Ring main units (RMU)Lohacore4 variants
SampleRing main units (RMU) Lohacore · LOH-161 series
- Configuration
- 2-way (LBS+LBS) to 4-way (2LBS+LBS+VCB) (see variants)
- Rated voltage
- 12 kV
- Rated current - ring
- 400 A
- Transformer feeder
- 200 A fuse-switch
- Short-circuit rating
- 16 kA/3 s
Lead time 4-6 weeks · Warranty 24 months from supply · MOQ 1 nos
ACB, MCCB & MCBMysoreohm3 variants
Mysoreohm · MYS-C57 series
- Rating
- 630 A to 2500 A (see variants)
- Breaker type
- ACB
- Poles
- 1P
- Rated voltage
- 240 V AC
- Breaking capacity (Icu)
- 25 kA
Lead time 3-5 weeks · Warranty 24 months from supply · MOQ 10 nos
ACB, MCCB & MCBSaurashtra5 variants
Saurashtra · SAU-271 series
- Rating
- 100 A to 2500 A (see variants)
- Breaker type
- MCB
- Poles
- 4P
- Rated voltage
- 690 V AC
- Breaking capacity (Icu)
- 50 kA
Lead time 3-5 weeks · Warranty 24 months from supply · MOQ 1 nos
Ring main units (RMU)Saurashtra6 variants
SampleRing main units (RMU) Saurashtra · SAU-991 series
- Configuration
- 2-way (LBS+LBS) to 5-way (3LBS+2VCB) (see variants)
- Rated voltage
- 24 kV
- Rated current - ring
- 400 A
- Transformer feeder
- 630 A VCB
- Short-circuit rating
- 25 kA/3 s
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 5 nos
PCC, MCC, ACDB, DCDBNilgirisudarshan6 variants
SamplePCC, MCC, ACDB, DCDB Nilgirisudarshan · NIL-109 series
- Rating
- 400 A to 4000 A (see variants)
- Panel type
- DCDB
- System voltage
- 110 V DC
- Short-circuit rating
- 25 kA/1 s
- Form of separation
- Form 2b
Lead time 3-4 weeks · Warranty 18 months from supply · MOQ 1 nos
MV metal-clad switchboards (11–33 kV)Kamrup3 variants
SampleMV metal-clad switchboards (11–33 kV) Kamrup · KAM-6E7 series
- Rating
- 22 kV 1250 A to 33 kV 2000 A (see variants)
- Insulation
- Solid insulated
- Short-circuit rating
- 25 kA/3 s
- Panel function
- Metering PT
- Busbar
- Double busbar
Lead time 12-16 weeks · Warranty 24 months from supply · MOQ 1 nos
PCC, MCC, ACDB, DCDBKamrup4 variants
SamplePCC, MCC, ACDB, DCDB Kamrup · KAM-B11 series
- Rating
- 400 A to 1600 A (see variants)
- Panel type
- DCDB
- System voltage
- 415 V AC
- Short-circuit rating
- 25 kA/1 s
- Form of separation
- Form 3b
Lead time 6-8 weeks · Warranty 18 months from supply · MOQ 2 nos
Contactors, overload relays & motor startersWayanadvajra4 variants
SampleContactors, overload relays & motor starters Wayanadvajra · WAY-566 series
- Rating
- 65 A to 265 A (see variants)
- Device type
- Star-delta starter
- Coil voltage
- 415 V AC
- Utilisation category
- AC-3
- Motor rating at 415 V
- 30 kW
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
VCB panelsSaurashtra3 variants
Saurashtra · SAU-388 series
- Rating
- 22 kV 630 A to 33 kV 1250 A (see variants)
- Short-circuit rating
- 40 kA/3 s
- Construction
- Metal-enclosed fixed
- Breaker operating duty
- O-0.3 s-CO-3 min-CO
- Control voltage
- 110 V DC
Lead time 4-6 weeks · Warranty 18 months from supply · MOQ 5 nos
VCB panelsLohacore5 variants
Lohacore · LOH-383 series
- Rating
- 11 kV 630 A to 33 kV 630 A (see variants)
- Short-circuit rating
- 25 kA/3 s
- Construction
- Metal-enclosed fixed
- Breaker operating duty
- O-0.3 s-CO-3 min-CO
- Control voltage
- 110 V DC
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 10 nos
PCC, MCC, ACDB, DCDBSamarthmax6 variants
SamplePCC, MCC, ACDB, DCDB Samarthmax · SAM-6C5 series
- Rating
- 250 A to 2500 A (see variants)
- Panel type
- ACDB
- System voltage
- 110 V DC
- Short-circuit rating
- 36 kA/1 s
- Form of separation
- Form 4b
Lead time 3-4 weeks · Warranty 18 months from supply · MOQ 1 nos
Changeover switches & ATS panelsMysoreohm4 variants
SampleChangeover switches & ATS panels Mysoreohm · MYS-B45 series
- Rating
- 630 A to 2500 A (see variants)
- Type
- Manual changeover
- Poles
- 4P
- Rated voltage
- 415 V AC
- Transfer device
- Interlocked ACB
Lead time 1-2 weeks · Warranty 18 months from supply · MOQ 1 nos
Changeover switches & ATS panelsLonavala3 variants
SampleChangeover switches & ATS panels Lonavala · LON-2B2 series
- Rating
- 250 A to 630 A (see variants)
- Type
- Motorised changeover
- Poles
- 3P
- Rated voltage
- 415 V AC
- Transfer device
- Interlocked MCCB
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 1 nos
Bus ductsMarwar4 variants
Marwar · MAR-454 series
- Rating
- 630 A to 2500 A (see variants)
- Conductor
- Aluminium
- Rated voltage
- 1000 V
- Construction
- Sandwich type
- Short-circuit withstand
- 85 kA/1 s
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 1 m
MV metal-clad switchboards (11–33 kV)Nilgirisudarshan4 variants
SampleMV metal-clad switchboards (11–33 kV) Nilgirisudarshan · NIL-362 series
- Rating
- 11 kV 630 A to 22 kV 1250 A (see variants)
- Insulation
- Air-insulated
- Short-circuit rating
- 40 kA/3 s
- Panel function
- Incomer
- Busbar
- Double busbar
Lead time 8-10 weeks · Warranty 24 months from supply · MOQ 10 nos
Changeover switches & ATS panelsHampitej4 variants
SampleChangeover switches & ATS panels Hampitej · HAM-BE6 series
- Rating
- 630 A to 2500 A (see variants)
- Type
- Motorised changeover
- Poles
- 4P
- Rated voltage
- 415 V AC
- Transfer device
- Contactor pair
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 5 nos
Changeover switches & ATS panelsSamarthmax3 variants
SampleChangeover switches & ATS panels Samarthmax · SAM-258 series
- Rating
- 250 A to 630 A (see variants)
- Type
- Motorised changeover
- Poles
- 4P
- Rated voltage
- 415 V AC
- Transfer device
- Interlocked MCCB
Lead time 1-2 weeks · Warranty 12 months from commissioning · MOQ 1 nos
ACB, MCCB & MCBKamrup3 variants
Kamrup · KAM-C57 series
- Rating
- 630 A to 2500 A (see variants)
- Breaker type
- MCB
- Poles
- 1P
- Rated voltage
- 415 V AC
- Breaking capacity (Icu)
- 85 kA
Lead time 1-2 weeks · Warranty 24 months from supply · MOQ 10 nos
MV metal-clad switchboards (11–33 kV)Saurashtra5 variants
SampleMV metal-clad switchboards (11–33 kV) Saurashtra · SAU-5C5 series
- Rating
- 11 kV 630 A to 33 kV 1250 A (see variants)
- Insulation
- Air-insulated
- Short-circuit rating
- 31.5 kA/3 s
- Panel function
- Incomer
- Busbar
- Single busbar
Lead time 12-16 weeks · Warranty 18 months from commissioning · MOQ 1 nos
Changeover switches & ATS panelsNilgirisudarshan4 variants
SampleChangeover switches & ATS panels Nilgirisudarshan · NIL-2B3 series
- Rating
- 125 A to 630 A (see variants)
- Type
- Manual changeover
- Poles
- 3P
- Rated voltage
- 415 V AC
- Transfer device
- Interlocked MCCB
Lead time 4-6 weeks · Warranty 18 months from supply · MOQ 10 nos
Contactors, overload relays & motor startersVindhya3 variants
SampleContactors, overload relays & motor starters Vindhya · VIN-5B6 series
- Rating
- 65 A to 185 A (see variants)
- Device type
- Contactor
- Coil voltage
- 110 V AC
- Utilisation category
- AC-4
- Motor rating at 415 V
- 200 kW
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
Bus ductsDwarakaurja5 variants
Dwarakaurja · DWA-332 series
- Rating
- 1000 A to 4000 A (see variants)
- Conductor
- Copper
- Rated voltage
- 690 V
- Construction
- Air-insulated
- Short-circuit withstand
- 85 kA/1 s
Lead time 8-10 weeks · Warranty 12 months from commissioning · MOQ 10 m
Changeover switches & ATS panelsMysoreohm6 variants
SampleChangeover switches & ATS panels Mysoreohm · MYS-2B8 series
- Rating
- 250 A to 2500 A (see variants)
- Type
- Motorised changeover
- Poles
- 3P
- Rated voltage
- 415 V AC
- Transfer device
- Switch-disconnector
Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 1 nos
Changeover switches & ATS panelsKamrup5 variants
SampleChangeover switches & ATS panels Kamrup · KAM-BE4 series
- Rating
- 400 A to 2500 A (see variants)
- Type
- Motorised changeover
- Poles
- 3P
- Rated voltage
- 415 V AC
- Transfer device
- Interlocked ACB
Lead time 1-2 weeks · Warranty 18 months from supply · MOQ 5 nos