 V
- Duty cycle
- Short time 5 min
- Supply
- 415 V AC
- Meters
- Built-in timer
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 1 set
Cable fault locatorsMagadhlumen3 variants
SampleCable fault locators Magadhlumen · MAG-1E6 series
- Surge voltage
- 20 kV to 40 kV (see variants)
- Surge energy
- 1000 J
- Methods
- TDR, ARM, Decay
- Cable length range
- Up to 10 km
- Display
- Colour touch
Lead time 8-12 weeks · Warranty 12 months from supply · MOQ 1 set
SFRA, winding resistance & turns-ratio testersShivalik5 variants
SampleSFRA, winding resistance & turns-ratio testers Shivalik · SHI-366 series
- Test current / range
- 5 A winding resistance to SFRA 20 Hz-2 MHz (see variants)
- Instrument
- Winding resistance
- Accuracy
- 0.1%
- Frequency range
- 20 Hz to 2 MHz
- Dynamic range
- Over 100 dB