Earthing & auxiliary transformersAwadhakshay6 variants
SampleEarthing & auxiliary transformers Awadhakshay · AWA-2C6 series
- Rating
- 50 kVA to 1600 kVA (see variants)
- Type
- Station service
- Primary voltage
- 11 kV
- Secondary voltage
- 3.3 kV
- Short-time rating
- 10 s
Lead time 3-5 weeks · Warranty 24 months · MOQ 1 nos
Compact secondary substationsBundel5 variants
SampleCompact secondary substations Bundel · BUN-9A6 series
- Transformer rating
- 250 kVA to 1600 kVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- 0.433 kV
- HV equipment
- Fuse switch
- Transformer type
- Cast resin dry
Lead time 6-8 weeks · Warranty 24 months · MOQ 1 nos
Distribution transformersTejmark4 variants
SampleDistribution transformers Tejmark · TEJ-5B7 series
- Rating
- 16 kVA to 100 kVA (see variants)
- Voltage ratio
- 22/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Level 2
Lead time 2-3 weeks · Warranty 18 months from supply · MOQ 10 nos
Instrument transformers (CT, PT, CVT)Narmadapushpak5 variants
SampleInstrument transformers (CT, PT, CVT) Narmadapushpak · NAR-797 series
- System voltage
- 33 kV to 400 kV (see variants)
- Type
- Current transformer
- Ratio
- 400-800/1 A
- Accuracy class
- 0.5
- Burden
- 30 VA
Lead time 4-6 weeks · Warranty 18 months · MOQ 1 nos
Earthing & auxiliary transformersSamarthtek6 variants
SampleEarthing & auxiliary transformers Samarthtek · SAM-F35 series
- Rating
- 100 kVA to 3150 kVA (see variants)
- Type
- Auxiliary (Dyn11)
- Primary voltage
- 11 kV
- Secondary voltage
- 3.3 kV
- Short-time rating
- 10 s
Lead time 8-10 weeks · Warranty 24 months · MOQ 10 nos
Transformer monitoring (online DGA, bushing monitors)Hampiohm4 variants
SampleTransformer monitoring (online DGA, bushing monitors) Hampiohm · HAM-F37 series
- Gases monitored
- Single gas (H2) to 9 gases (see variants)
- Gases measured
- H2, CO, C2H2
- Technology
- Infrared
- Measurement interval
- 24 hours
- Accuracy
- +/- 10%
Lead time 8-10 weeks · Warranty 24 months · MOQ 2 nos
Instrument transformers (CT, PT, CVT)Sabarmati5 variants
SampleInstrument transformers (CT, PT, CVT) Sabarmati · SAB-794 series
- System voltage
- 11 kV to 220 kV (see variants)
- Type
- Combined CT-PT
- Ratio
- 400-800/1 A
- Accuracy class
- 0.5
- Burden
- 50 VA
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 10 nos
Bushings, OLTC & transformer accessoriesKonark5 variants
SampleBushings, OLTC & transformer accessories Konark · KON-435 series
- Voltage class
- 11 kV to 220 kV (see variants)
- Component
- PRV
- Current rating
- 3150 A
- Insulation type
- RIP
- Creepage
- 25 mm/kV
Lead time 12-20 weeks · Warranty 24 months · MOQ 1 nos
Instrument transformers (CT, PT, CVT)Samarthtek4 variants
SampleInstrument transformers (CT, PT, CVT) Samarthtek · SAM-792 series
- System voltage
- 33 kV to 220 kV (see variants)
- Type
- CVT
- Ratio
- 100-200/1 A
- Accuracy class
- PS
- Burden
- 50 VA
Lead time 10-14 weeks · Warranty 18 months · MOQ 1 nos
Mobile substationsBrahmaputra4 variants
Brahmaputra · BRA-8E8 series
- Transformer rating
- 20 MVA to 63 MVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- 11 kV
- Chassis
- Low-bed trailer
- Primary switchgear
- AIS disconnector and breaker
Lead time 16-24 weeks · Warranty 24 months · MOQ 2 nos
Power transformersKakatiya3 variants
Kakatiya · KAK-1D2 series
- Rating
- 50 MVA to 160 MVA (see variants)
- Voltage ratio
- 400/220 kV
- Cooling
- ONAN/ONAF
- Vector group
- Dyn11
- Tap changer
- OLTC 1.25% steps
Lead time 16-24 weeks · Warranty 24 months from commissioning · MOQ 10 nos
Power transformersBundel5 variants
Bundel · BUN-D21 series
- Rating
- 10 MVA to 100 MVA (see variants)
- Voltage ratio
- 33/11 kV
- Cooling
- ONAN/ONAF/OFAF
- Vector group
- YNyn0 d11
- Tap changer
- OLTC +/- 10% in 16 steps
Lead time 30-40 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Transformer monitoring (online DGA, bushing monitors)Nilgirispark3 variants
SampleTransformer monitoring (online DGA, bushing monitors) Nilgirispark · NIL-F33 series
- Gases monitored
- 3 gases to 9 gases (see variants)
- Gases measured
- H2, CO, CO2, CH4, C2H2, C2H4, C2H6
- Technology
- Photoacoustic
- Measurement interval
- 24 hours
- Accuracy
- +/- 10%
Lead time 4-6 weeks · Warranty 36 months with AMC · MOQ 1 nos
Compact secondary substationsKonark6 variants
SampleCompact secondary substations Konark · KON-329 series
- Transformer rating
- 100 kVA to 1600 kVA (see variants)
- Primary voltage
- 11 kV
- Secondary voltage
- 0.69 kV
- HV equipment
- Ring main unit
- Transformer type
- Cast resin dry
Lead time 10-14 weeks · Warranty 18 months · MOQ 10 nos
Bushings, OLTC & transformer accessoriesTamratek3 variants
SampleBushings, OLTC & transformer accessories Tamratek · TAM-4F3 series
- Voltage class
- 33 kV to 132 kV (see variants)
- Component
- Bushing
- Current rating
- 630 A
- Insulation type
- RIP
- Creepage
- 25 mm/kV
Lead time 3-6 weeks · Warranty 24 months · MOQ 1 nos
Power transformersTejmark5 variants
Tejmark · TEJ-277 series
- Rating
- 31.5 MVA to 315 MVA (see variants)
- Voltage ratio
- 220/132 kV
- Cooling
- ONAN/ONAF/OFAF
- Vector group
- Dyn11
- Tap changer
- OLTC 1.25% steps
Lead time 30-40 weeks · Warranty 36 months from supply · MOQ 1 nos
Earthing & auxiliary transformersJalline5 variants
SampleEarthing & auxiliary transformers Jalline · JAL-C07 series
- Rating
- 100 kVA to 1600 kVA (see variants)
- Type
- Auxiliary (Dyn11)
- Primary voltage
- 11 kV
- Secondary voltage
- 3.3 kV
- Short-time rating
- 30 s
Lead time 3-5 weeks · Warranty 18 months · MOQ 1 nos
Bushings, OLTC & transformer accessoriesTejmark5 variants
SampleBushings, OLTC & transformer accessories Tejmark · TEJ-439 series
- Voltage class
- 11 kV to 220 kV (see variants)
- Component
- Buchholz relay
- Current rating
- 1250 A
- Insulation type
- RIP
- Creepage
- 31 mm/kV
Lead time 3-6 weeks · Warranty 18 months · MOQ 10 nos
Inverter duty transformersCoromandel6 variants
SampleInverter duty transformers Coromandel · COR-FF1 series
- Rating
- 3.15 MVA to 12.5 MVA (see variants)
- Voltage ratio
- 33/0.8 kV
- Windings
- Two
- Vector group
- Dyn11
- Cooling
- ONAN
Lead time 6-8 weeks · Warranty 24 months from commissioning · MOQ 5 nos
Instrument transformers (CT, PT, CVT)Tamratek4 variants
SampleInstrument transformers (CT, PT, CVT) Tamratek · TAM-0F1 series
- System voltage
- 66 kV to 400 kV (see variants)
- Type
- Voltage transformer
- Ratio
- 132 kV/110 V
- Accuracy class
- PS
- Burden
- 30 VA
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Distribution transformersAmaravati6 variants
SampleDistribution transformers Amaravati · AMA-558 series
- Rating
- 16 kVA to 315 kVA (see variants)
- Voltage ratio
- 33/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Amorphous
Lead time 2-3 weeks · Warranty 12 months from commissioning · MOQ 5 nos
Furnace & rectifier transformersThanjavurprakash6 variants
SampleFurnace & rectifier transformers Thanjavurprakash · THA-914 series
- Rating
- 2 MVA to 60 MVA (see variants)
- Primary voltage
- 66 kV
- Secondary voltage
- Up to 1000 V
- Application
- Rectifier
- Cooling
- ONAN/ONAF
Lead time 28-36 weeks · Warranty 36 months from supply · MOQ 1 nos
Inverter duty transformersHampiohm5 variants
SampleInverter duty transformers Hampiohm · HAM-F52 series
- Rating
- 1 MVA to 5 MVA (see variants)
- Voltage ratio
- 33/0.69/0.69 kV
- Windings
- Three (split LV)
- Vector group
- Dy11y11
- Cooling
- ONAN
Lead time 10-14 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Shunt & series reactorsKutchwatt5 variants
SampleShunt & series reactors Kutchwatt · KUT-FC7 series
- Rating
- 10 MVAr to 125 MVAr (see variants)
- System voltage
- 220 kV
- Type
- Series
- Construction
- Air-core dry
- Phases
- Single
Lead time 40-50 weeks · Warranty 24 months from commissioning · MOQ 1 nos