Instrument transformers (CT, PT, CVT)Coromandel5 variants
SampleInstrument transformers (CT, PT, CVT) Coromandel · COR-BD3 series
- System voltage
- 11 kV to 220 kV (see variants)
- Type
- Voltage transformer
- Ratio
- 100-200/1 A
- Accuracy class
- 1.0
- Burden
- 15 VA
Lead time 10-14 weeks · Warranty 18 months · MOQ 5 nos
Compact secondary substationsNarmadapushpak4 variants
SampleCompact secondary substations Narmadapushpak · NAR-571 series
- Transformer rating
- 250 kVA to 1000 kVA (see variants)
- Primary voltage
- 11 kV
- Secondary voltage
- 0.69 kV
- HV equipment
- VCB panel
- Transformer type
- Oil-immersed
Lead time 6-8 weeks · Warranty 18 months · MOQ 1 nos
Shunt & series reactorsTejmark4 variants
SampleShunt & series reactors Tejmark · TEJ-759 series
- Rating
- 25 MVAr to 125 MVAr (see variants)
- System voltage
- 400 kV
- Type
- Shunt
- Construction
- Air-core dry
- Phases
- Single
Lead time 20-28 weeks · Warranty 24 months from commissioning · MOQ 10 nos
Distribution transformersHampiohm5 variants
SampleDistribution transformers Hampiohm · HAM-5B1 series
- Rating
- 200 kVA to 2500 kVA (see variants)
- Voltage ratio
- 33/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Level 2
Lead time 4-6 weeks · Warranty 18 months from supply · MOQ 1 nos
Power transformersBrahmaputra5 variants
Brahmaputra · BRA-F73 series
- Rating
- 20 MVA to 160 MVA (see variants)
- Voltage ratio
- 220/132 kV
- Cooling
- ONAN/ONAF
- Vector group
- YNyn0 d11
- Tap changer
- OLTC +/- 10% in 16 steps
Lead time 16-24 weeks · Warranty 36 months from supply · MOQ 5 nos
Inverter duty transformersHampiohm4 variants
SampleInverter duty transformers Hampiohm · HAM-208 series
- Rating
- 3.15 MVA to 6.3 MVA (see variants)
- Voltage ratio
- 22/0.69 kV
- Windings
- Two
- Vector group
- Dy11y11
- Cooling
- ONAN
Lead time 6-8 weeks · Warranty 24 months from commissioning · MOQ 10 nos
Mobile substationsMadurai6 variants
Madurai · MAD-342 series
- Transformer rating
- 5 MVA to 63 MVA (see variants)
- Primary voltage
- 66 kV
- Secondary voltage
- 11 kV
- Chassis
- Skid
- Primary switchgear
- AIS disconnector and breaker
Lead time 30-40 weeks · Warranty 24 months · MOQ 5 nos
Distribution transformersKaverianant3 variants
SampleDistribution transformers Kaverianant · KAV-F86 series
- Rating
- 200 kVA to 500 kVA (see variants)
- Voltage ratio
- 33/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Amorphous
Lead time 2-3 weeks · Warranty 12 months from commissioning · MOQ 1 nos
Mobile substationsNilgirispark3 variants
Nilgirispark · NIL-343 series
- Transformer rating
- 10 MVA to 31.5 MVA (see variants)
- Primary voltage
- 66 kV
- Secondary voltage
- 33 kV
- Chassis
- Low-bed trailer
- Primary switchgear
- AIS disconnector and breaker
Lead time 16-24 weeks · Warranty 36 months · MOQ 5 nos
Power transformersKakatiya6 variants
Kakatiya · KAK-F79 series
- Rating
- 31.5 MVA to 500 MVA (see variants)
- Voltage ratio
- 220/132 kV
- Cooling
- ONAN/ONAF
- Vector group
- YNyn0 d11
- Tap changer
- OLTC 1.25% steps
Lead time 16-24 weeks · Warranty 24 months from commissioning · MOQ 5 nos
Shunt & series reactorsNarmadapushpak4 variants
SampleShunt & series reactors Narmadapushpak · NAR-5D4 series
- Rating
- 5 MVAr to 50 MVAr (see variants)
- System voltage
- 400 kV
- Type
- Neutral
- Construction
- Air-core dry
- Phases
- Single
Lead time 40-50 weeks · Warranty 36 months from supply · MOQ 10 nos
Distribution transformersBrahmaputra4 variants
SampleDistribution transformers Brahmaputra · BRA-C11 series
- Rating
- 200 kVA to 1000 kVA (see variants)
- Voltage ratio
- 11/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Level 2
Lead time 4-6 weeks · Warranty 18 months from supply · MOQ 1 nos
Distribution transformersEllora5 variants
SampleDistribution transformers Ellora · ELL-F81 series
- Rating
- 25 kVA to 315 kVA (see variants)
- Voltage ratio
- 11/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Amorphous
Lead time 2-3 weeks · Warranty 12 months from commissioning · MOQ 1 nos
Instrument transformers (CT, PT, CVT)Sabarmati3 variants
SampleInstrument transformers (CT, PT, CVT) Sabarmati · SAB-C47 series
- System voltage
- 132 kV to 400 kV (see variants)
- Type
- CVT
- Ratio
- 1200-2400/1 A
- Accuracy class
- 0.5
- Burden
- 15 VA
Lead time 10-14 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Dry-type transformersHampiohm3 variants
SampleDry-type transformers Hampiohm · HAM-ED3 series
- Rating
- 250 kVA to 1000 kVA (see variants)
- Voltage ratio
- 11/0.433 kV
- Technology
- VPI
- Insulation class
- Class F
- Cooling
- AN/AF
Lead time 4-6 weeks · Warranty 36 months · MOQ 1 nos
Bushings, OLTC & transformer accessoriesBundel6 variants
SampleBushings, OLTC & transformer accessories Bundel · BUN-281 series
- Voltage class
- 11 kV to 400 kV (see variants)
- Component
- OTI/WTI
- Current rating
- 1250 A
- Insulation type
- RIS
- Creepage
- 31 mm/kV
Lead time 12-20 weeks · Warranty 24 months · MOQ 10 nos
Earthing & auxiliary transformersMadurai4 variants
SampleEarthing & auxiliary transformers Madurai · MAD-C06 series
- Rating
- 315 kVA to 1600 kVA (see variants)
- Type
- Earthing (zig-zag)
- Primary voltage
- 132 kV
- Secondary voltage
- 3.3 kV
- Short-time rating
- 10 s
Lead time 8-10 weeks · Warranty 24 months · MOQ 2 nos
Compact secondary substationsNilgirispark5 variants
SampleCompact secondary substations Nilgirispark · NIL-119 series
- Transformer rating
- 250 kVA to 1600 kVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- 0.433 kV
- HV equipment
- Fuse switch
- Transformer type
- Cast resin dry
Lead time 10-14 weeks · Warranty 24 months · MOQ 1 nos
Furnace & rectifier transformersKaverianant6 variants
SampleFurnace & rectifier transformers Kaverianant · KAV-646 series
- Rating
- 2 MVA to 60 MVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- Up to 1000 V
- Application
- LRF
- Cooling
- OFWF
Lead time 16-20 weeks · Warranty 36 months from supply · MOQ 10 nos
Instrument transformers (CT, PT, CVT)Tejmark6 variants
SampleInstrument transformers (CT, PT, CVT) Tejmark · TEJ-984 series
- System voltage
- 11 kV to 400 kV (see variants)
- Type
- Combined CT-PT
- Ratio
- 100-200/1 A
- Accuracy class
- PS
- Burden
- 15 VA
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Power transformersSamarthtek3 variants
Samarthtek · SAM-1D5 series
- Rating
- 50 MVA to 160 MVA (see variants)
- Voltage ratio
- 132/33 kV
- Cooling
- ONAN/ONAF/OFAF
- Vector group
- Dyn11
- Tap changer
- OLTC 1.25% steps
Lead time 30-40 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Earthing & auxiliary transformersTaxilaurja6 variants
SampleEarthing & auxiliary transformers Taxilaurja · TAX-C03 series
- Rating
- 100 kVA to 3150 kVA (see variants)
- Type
- Station service
- Primary voltage
- 33 kV
- Secondary voltage
- 0.433 kV
- Short-time rating
- 10 s
Lead time 8-10 weeks · Warranty 18 months · MOQ 1 nos
Power transformersAjantajyoti4 variants
Ajantajyoti · AJA-F74 series
- Rating
- 20 MVA to 100 MVA (see variants)
- Voltage ratio
- 220/132 kV
- Cooling
- ONAN/ONAF
- Vector group
- YNyn0 d11
- Tap changer
- OLTC +/- 10% in 16 steps
Lead time 30-40 weeks · Warranty 36 months from supply · MOQ 10 nos
Inverter duty transformersBrahmaputra4 variants
SampleInverter duty transformers Brahmaputra · BRA-F57 series
- Rating
- 3.15 MVA to 6.3 MVA (see variants)
- Voltage ratio
- 33/0.69/0.69 kV
- Windings
- Two
- Vector group
- Dyn11
- Cooling
- ONAN
Lead time 10-14 weeks · Warranty 24 months from commissioning · MOQ 1 nos