Bushings, OLTC & transformer accessoriesMadurai5 variants
SampleBushings, OLTC & transformer accessories Madurai · MAD-AD4 series
- Voltage class
- 11 kV to 220 kV (see variants)
- Component
- OTI/WTI
- Current rating
- 2000 A
- Insulation type
- RIP
- Creepage
- 25 mm/kV
Lead time 12-20 weeks · Warranty 18 months · MOQ 2 nos
Shunt & series reactorsCoromandel5 variants
SampleShunt & series reactors Coromandel · COR-2C8 series
- Rating
- 5 MVAr to 80 MVAr (see variants)
- System voltage
- 33 kV
- Type
- Neutral
- Construction
- Air-core dry
- Phases
- Three
Lead time 40-50 weeks · Warranty 24 months from commissioning · MOQ 10 nos
Shunt & series reactorsHampiohm5 variants
SampleShunt & series reactors Hampiohm · HAM-2C5 series
- Rating
- 25 MVAr to 200 MVAr (see variants)
- System voltage
- 220 kV
- Type
- Shunt
- Construction
- Oil-immersed gapped core
- Phases
- Single
Lead time 40-50 weeks · Warranty 36 months from supply · MOQ 10 nos
Transformer monitoring (online DGA, bushing monitors)Awadhakshay4 variants
SampleTransformer monitoring (online DGA, bushing monitors) Awadhakshay · AWA-876 series
- Gases monitored
- Single gas (H2) to 9 gases (see variants)
- Gases measured
- H2, CO, C2H2
- Technology
- Gas chromatography
- Measurement interval
- 24 hours
- Accuracy
- +/- 10%
Lead time 8-10 weeks · Warranty 36 months with AMC · MOQ 2 nos
Instrument transformers (CT, PT, CVT)Bundel6 variants
SampleInstrument transformers (CT, PT, CVT) Bundel · BUN-795 series
- System voltage
- 11 kV to 400 kV (see variants)
- Type
- Current transformer
- Ratio
- 132 kV/110 V
- Accuracy class
- 0.5
- Burden
- 30 VA
Lead time 10-14 weeks · Warranty 18 months · MOQ 10 nos
Bushings, OLTC & transformer accessoriesKaverianant6 variants
SampleBushings, OLTC & transformer accessories Kaverianant · KAV-287 series
- Voltage class
- 11 kV to 400 kV (see variants)
- Component
- PRV
- Current rating
- 3150 A
- Insulation type
- OIP
- Creepage
- 25 mm/kV
Lead time 12-20 weeks · Warranty 18 months · MOQ 1 nos
Mobile substationsMadurai5 variants
Madurai · MAD-031 series
- Transformer rating
- 10 MVA to 63 MVA (see variants)
- Primary voltage
- 66 kV
- Secondary voltage
- 33 kV
- Chassis
- Skid
- Primary switchgear
- AIS disconnector and breaker
Lead time 30-40 weeks · Warranty 36 months · MOQ 1 nos
Instrument transformers (CT, PT, CVT)Bundel5 variants
SampleInstrument transformers (CT, PT, CVT) Bundel · BUN-0F1 series
- System voltage
- 33 kV to 400 kV (see variants)
- Type
- Combined CT-PT
- Ratio
- 400-800/1 A
- Accuracy class
- PS
- Burden
- 50 VA
Lead time 4-6 weeks · Warranty 18 months · MOQ 10 nos
Distribution transformersNilgirispark5 variants
SampleDistribution transformers Nilgirispark · NIL-C13 series
- Rating
- 25 kVA to 315 kVA (see variants)
- Voltage ratio
- 11/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Level 1
Lead time 2-3 weeks · Warranty 18 months from supply · MOQ 1 nos
Furnace & rectifier transformersMauryajal4 variants
SampleFurnace & rectifier transformers Mauryajal · MAU-917 series
- Rating
- 2 MVA to 20 MVA (see variants)
- Primary voltage
- 66 kV
- Secondary voltage
- Up to 1000 V
- Application
- Rectifier
- Cooling
- OFWF
Lead time 28-36 weeks · Warranty 24 months · MOQ 1 nos
Bushings, OLTC & transformer accessoriesHampiohm5 variants
SampleBushings, OLTC & transformer accessories Hampiohm · HAM-431 series
- Voltage class
- 11 kV to 220 kV (see variants)
- Component
- OTI/WTI
- Current rating
- 2000 A
- Insulation type
- OIP
- Creepage
- 25 mm/kV
Lead time 12-20 weeks · Warranty 18 months · MOQ 10 nos
Power transformersNarmadapushpak6 variants
Narmadapushpak · NAR-274 series
- Rating
- 31.5 MVA to 500 MVA (see variants)
- Voltage ratio
- 220/132 kV
- Cooling
- ONAN/ONAF/OFAF
- Vector group
- Dyn11
- Tap changer
- OLTC +/- 10% in 16 steps
Lead time 16-24 weeks · Warranty 36 months from supply · MOQ 1 nos
Compact secondary substationsJalline3 variants
SampleCompact secondary substations Jalline · JAL-117 series
- Transformer rating
- 250 kVA to 630 kVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- 0.69 kV
- HV equipment
- Ring main unit
- Transformer type
- Oil-immersed
Lead time 6-8 weeks · Warranty 18 months · MOQ 10 nos
Distribution transformersKonark3 variants
SampleDistribution transformers Konark · KON-487 series
- Rating
- 16 kVA to 63 kVA (see variants)
- Voltage ratio
- 33/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Amorphous
Lead time 2-3 weeks · Warranty 12 months from commissioning · MOQ 1 nos
Distribution transformersCoorgswarna4 variants
SampleDistribution transformers Coorgswarna · COO-5B6 series
- Rating
- 315 kVA to 2500 kVA (see variants)
- Voltage ratio
- 33/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Level 2
Lead time 2-3 weeks · Warranty 18 months from supply · MOQ 1 nos
Instrument transformers (CT, PT, CVT)Taxilaurja5 variants
SampleInstrument transformers (CT, PT, CVT) Taxilaurja · TAX-0F2 series
- System voltage
- 33 kV to 400 kV (see variants)
- Type
- CVT
- Ratio
- 132 kV/110 V
- Accuracy class
- 1.0
- Burden
- 30 VA
Lead time 4-6 weeks · Warranty 18 months · MOQ 5 nos
Instrument transformers (CT, PT, CVT)Jalline4 variants
SampleInstrument transformers (CT, PT, CVT) Jalline · JAL-985 series
- System voltage
- 66 kV to 400 kV (see variants)
- Type
- CVT
- Ratio
- 132 kV/110 V
- Accuracy class
- 5P20
- Burden
- 30 VA
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 2 nos
Inverter duty transformersCoorgswarna4 variants
SampleInverter duty transformers Coorgswarna · COO-7B8 series
- Rating
- 3.15 MVA to 6.3 MVA (see variants)
- Voltage ratio
- 22/0.69 kV
- Windings
- Two
- Vector group
- Dy11y11
- Cooling
- ONAN
Lead time 6-8 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Bushings, OLTC & transformer accessoriesKakatiya3 variants
SampleBushings, OLTC & transformer accessories Kakatiya · KAK-174 series
- Voltage class
- 132 kV to 400 kV (see variants)
- Component
- PRV
- Current rating
- 3150 A
- Insulation type
- RIS
- Creepage
- 25 mm/kV
Lead time 3-6 weeks · Warranty 24 months · MOQ 1 nos
Mobile substationsAwadhakshay6 variants
Awadhakshay · AWA-346 series
- Transformer rating
- 5 MVA to 63 MVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- 33 kV
- Chassis
- Container
- Primary switchgear
- AIS disconnector and breaker
Lead time 16-24 weeks · Warranty 24 months · MOQ 1 nos
Earthing & auxiliary transformersCoromandel3 variants
SampleEarthing & auxiliary transformers Coromandel · COR-FC5 series
- Rating
- 50 kVA to 315 kVA (see variants)
- Type
- Auxiliary (Dyn11)
- Primary voltage
- 11 kV
- Secondary voltage
- 3.3 kV
- Short-time rating
- 30 s
Lead time 8-10 weeks · Warranty 18 months · MOQ 1 nos
Compact secondary substationsKonark4 variants
SampleCompact secondary substations Konark · KON-9A3 series
- Transformer rating
- 100 kVA to 630 kVA (see variants)
- Primary voltage
- 22 kV
- Secondary voltage
- 0.433 kV
- HV equipment
- VCB panel
- Transformer type
- Cast resin dry
Lead time 10-14 weeks · Warranty 18 months · MOQ 5 nos
Earthing & auxiliary transformersSabarmati4 variants
SampleEarthing & auxiliary transformers Sabarmati · SAB-C07 series
- Rating
- 315 kVA to 1600 kVA (see variants)
- Type
- Earthing (zig-zag)
- Primary voltage
- 33 kV
- Secondary voltage
- 3.3 kV
- Short-time rating
- 10 s
Lead time 8-10 weeks · Warranty 18 months · MOQ 2 nos
Earthing & auxiliary transformersAmaravati5 variants
SampleEarthing & auxiliary transformers Amaravati · AMA-2C9 series
- Rating
- 100 kVA to 1600 kVA (see variants)
- Type
- Earthing (zig-zag)
- Primary voltage
- 33 kV
- Secondary voltage
- 3.3 kV
- Short-time rating
- 10 s
Lead time 3-5 weeks · Warranty 18 months · MOQ 2 nos