Furnace & rectifier transformersCoorgswarna4 variants
SampleFurnace & rectifier transformers Coorgswarna · COO-918 series
- Rating
- 2 MVA to 20 MVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- Up to 1000 V
- Application
- SAF
- Cooling
- OFWF
Lead time 16-20 weeks · Warranty 24 months · MOQ 10 nos
Bushings, OLTC & transformer accessoriesNilgirispark3 variants
SampleBushings, OLTC & transformer accessories Nilgirispark · NIL-AD3 series
- Voltage class
- 11 kV to 66 kV (see variants)
- Component
- PRV
- Current rating
- 3150 A
- Insulation type
- RIS
- Creepage
- 31 mm/kV
Lead time 3-6 weeks · Warranty 24 months · MOQ 2 nos
Inverter duty transformersNarmadapushpak3 variants
SampleInverter duty transformers Narmadapushpak · NAR-FF8 series
- Rating
- 5 MVA to 10 MVA (see variants)
- Voltage ratio
- 33/0.69/0.69 kV
- Windings
- Three (split LV)
- Vector group
- Dy11y11
- Cooling
- ONAN
Lead time 6-8 weeks · Warranty 36 months from supply · MOQ 2 nos
Earthing & auxiliary transformersKonark6 variants
SampleEarthing & auxiliary transformers Konark · KON-2C6 series
- Rating
- 50 kVA to 1600 kVA (see variants)
- Type
- Earthing (zig-zag)
- Primary voltage
- 132 kV
- Secondary voltage
- 3.3 kV
- Short-time rating
- 30 s
Lead time 3-5 weeks · Warranty 18 months · MOQ 1 nos
Bushings, OLTC & transformer accessoriesMauryajal4 variants
SampleBushings, OLTC & transformer accessories Mauryajal · MAU-173 series
- Voltage class
- 33 kV to 220 kV (see variants)
- Component
- Radiator
- Current rating
- 630 A
- Insulation type
- RIP
- Creepage
- 31 mm/kV
Lead time 3-6 weeks · Warranty 18 months · MOQ 1 nos
Shunt & series reactorsKonark3 variants
SampleShunt & series reactors Konark · KON-757 series
- Rating
- 80 MVAr to 200 MVAr (see variants)
- System voltage
- 220 kV
- Type
- Series
- Construction
- Oil-immersed gapped core
- Phases
- Single
Lead time 40-50 weeks · Warranty 36 months from supply · MOQ 10 nos
Power transformersGodavari4 variants
Godavari · GOD-D27 series
- Rating
- 31.5 MVA to 160 MVA (see variants)
- Voltage ratio
- 66/11 kV
- Cooling
- ONAN/ONAF
- Vector group
- YNa0d11
- Tap changer
- OLTC +/- 10% in 16 steps
Lead time 30-40 weeks · Warranty 36 months from supply · MOQ 1 nos
Distribution transformersSabarmati6 variants
SampleDistribution transformers Sabarmati · SAB-551 series
- Rating
- 100 kVA to 2500 kVA (see variants)
- Voltage ratio
- 22/0.433 kV
- Vector group
- Dyn11
- Cooling
- ONAN
- Energy efficiency level
- Level 2
Lead time 2-3 weeks · Warranty 12 months from commissioning · MOQ 5 nos
Transformer monitoring (online DGA, bushing monitors)Mauryajal4 variants
SampleTransformer monitoring (online DGA, bushing monitors) Mauryajal · MAU-387 series
- Gases monitored
- Single gas (H2) to 9 gases (see variants)
- Gases measured
- H2, CO, C2H2
- Technology
- Infrared
- Measurement interval
- 4 hours
- Accuracy
- +/- 5%
Lead time 4-6 weeks · Warranty 24 months · MOQ 5 nos
Earthing & auxiliary transformersGodavari6 variants
SampleEarthing & auxiliary transformers Godavari · GOD-A88 series
- Rating
- 100 kVA to 3150 kVA (see variants)
- Type
- Earthing (zig-zag)
- Primary voltage
- 11 kV
- Secondary voltage
- 0.433 kV
- Short-time rating
- 10 s
Lead time 8-10 weeks · Warranty 18 months · MOQ 2 nos
Shunt & series reactorsGodavari4 variants
SampleShunt & series reactors Godavari · GOD-FC8 series
- Rating
- 50 MVAr to 200 MVAr (see variants)
- System voltage
- 132 kV
- Type
- Shunt
- Construction
- Oil-immersed gapped core
- Phases
- Three
Lead time 20-28 weeks · Warranty 36 months from supply · MOQ 1 nos
Dry-type transformersAjantajyoti5 variants
SampleDry-type transformers Ajantajyoti · AJA-F95 series
- Rating
- 250 kVA to 2500 kVA (see variants)
- Voltage ratio
- 33/0.433 kV
- Technology
- Cast resin
- Insulation class
- Class F
- Cooling
- AN/AF
Lead time 8-10 weeks · Warranty 24 months · MOQ 1 nos
Shunt & series reactorsCoorgswarna5 variants
SampleShunt & series reactors Coorgswarna · COO-5D6 series
- Rating
- 25 MVAr to 200 MVAr (see variants)
- System voltage
- 400 kV
- Type
- Neutral
- Construction
- Oil-immersed gapped core
- Phases
- Single
Lead time 20-28 weeks · Warranty 24 months from commissioning · MOQ 5 nos
Instrument transformers (CT, PT, CVT)Madurai3 variants
SampleInstrument transformers (CT, PT, CVT) Madurai · MAD-BD4 series
- System voltage
- 33 kV to 132 kV (see variants)
- Type
- CVT
- Ratio
- 1200-2400/1 A
- Accuracy class
- 0.5
- Burden
- 30 VA
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 5 nos
Inverter duty transformersKutchwatt6 variants
SampleInverter duty transformers Kutchwatt · KUT-7B7 series
- Rating
- 3.15 MVA to 12.5 MVA (see variants)
- Voltage ratio
- 33/0.69 kV
- Windings
- Two
- Vector group
- Dy11y11
- Cooling
- ONAN
Lead time 10-14 weeks · Warranty 36 months from supply · MOQ 10 nos
Mobile substationsKaverianant5 variants
Kaverianant · KAV-033 series
- Transformer rating
- 10 MVA to 63 MVA (see variants)
- Primary voltage
- 220 kV
- Secondary voltage
- 11 kV
- Chassis
- Skid
- Primary switchgear
- GIS bay
Lead time 30-40 weeks · Warranty 24 months · MOQ 1 nos
Instrument transformers (CT, PT, CVT)Kakatiya6 variants
SampleInstrument transformers (CT, PT, CVT) Kakatiya · KAK-C46 series
- System voltage
- 11 kV to 400 kV (see variants)
- Type
- Combined CT-PT
- Ratio
- 1200-2400/1 A
- Accuracy class
- 0.2S
- Burden
- 15 VA
Lead time 4-6 weeks · Warranty 24 months from commissioning · MOQ 5 nos
Dry-type transformersNilgirispark3 variants
SampleDry-type transformers Nilgirispark · NIL-F94 series
- Rating
- 100 kVA to 500 kVA (see variants)
- Voltage ratio
- 11/0.433 kV
- Technology
- VPI
- Insulation class
- Class H
- Cooling
- AN/AF
Lead time 4-6 weeks · Warranty 36 months · MOQ 2 nos
Compact secondary substationsAmaravati5 variants
SampleCompact secondary substations Amaravati · AMA-576 series
- Transformer rating
- 250 kVA to 1600 kVA (see variants)
- Primary voltage
- 22 kV
- Secondary voltage
- 0.433 kV
- HV equipment
- Ring main unit
- Transformer type
- Cast resin dry
Lead time 6-8 weeks · Warranty 18 months · MOQ 10 nos
Transformer monitoring (online DGA, bushing monitors)Coromandel4 variants
SampleTransformer monitoring (online DGA, bushing monitors) Coromandel · COR-9F4 series
- Gases monitored
- Single gas (H2) to 9 gases (see variants)
- Gases measured
- H2, CO
- Technology
- Photoacoustic
- Measurement interval
- 24 hours
- Accuracy
- +/- 5%
Lead time 8-10 weeks · Warranty 36 months with AMC · MOQ 1 nos
Shunt & series reactorsAjantajyoti5 variants
SampleShunt & series reactors Ajantajyoti · AJA-2B3 series
- Rating
- 25 MVAr to 200 MVAr (see variants)
- System voltage
- 132 kV
- Type
- Shunt
- Construction
- Air-core dry
- Phases
- Single
Lead time 40-50 weeks · Warranty 24 months from commissioning · MOQ 5 nos
Mobile substationsKutchwatt4 variants
Kutchwatt · KUT-031 series
- Transformer rating
- 20 MVA to 63 MVA (see variants)
- Primary voltage
- 220 kV
- Secondary voltage
- 11 kV
- Chassis
- Skid
- Primary switchgear
- GIS bay
Lead time 30-40 weeks · Warranty 36 months · MOQ 2 nos
Earthing & auxiliary transformersAjantajyoti3 variants
SampleEarthing & auxiliary transformers Ajantajyoti · AJA-C08 series
- Rating
- 315 kVA to 1000 kVA (see variants)
- Type
- Station service
- Primary voltage
- 33 kV
- Secondary voltage
- 0.433 kV
- Short-time rating
- 30 s
Lead time 8-10 weeks · Warranty 24 months · MOQ 2 nos
Dry-type transformersTaxilaurja5 variants
SampleDry-type transformers Taxilaurja · TAX-0E5 series
- Rating
- 100 kVA to 1600 kVA (see variants)
- Voltage ratio
- 33/0.433 kV
- Technology
- VPI
- Insulation class
- Class H
- Cooling
- AN/AF
Lead time 8-10 weeks · Warranty 36 months · MOQ 1 nos