VCB panelsHampitej6 variants
Hampitej · HAM-B75 series
- Rating
- 11 kV 630 A to 33 kV 1250 A (see variants)
- Short-circuit rating
- 25 kA/3 s
- Construction
- Metal-clad withdrawable
- Breaker operating duty
- O-0.3 s-CO-3 min-CO
- Control voltage
- 220 V DC
Lead time 8-10 weeks · Warranty 12 months from commissioning · MOQ 10 nos
Contactors, overload relays & motor startersLonavala4 variants
SampleContactors, overload relays & motor starters Lonavala · LON-566 series
- Rating
- 9 A to 65 A (see variants)
- Device type
- Contactor
- Coil voltage
- 24 V AC
- Utilisation category
- AC-4
- Motor rating at 415 V
- 30 kW
Lead time 1-2 weeks · Warranty 18 months from supply · MOQ 1 nos
PCC, MCC, ACDB, DCDBKrishnaprithvi4 variants
SamplePCC, MCC, ACDB, DCDB Krishnaprithvi · KRI-A45 series
- Rating
- 100 A to 630 A (see variants)
- Panel type
- MCC
- System voltage
- 690 V AC
- Short-circuit rating
- 25 kA/1 s
- Form of separation
- Form 3b
Lead time 3-4 weeks · Warranty 12 months from commissioning · MOQ 10 nos
PCC, MCC, ACDB, DCDBSaurashtra4 variants
SamplePCC, MCC, ACDB, DCDB Saurashtra · SAU-B19 series
- Rating
- 250 A to 1000 A (see variants)
- Panel type
- PCC
- System voltage
- 220 V DC
- Short-circuit rating
- 50 kA/1 s
- Form of separation
- Form 2b
Lead time 3-4 weeks · Warranty 12 months from commissioning · MOQ 5 nos
PCC, MCC, ACDB, DCDBSaurashtra5 variants
SamplePCC, MCC, ACDB, DCDB Saurashtra · SAU-709 series
- Rating
- 630 A to 4000 A (see variants)
- Panel type
- MCC
- System voltage
- 415 V AC
- Short-circuit rating
- 36 kA/1 s
- Form of separation
- Form 3b
Lead time 6-8 weeks · Warranty 12 months from commissioning · MOQ 2 nos
VCB panelsVidarbhasudarshan4 variants
Vidarbhasudarshan · VID-387 series
- Rating
- 11 kV 630 A to 22 kV 630 A (see variants)
- Short-circuit rating
- 31.5 kA/3 s
- Construction
- Metal-clad withdrawable
- Breaker operating duty
- O-0.3 s-CO-3 min-CO
- Control voltage
- 110 V DC
Lead time 8-10 weeks · Warranty 12 months from commissioning · MOQ 1 nos
MV metal-clad switchboards (11–33 kV)Vindhya5 variants
SampleMV metal-clad switchboards (11–33 kV) Vindhya · VIN-935 series
- Rating
- 11 kV 2500 A to 33 kV 2500 A (see variants)
- Insulation
- Solid insulated
- Short-circuit rating
- 40 kA/3 s
- Panel function
- Metering PT
- Busbar
- Single busbar
Lead time 8-10 weeks · Warranty 24 months from supply · MOQ 1 nos
Bus ductsTamracore3 variants
Tamracore · TAM-454 series
- Rating
- 1600 A to 3200 A (see variants)
- Conductor
- Tinned copper
- Rated voltage
- 690 V
- Construction
- Sandwich type
- Short-circuit withstand
- 65 kA/1 s
Lead time 8-10 weeks · Warranty 24 months from supply · MOQ 1 m
Contactors, overload relays & motor startersMarwar5 variants
SampleContactors, overload relays & motor starters Marwar · MAR-564 series
- Rating
- 32 A to 265 A (see variants)
- Device type
- DOL starter
- Coil voltage
- 24 V DC
- Utilisation category
- AC-3
- Motor rating at 415 V
- 15 kW
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 1 nos
Changeover switches & ATS panelsHampitej6 variants
SampleChangeover switches & ATS panels Hampitej · HAM-2B2 series
- Rating
- 125 A to 1600 A (see variants)
- Type
- Manual changeover
- Poles
- 3P
- Rated voltage
- 415 V AC
- Transfer device
- Switch-disconnector
Lead time 1-2 weeks · Warranty 18 months from supply · MOQ 5 nos
Contactors, overload relays & motor startersLonavala6 variants
SampleContactors, overload relays & motor starters Lonavala · LON-563 series
- Rating
- 18 A to 265 A (see variants)
- Device type
- Star-delta starter
- Coil voltage
- 24 V DC
- Utilisation category
- AC-4
- Motor rating at 415 V
- 90 kW
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
Contactors, overload relays & motor startersCoromandelampere5 variants
SampleContactors, overload relays & motor starters Coromandelampere · COR-039 series
- Rating
- 32 A to 265 A (see variants)
- Device type
- Soft starter
- Coil voltage
- 110 V AC
- Utilisation category
- AC-1
- Motor rating at 415 V
- 15 kW
Lead time 1-2 weeks · Warranty 12 months from supply · MOQ 10 nos
PCC, MCC, ACDB, DCDBVidarbhasudarshan3 variants
SamplePCC, MCC, ACDB, DCDB Vidarbhasudarshan · VID-108 series
- Rating
- 400 A to 1000 A (see variants)
- Panel type
- ACDB
- System voltage
- 220 V DC
- Short-circuit rating
- 25 kA/1 s
- Form of separation
- Form 3b
Lead time 3-4 weeks · Warranty 12 months from commissioning · MOQ 2 nos
MV metal-clad switchboards (11–33 kV)Saurashtra4 variants
SampleMV metal-clad switchboards (11–33 kV) Saurashtra · SAU-6E2 series
- Rating
- 11 kV 630 A to 22 kV 1250 A (see variants)
- Insulation
- Air-insulated
- Short-circuit rating
- 40 kA/3 s
- Panel function
- Bus coupler
- Busbar
- Double busbar
Lead time 12-16 weeks · Warranty 18 months from commissioning · MOQ 1 nos
ACB, MCCB & MCBSamarthmax5 variants
Samarthmax · SAM-C54 series
- Rating
- 16 A to 630 A (see variants)
- Breaker type
- MCCB
- Poles
- 3P
- Rated voltage
- 415 V AC
- Breaking capacity (Icu)
- 85 kA
Lead time 3-5 weeks · Warranty 12 months from supply · MOQ 2 nos