Mobile substationsAmaravati5 variants
Amaravati · AMA-344 series
- Transformer rating
- 10 MVA to 63 MVA (see variants)
- Primary voltage
- 66 kV
- Secondary voltage
- 11 kV
- Chassis
- Container
- Primary switchgear
- GIS bay
Lead time 30-40 weeks · Warranty 24 months · MOQ 1 nos
Furnace & rectifier transformersSabarmati4 variants
SampleFurnace & rectifier transformers Sabarmati · SAB-695 series
- Rating
- 5 MVA to 40 MVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- Up to 400 V DC rectified
- Application
- EAF
- Cooling
- ONAN/ONAF
Lead time 28-36 weeks · Warranty 24 months · MOQ 1 nos
Transformer monitoring (online DGA, bushing monitors)Tejmark3 variants
SampleTransformer monitoring (online DGA, bushing monitors) Tejmark · TEJ-9F1 series
- Gases monitored
- 3 gases to 9 gases (see variants)
- Gases measured
- H2, CO
- Technology
- Infrared
- Measurement interval
- 4 hours
- Accuracy
- +/- 5%
Lead time 4-6 weeks · Warranty 24 months · MOQ 2 nos
Transformer monitoring (online DGA, bushing monitors)Bundel3 variants
SampleTransformer monitoring (online DGA, bushing monitors) Bundel · BUN-9F1 series
- Gases monitored
- 3 gases to 9 gases (see variants)
- Gases measured
- H2, CO, CO2, CH4, C2H2, C2H4, C2H6
- Technology
- Gas chromatography
- Measurement interval
- 24 hours
- Accuracy
- +/- 5%
Lead time 4-6 weeks · Warranty 36 months with AMC · MOQ 2 nos
Bushings, OLTC & transformer accessoriesAwadhakshay6 variants
SampleBushings, OLTC & transformer accessories Awadhakshay · AWA-283 series
- Voltage class
- 11 kV to 400 kV (see variants)
- Component
- Bushing
- Current rating
- 3150 A
- Insulation type
- RIS
- Creepage
- 31 mm/kV
Lead time 12-20 weeks · Warranty 24 months · MOQ 5 nos
Earthing & auxiliary transformersKaverianant5 variants
SampleEarthing & auxiliary transformers Kaverianant · KAV-FC8 series
- Rating
- 315 kVA to 3150 kVA (see variants)
- Type
- Auxiliary (Dyn11)
- Primary voltage
- 33 kV
- Secondary voltage
- 0.433 kV
- Short-time rating
- 30 s
Lead time 8-10 weeks · Warranty 24 months · MOQ 1 nos
Compact secondary substationsSabarmati6 variants
SampleCompact secondary substations Sabarmati · SAB-113 series
- Transformer rating
- 100 kVA to 1600 kVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- 0.433 kV
- HV equipment
- VCB panel
- Transformer type
- Oil-immersed
Lead time 10-14 weeks · Warranty 18 months · MOQ 1 nos
Instrument transformers (CT, PT, CVT)Madurai5 variants
SampleInstrument transformers (CT, PT, CVT) Madurai · MAD-C47 series
- System voltage
- 33 kV to 400 kV (see variants)
- Type
- Current transformer
- Ratio
- 100-200/1 A
- Accuracy class
- PS
- Burden
- 15 VA
Lead time 10-14 weeks · Warranty 24 months from commissioning · MOQ 2 nos
Transformer monitoring (online DGA, bushing monitors)Chambal4 variants
SampleTransformer monitoring (online DGA, bushing monitors) Chambal · CHA-9F5 series
- Gases monitored
- Single gas (H2) to 9 gases (see variants)
- Gases measured
- H2, CO
- Technology
- Infrared
- Measurement interval
- 1 hour
- Accuracy
- +/- 5%
Lead time 8-10 weeks · Warranty 36 months with AMC · MOQ 1 nos
Shunt & series reactorsGodavari4 variants
SampleShunt & series reactors Godavari · GOD-5D4 series
- Rating
- 50 MVAr to 200 MVAr (see variants)
- System voltage
- 132 kV
- Type
- Neutral
- Construction
- Oil-immersed gapped core
- Phases
- Three
Lead time 40-50 weeks · Warranty 36 months from supply · MOQ 2 nos
Distribution transformersAwadhakshay4 variants
SampleDistribution transformers Awadhakshay · AWA-487 series
- Rating
- 315 kVA to 2500 kVA (see variants)
- Voltage ratio
- 22/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Amorphous
Lead time 2-3 weeks · Warranty 12 months from commissioning · MOQ 10 nos
Power transformersChambal5 variants
Chambal · CHA-358 series
- Rating
- 50 MVA to 500 MVA (see variants)
- Voltage ratio
- 132/33 kV
- Cooling
- ONAN/ONAF
- Vector group
- YNa0d11
- Tap changer
- OLTC 1.25% steps
Lead time 30-40 weeks · Warranty 24 months from commissioning · MOQ 5 nos
Inverter duty transformersSabarmati4 variants
SampleInverter duty transformers Sabarmati · SAB-F56 series
- Rating
- 2.5 MVA to 5 MVA (see variants)
- Voltage ratio
- 33/0.69 kV
- Windings
- Three (split LV)
- Vector group
- Dy11y11
- Cooling
- ONAN
Lead time 10-14 weeks · Warranty 24 months from commissioning · MOQ 2 nos
Dry-type transformersBundel6 variants
SampleDry-type transformers Bundel · BUN-F94 series
- Rating
- 100 kVA to 2500 kVA (see variants)
- Voltage ratio
- 33/0.433 kV
- Technology
- Cast resin
- Insulation class
- Class F
- Cooling
- AN/AF
Lead time 8-10 weeks · Warranty 24 months · MOQ 1 nos
Shunt & series reactorsKaverianant4 variants
SampleShunt & series reactors Kaverianant · KAV-756 series
- Rating
- 50 MVAr to 200 MVAr (see variants)
- System voltage
- 400 kV
- Type
- Series
- Construction
- Oil-immersed gapped core
- Phases
- Three
Lead time 40-50 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Shunt & series reactorsTamratek3 variants
SampleShunt & series reactors Tamratek · TAM-5D4 series
- Rating
- 80 MVAr to 200 MVAr (see variants)
- System voltage
- 220 kV
- Type
- Neutral
- Construction
- Air-core dry
- Phases
- Three
Lead time 20-28 weeks · Warranty 36 months from supply · MOQ 1 nos
Mobile substationsKakatiya4 variants
Kakatiya · KAK-8E2 series
- Transformer rating
- 5 MVA to 31.5 MVA (see variants)
- Primary voltage
- 220 kV
- Secondary voltage
- 33 kV
- Chassis
- Container
- Primary switchgear
- AIS disconnector and breaker
Lead time 30-40 weeks · Warranty 36 months · MOQ 2 nos
Power transformersAwadhakshay4 variants
Awadhakshay · AWA-D21 series
- Rating
- 31.5 MVA to 160 MVA (see variants)
- Voltage ratio
- 220/132 kV
- Cooling
- ONAN/ONAF
- Vector group
- Dyn11
- Tap changer
- OLTC +/- 10% in 16 steps
Lead time 16-24 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Inverter duty transformersSabarmati5 variants
SampleInverter duty transformers Sabarmati · SAB-209 series
- Rating
- 1 MVA to 5 MVA (see variants)
- Voltage ratio
- 22/0.69 kV
- Windings
- Three (split LV)
- Vector group
- Dy11y11
- Cooling
- ONAN
Lead time 6-8 weeks · Warranty 36 months from supply · MOQ 1 nos
Power transformersHampiohm4 variants
Hampiohm · HAM-F77 series
- Rating
- 20 MVA to 100 MVA (see variants)
- Voltage ratio
- 400/220 kV
- Cooling
- ONAN/ONAF
- Vector group
- YNyn0 d11
- Tap changer
- OLTC 1.25% steps
Lead time 30-40 weeks · Warranty 24 months from commissioning · MOQ 10 nos
Shunt & series reactorsCoorgswarna6 variants
SampleShunt & series reactors Coorgswarna · COO-2B5 series
- Rating
- 5 MVAr to 125 MVAr (see variants)
- System voltage
- 400 kV
- Type
- Series
- Construction
- Air-core dry
- Phases
- Single
Lead time 20-28 weeks · Warranty 24 months from commissioning · MOQ 2 nos
Mobile substationsBundel4 variants
Bundel · BUN-7D3 series
- Transformer rating
- 10 MVA to 50 MVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- 33 kV
- Chassis
- Low-bed trailer
- Primary switchgear
- AIS disconnector and breaker
Lead time 30-40 weeks · Warranty 36 months · MOQ 5 nos
Instrument transformers (CT, PT, CVT)Awadhakshay6 variants
SampleInstrument transformers (CT, PT, CVT) Awadhakshay · AWA-BD7 series
- System voltage
- 11 kV to 400 kV (see variants)
- Type
- CVT
- Ratio
- 1200-2400/1 A
- Accuracy class
- 5P20
- Burden
- 30 VA
Lead time 10-14 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Compact secondary substationsKaverianant4 variants
SampleCompact secondary substations Kaverianant · KAV-6C2 series
- Transformer rating
- 630 kVA to 2000 kVA (see variants)
- Primary voltage
- 11 kV
- Secondary voltage
- 0.69 kV
- HV equipment
- Ring main unit
- Transformer type
- Oil-immersed
Lead time 6-8 weeks · Warranty 18 months · MOQ 10 nos