SCADA, RTU & plant controllersKonkan6 variants
SampleSCADA, RTU & plant controllers Konkan · KON-262 series
- I/O capacity
- 16 DI / 8 DO to 512 I/O modular (see variants)
- Protocols
- IEC 60870-5-101/104
- CPU
- Industrial x86 dual-core
- Power supply
- 24 VDC
- Operating temperature
- -25 to 70 °C
Lead time 8-10 weeks · Warranty 24 months from commissioning · MOQ 5 nos
SCADA, RTU & plant controllersPennar4 variants
SampleSCADA, RTU & plant controllers Pennar · PEN-3C8 series
- I/O capacity
- 16 DI / 8 DO to 128 I/O modular (see variants)
- Protocols
- IEC 60870-5-101/104
- CPU
- Industrial x86 dual-core
- Power supply
- 48 VDC
- Operating temperature
- -10 to 60 °C
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 2 nos
SCADA, RTU & plant controllersPennaranant4 variants
SampleSCADA, RTU & plant controllers Pennaranant · PEN-022 series
- I/O capacity
- 64 DI / 32 DO / 16 AI to 512 I/O modular (see variants)
- Protocols
- Modbus RTU/TCP
- CPU
- ARM Cortex-A9
- Power supply
- 110-220 VDC/VAC
- Operating temperature
- -10 to 60 °C
Lead time 4-6 weeks · Warranty 36 months from supply · MOQ 1 nos
SCADA, RTU & plant controllersHoysala5 variants
SampleSCADA, RTU & plant controllers Hoysala · HOY-3C6 series
- I/O capacity
- 16 DI / 8 DO to 256 I/O modular (see variants)
- Protocols
- Modbus RTU/TCP
- CPU
- Industrial x86 dual-core
- Power supply
- 24 VDC
- Operating temperature
- -25 to 70 °C
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 1 nos
SCADA, RTU & plant controllersHampi5 variants
SampleSCADA, RTU & plant controllers Hampi · HAM-3C7 series
- I/O capacity
- 32 DI / 16 DO / 8 AI to 512 I/O modular (see variants)
- Protocols
- Modbus RTU/TCP
- CPU
- ARM Cortex-A9
- Power supply
- 48 VDC
- Operating temperature
- -10 to 60 °C
Lead time 8-10 weeks · Warranty 24 months from commissioning · MOQ 1 nos
SCADA, RTU & plant controllersChambal6 variants
SampleSCADA, RTU & plant controllers Chambal · CHA-E24 series
- I/O capacity
- 16 DI / 8 DO to 512 I/O modular (see variants)
- Protocols
- IEC 61850 server
- CPU
- ARM Cortex-A9
- Power supply
- 48 VDC
- Operating temperature
- -25 to 70 °C
Lead time 4-6 weeks · Warranty 36 months from supply · MOQ 2 nos
SCADA, RTU & plant controllersKanchi5 variants
SampleSCADA, RTU & plant controllers Kanchi · KAN-025 series
- I/O capacity
- 32 DI / 16 DO / 8 AI to 512 I/O modular (see variants)
- Protocols
- Modbus RTU/TCP
- CPU
- ARM Cortex-A9
- Power supply
- 48 VDC
- Operating temperature
- -25 to 70 °C
Lead time 8-10 weeks · Warranty 24 months from commissioning · MOQ 1 nos
SCADA, RTU & plant controllersVaigaispark6 variants
SampleSCADA, RTU & plant controllers Vaigaispark · VAI-026 series
- I/O capacity
- 16 DI / 8 DO to 512 I/O modular (see variants)
- Protocols
- IEC 61850 server
- CPU
- ARM Cortex-A9
- Power supply
- 48 VDC
- Operating temperature
- -25 to 70 °C
Lead time 8-10 weeks · Warranty 36 months from supply · MOQ 1 nos
SCADA, RTU & plant controllersOjascore3 variants
SampleSCADA, RTU & plant controllers Ojascore · OJA-026 series
- I/O capacity
- 16 DI / 8 DO to 64 DI / 32 DO / 16 AI (see variants)
- Protocols
- DNP3
- CPU
- Industrial x86 dual-core
- Power supply
- 48 VDC
- Operating temperature
- -25 to 70 °C
Lead time 4-6 weeks · Warranty 36 months from supply · MOQ 10 nos
SCADA, RTU & plant controllersVaigaispark5 variants
SampleSCADA, RTU & plant controllers Vaigaispark · VAI-3C2 series
- I/O capacity
- 16 DI / 8 DO to 256 I/O modular (see variants)
- Protocols
- Modbus RTU/TCP
- CPU
- Industrial x86 dual-core
- Power supply
- 48 VDC
- Operating temperature
- -25 to 70 °C
Lead time 8-10 weeks · Warranty 36 months from supply · MOQ 10 nos
SCADA, RTU & plant controllersKonkan3 variants
SampleSCADA, RTU & plant controllers Konkan · KON-E26 series
- I/O capacity
- 32 DI / 16 DO / 8 AI to 128 I/O modular (see variants)
- Protocols
- IEC 61850 server
- CPU
- ARM Cortex-A9
- Power supply
- 24 VDC
- Operating temperature
- -10 to 60 °C
Lead time 8-10 weeks · Warranty 24 months from commissioning · MOQ 10 nos
SCADA, RTU & plant controllersVaigaishakti5 variants
SampleSCADA, RTU & plant controllers Vaigaishakti · VAI-E23 series
- I/O capacity
- 16 DI / 8 DO to 256 I/O modular (see variants)
- Protocols
- Modbus RTU/TCP
- CPU
- Industrial x86 dual-core
- Power supply
- 24 VDC
- Operating temperature
- -10 to 60 °C
Lead time 8-10 weeks · Warranty 24 months from commissioning · MOQ 2 nos
SCADA, RTU & plant controllersNilgiri4 variants
SampleSCADA, RTU & plant controllers Nilgiri · NIL-3C8 series
- I/O capacity
- 64 DI / 32 DO / 16 AI to 512 I/O modular (see variants)
- Protocols
- Modbus RTU/TCP
- CPU
- ARM Cortex-A9
- Power supply
- 48 VDC
- Operating temperature
- -10 to 60 °C
Lead time 4-6 weeks · Warranty 36 months from supply · MOQ 1 nos
SCADA, RTU & plant controllersBeas3 variants
SampleSCADA, RTU & plant controllers Beas · BEA-E29 series
- I/O capacity
- 64 DI / 32 DO / 16 AI to 256 I/O modular (see variants)
- Protocols
- DNP3
- CPU
- ARM Cortex-A9
- Power supply
- 48 VDC
- Operating temperature
- -25 to 70 °C
Lead time 8-10 weeks · Warranty 24 months from commissioning · MOQ 1 nos
SCADA, RTU & plant controllersLonavalatamra6 variants
SampleSCADA, RTU & plant controllers Lonavalatamra · LON-268 series
- I/O capacity
- 16 DI / 8 DO to 512 I/O modular (see variants)
- Protocols
- Modbus RTU/TCP
- CPU
- ARM Cortex-A9
- Power supply
- 24 VDC
- Operating temperature
- -25 to 70 °C
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 2 nos
SCADA, RTU & plant controllersAjanta4 variants
SampleSCADA, RTU & plant controllers Ajanta · AJA-3C3 series
- I/O capacity
- 64 DI / 32 DO / 16 AI to 512 I/O modular (see variants)
- Protocols
- IEC 60870-5-101/104
- CPU
- ARM Cortex-A9
- Power supply
- 110-220 VDC/VAC
- Operating temperature
- -25 to 70 °C
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 5 nos
SCADA, RTU & plant controllersAwadh4 variants
SampleSCADA, RTU & plant controllers Awadh · AWA-C97 series
- I/O capacity
- 32 DI / 16 DO / 8 AI to 256 I/O modular (see variants)
- Protocols
- Modbus RTU/TCP
- CPU
- ARM Cortex-A9
- Power supply
- 48 VDC
- Operating temperature
- -10 to 60 °C
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 1 nos
SCADA, RTU & plant controllersPrabhacore5 variants
SampleSCADA, RTU & plant controllers Prabhacore · PRA-C93 series
- I/O capacity
- 16 DI / 8 DO to 256 I/O modular (see variants)
- Protocols
- IEC 60870-5-101/104
- CPU
- Industrial x86 dual-core
- Power supply
- 48 VDC
- Operating temperature
- -10 to 60 °C
Lead time 8-10 weeks · Warranty 36 months from supply · MOQ 1 nos
SCADA, RTU & plant controllersNilgiri4 variants
SampleSCADA, RTU & plant controllers Nilgiri · NIL-C93 series
- I/O capacity
- 64 DI / 32 DO / 16 AI to 512 I/O modular (see variants)
- Protocols
- IEC 60870-5-101/104
- CPU
- Industrial x86 dual-core
- Power supply
- 110-220 VDC/VAC
- Operating temperature
- -25 to 70 °C
Lead time 4-6 weeks · Warranty 36 months from supply · MOQ 5 nos
SCADA, RTU & plant controllersKalinga4 variants
SampleSCADA, RTU & plant controllers Kalinga · KAL-261 series
- I/O capacity
- 32 DI / 16 DO / 8 AI to 256 I/O modular (see variants)
- Protocols
- IEC 61850 server
- CPU
- ARM Cortex-A9
- Power supply
- 48 VDC
- Operating temperature
- -25 to 70 °C
Lead time 8-10 weeks · Warranty 24 months from commissioning · MOQ 5 nos
SCADA, RTU & plant controllersMagadh6 variants
SampleSCADA, RTU & plant controllers Magadh · MAG-269 series
- I/O capacity
- 16 DI / 8 DO to 512 I/O modular (see variants)
- Protocols
- IEC 61850 server
- CPU
- ARM Cortex-A9
- Power supply
- 24 VDC
- Operating temperature
- -10 to 60 °C
Lead time 4-6 weeks · Warranty 36 months from supply · MOQ 1 nos
SCADA, RTU & plant controllersFaradayline6 variants
SampleSCADA, RTU & plant controllers Faradayline · FAR-E28 series
- I/O capacity
- 16 DI / 8 DO to 512 I/O modular (see variants)
- Protocols
- DNP3
- CPU
- Industrial x86 dual-core
- Power supply
- 24 VDC
- Operating temperature
- -25 to 70 °C
Lead time 4-6 weeks · Warranty 36 months from supply · MOQ 10 nos
SCADA, RTU & plant controllersKonarkanant5 variants
SampleSCADA, RTU & plant controllers Konarkanant · KON-E24 series
- I/O capacity
- 16 DI / 8 DO to 256 I/O modular (see variants)
- Protocols
- IEC 60870-5-101/104
- CPU
- ARM Cortex-A9
- Power supply
- 110-220 VDC/VAC
- Operating temperature
- -10 to 60 °C
Lead time 8-10 weeks · Warranty 36 months from supply · MOQ 1 nos
SCADA, RTU & plant controllersAiravatmax3 variants
SampleSCADA, RTU & plant controllers Airavatmax · AIR-C98 series
- I/O capacity
- 64 DI / 32 DO / 16 AI to 256 I/O modular (see variants)
- Protocols
- IEC 60870-5-101/104
- CPU
- Industrial x86 dual-core
- Power supply
- 24 VDC
- Operating temperature
- -10 to 60 °C
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 10 nos