CEMS & ambient air monitoringAmaravatitej3 variants
SampleCEMS & ambient air monitoring Amaravatitej · AMA-CF9 series
- Parameters monitored
- PM + SO2 + NOx + O2 to Full CEMS 8 parameters (see variants)
- Measurement method
- Extractive hot-wet
- Particulate sensor
- Opacity
- Gas analyser
- UV fluorescence
- Data logging
- Modbus TCP
Lead time 6-8 weeks · Warranty 12 months from commissioning · MOQ 1 set
SCR / SNCR NOx controlSaurashtra4 variants
SampleSCR / SNCR NOx control Saurashtra · SAU-459 series
- Flue gas flow
- 50000 Nm3/h to 500000 Nm3/h (see variants)
- Technology
- SNCR
- NOx removal efficiency
- 85%
- Reagent
- Urea solution 40%
- Catalyst
- Honeycomb V2O5-WO3/TiO2
Lead time 16-24 weeks · Warranty 12 months from commissioning · MOQ 10 set
CEMS & ambient air monitoringAkshaymark6 variants
SampleCEMS & ambient air monitoring Akshaymark · AKS-8B8 series
- Parameters monitored
- PM only to Full CEMS 8 parameters (see variants)
- Measurement method
- In-situ
- Particulate sensor
- Beta attenuation
- Gas analyser
- UV fluorescence
- Data logging
- 4-20 mA
Lead time 6-8 weeks · Warranty 24 months on analysers · MOQ 1 set
SCR / SNCR NOx controlParamline4 variants
SampleSCR / SNCR NOx control Paramline · PAR-9A4 series
- Flue gas flow
- 20000 Nm3/h to 250000 Nm3/h (see variants)
- Technology
- SCR
- NOx removal efficiency
- 70%
- Reagent
- Urea solution 40%
- Catalyst
- Plate type
Lead time 16-24 weeks · Warranty 24000 operating hours on catalyst · MOQ 1 set
SCR / SNCR NOx controlAwadhshikhar4 variants
SampleSCR / SNCR NOx control Awadhshikhar · AWA-9A5 series
- Flue gas flow
- 50000 Nm3/h to 500000 Nm3/h (see variants)
- Technology
- Hybrid
- NOx removal efficiency
- 85%
- Reagent
- Ammonia 25%
- Catalyst
- Plate type
Lead time 16-24 weeks · Warranty 24000 operating hours on catalyst · MOQ 5 set
Ash utilisationMunnarspark5 variants
Munnarspark · MUN-461 series
- Fly ash fineness (Blaine)
- 250 sq m/kg to 400 sq m/kg (see variants)
- Source
- Pond ash
- Grade
- Siliceous Grade 1
- Loss on ignition
- Below 5%
- Moisture
- Below 1%
Lead time 1-2 weeks · Warranty Test certificate per lot · MOQ 2 MT
ESP & bag filtersAmaravatitej5 variants
Amaravatitej · AMA-F06 series
- Gas flow rate
- 50000 Am3/h to 1000000 Am3/h (see variants)
- Outlet emission
- Below 50 mg/Nm3
- Inlet temperature
- Up to 250 deg C
- Filter media
- Polyester
- Cleaning
- Pulse jet
Lead time 12-16 weeks · Warranty 12 months from commissioning · MOQ 1 set
Noise controlSaurashtra6 variants
Saurashtra · SAU-3E1 series
- Insertion loss
- 15 dB to 40 dB (see variants)
- Equipment served
- DG set
- Panel construction
- Double skin MS
- Infill
- PU foam
- Sheet thickness
- 1.6 mm
Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos
SCR / SNCR NOx controlSaurashtra5 variants
SampleSCR / SNCR NOx control Saurashtra · SAU-9A7 series
- Flue gas flow
- 20000 Nm3/h to 500000 Nm3/h (see variants)
- Technology
- Hybrid
- NOx removal efficiency
- 90%
- Reagent
- Urea solution 40%
- Catalyst
- Plate type
Lead time 30-44 weeks · Warranty 12 months from commissioning · MOQ 1 set
SCR / SNCR NOx controlAmaravatitej5 variants
SampleSCR / SNCR NOx control Amaravatitej · AMA-454 series
- Flue gas flow
- 50000 Nm3/h to 1000000 Nm3/h (see variants)
- Technology
- SCR
- NOx removal efficiency
- 90%
- Reagent
- Urea solution 40%
- Catalyst
- Honeycomb V2O5-WO3/TiO2
Lead time 30-44 weeks · Warranty 12 months from commissioning · MOQ 5 set
Flue-gas desulphurisation (FGD)Saurashtra5 variants
SampleFlue-gas desulphurisation (FGD) Saurashtra · SAU-404 series
- Boiler size
- 60 MW to 500 MW (see variants)
- Technology
- Dry sorbent
- SO2 removal efficiency
- 95%
- Inlet SO2
- Up to 2500 mg/Nm3
- Absorber material
- Alloy lined
Lead time 24-36 weeks · Warranty 12 months from commissioning · MOQ 10 set
CEMS & ambient air monitoringSaurashtra3 variants
SampleCEMS & ambient air monitoring Saurashtra · SAU-109 series
- Parameters monitored
- PM + SO2 + NOx to PM + gases + flow (see variants)
- Measurement method
- Dilution extractive
- Particulate sensor
- Beta attenuation
- Gas analyser
- UV fluorescence
- Data logging
- 4-20 mA
Lead time 10-14 weeks · Warranty 24 months on analysers · MOQ 1 set
CEMS & ambient air monitoringHertzline6 variants
SampleCEMS & ambient air monitoring Hertzline · HER-CF2 series
- Parameters monitored
- PM only to Full CEMS 8 parameters (see variants)
- Measurement method
- Dilution extractive
- Particulate sensor
- Opacity
- Gas analyser
- UV fluorescence
- Data logging
- 4-20 mA
Lead time 6-8 weeks · Warranty 24 months on analysers · MOQ 10 set
ESP & bag filtersMahabaleshwarjoule6 variants
Mahabaleshwarjoule · MAH-8F3 series
- Gas flow rate
- 10000 Am3/h to 500000 Am3/h (see variants)
- Outlet emission
- Below 50 mg/Nm3
- Inlet temperature
- Up to 180 deg C
- Filter media
- PTFE membrane
- Cleaning
- Reverse air
Lead time 20-28 weeks · Warranty 24 months on mechanical parts · MOQ 1 set
ESP & bag filtersAwadhshikhar3 variants
Awadhshikhar · AWA-594 series
- Gas flow rate
- 250000 Am3/h to 1000000 Am3/h (see variants)
- Outlet emission
- Below 50 mg/Nm3
- Inlet temperature
- Up to 250 deg C
- Filter media
- Polyester
- Cleaning
- Pulse jet
Lead time 20-28 weeks · Warranty 12 months from commissioning · MOQ 1 set
Ash utilisationMahanadi5 variants
Mahanadi · MAH-568 series
- Fly ash fineness (Blaine)
- 250 sq m/kg to 400 sq m/kg (see variants)
- Source
- Bottom ash
- Grade
- Siliceous Grade 2
- Loss on ignition
- Below 2%
- Moisture
- Below 1%
Lead time 1-2 weeks · Warranty Test certificate per lot · MOQ 1 MT
Ash utilisationAmaravatitej3 variants
Amaravatitej · AMA-5C1 series
- Fly ash fineness (Blaine)
- 300 sq m/kg to 350 sq m/kg (see variants)
- Source
- Pond ash
- Grade
- Siliceous Grade 1
- Loss on ignition
- Below 5%
- Moisture
- Below 5%
Lead time 3-7 days · Warranty Test certificate per lot · MOQ 1 MT
Flue-gas desulphurisation (FGD)Paramline4 variants
SampleFlue-gas desulphurisation (FGD) Paramline · PAR-771 series
- Boiler size
- 10 MW to 120 MW (see variants)
- Technology
- Semi-dry
- SO2 removal efficiency
- 90%
- Inlet SO2
- Up to 2500 mg/Nm3
- Absorber material
- Alloy lined
Lead time 40-60 weeks · Warranty 12 months from commissioning · MOQ 1 set
Noise controlMahanadi4 variants
Mahanadi · MAH-D02 series
- Insertion loss
- 15 dB to 30 dB (see variants)
- Equipment served
- DG set
- Panel construction
- GI perforated with rockwool
- Infill
- PU foam
- Sheet thickness
- 2.0 mm
Lead time 6-8 weeks · Warranty 12 months from supply · MOQ 1 nos
Ash utilisationKamrup4 variants
Kamrup · KAM-394 series
- Fly ash fineness (Blaine)
- 300 sq m/kg to 400 sq m/kg (see variants)
- Source
- Pond ash
- Grade
- Siliceous Grade 1
- Loss on ignition
- Below 2%
- Moisture
- Below 5%
Lead time 3-7 days · Warranty Test certificate per lot · MOQ 5 MT
CEMS & ambient air monitoringMahabaleshwarjoule4 variants
SampleCEMS & ambient air monitoring Mahabaleshwarjoule · MAH-CF3 series
- Parameters monitored
- PM + SO2 + NOx to Full CEMS 8 parameters (see variants)
- Measurement method
- In-situ
- Particulate sensor
- Beta attenuation
- Gas analyser
- Chemiluminescence
- Data logging
- 4-20 mA
Lead time 6-8 weeks · Warranty 12 months from commissioning · MOQ 1 set
Flue-gas desulphurisation (FGD)Hertzline4 variants
SampleFlue-gas desulphurisation (FGD) Hertzline · HER-775 series
- Boiler size
- 25 MW to 210 MW (see variants)
- Technology
- Semi-dry
- SO2 removal efficiency
- 90%
- Inlet SO2
- Up to 2500 mg/Nm3
- Absorber material
- Rubber lined carbon steel
Lead time 40-60 weeks · Warranty 24 months performance guarantee · MOQ 2 set
ESP & bag filtersMahanadi4 variants
Mahanadi · MAH-458 series
- Gas flow rate
- 10000 Am3/h to 100000 Am3/h (see variants)
- Outlet emission
- Below 50 mg/Nm3
- Inlet temperature
- Up to 180 deg C
- Filter media
- PPS felt
- Cleaning
- Reverse air
Lead time 20-28 weeks · Warranty 12 months from commissioning · MOQ 5 set
CEMS & ambient air monitoringMunnarspark4 variants
SampleCEMS & ambient air monitoring Munnarspark · MUN-6D9 series
- Parameters monitored
- PM + SO2 + NOx to Full CEMS 8 parameters (see variants)
- Measurement method
- Extractive hot-wet
- Particulate sensor
- Beta attenuation
- Gas analyser
- UV fluorescence
- Data logging
- Modbus TCP
Lead time 6-8 weeks · Warranty 24 months on analysers · MOQ 10 set