Live-line & hot-line washingKaveriohm4 variants
SampleServiceLive-line & hot-line washing Kaveriohm · KAV-347 series
- Voltage level
- 66 kV to 400 kV (see variants)
- Method
- Dry ice blasting
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per km of line
- Frequency
- Pre- and post-monsoon
Lead time Permit based scheduling · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingGarudatron6 variants
SampleServiceLive-line & hot-line washing Garudatron · GAR-E72 series
- Voltage level
- 11 kV to 400 kV (see variants)
- Method
- Drone washing
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per bay
- Frequency
- Pre-monsoon
Lead time Mobilisation in 5-7 days · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingVidarbha3 variants
SampleServiceLive-line & hot-line washing Vidarbha · VID-345 series
- Voltage level
- 33 kV to 132 kV (see variants)
- Method
- Pressurised water jet
- Resistivity of water
- Demineralised water
- Scope
- Per km of line
- Frequency
- Pre- and post-monsoon
Lead time Mobilisation in 5-7 days · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingTrishulmark5 variants
SampleServiceLive-line & hot-line washing Trishulmark · TRI-344 series
- Voltage level
- 33 kV to 400 kV (see variants)
- Method
- Drone washing
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per tower
- Frequency
- Pre-monsoon
Lead time Permit based scheduling · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingShaktitek3 variants
SampleServiceLive-line & hot-line washing Shaktitek · SHA-AF7 series
- Voltage level
- 11 kV to 66 kV (see variants)
- Method
- Pressurised water jet
- Resistivity of water
- Demineralised water
- Scope
- Per km of line
- Frequency
- Pre-monsoon
Lead time Permit based scheduling · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingTrishulcore5 variants
SampleServiceLive-line & hot-line washing Trishulcore · TRI-E76 series
- Voltage level
- 11 kV to 220 kV (see variants)
- Method
- Dry ice blasting
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per bay
- Frequency
- Quarterly in coastal areas
Lead time Permit based scheduling · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingDoaba3 variants
SampleServiceLive-line & hot-line washing Doaba · DOA-3C1 series
- Voltage level
- 33 kV to 132 kV (see variants)
- Method
- Dry ice blasting
- Resistivity of water
- Demineralised water
- Scope
- Per km of line
- Frequency
- Pre- and post-monsoon
Lead time Mobilisation in 5-7 days · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingGarudatron6 variants
SampleServiceLive-line & hot-line washing Garudatron · GAR-344 series
- Voltage level
- 11 kV to 400 kV (see variants)
- Method
- Robotic cleaning
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per tower
- Frequency
- Pre-monsoon
Lead time Permit based scheduling · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingKrishna6 variants
SampleServiceLive-line & hot-line washing Krishna · KRI-E78 series
- Voltage level
- 11 kV to 400 kV (see variants)
- Method
- Pressurised water jet
- Resistivity of water
- Demineralised water
- Scope
- Per tower
- Frequency
- Quarterly in coastal areas
Lead time Permit based scheduling · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingGuptaphase5 variants
SampleServiceLive-line & hot-line washing Guptaphase · GUP-E75 series
- Voltage level
- 11 kV to 220 kV (see variants)
- Method
- Robotic cleaning
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per km of line
- Frequency
- Pre-monsoon
Lead time Mobilisation in 5-7 days · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingMagadh6 variants
SampleServiceLive-line & hot-line washing Magadh · MAG-343 series
- Voltage level
- 11 kV to 400 kV (see variants)
- Method
- Robotic cleaning
- Resistivity of water
- Demineralised water
- Scope
- Per tower
- Frequency
- Quarterly in coastal areas
Lead time Mobilisation in 5-7 days · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingMahanadi6 variants
SampleServiceLive-line & hot-line washing Mahanadi · MAH-3C1 series
- Voltage level
- 11 kV to 400 kV (see variants)
- Method
- Dry ice blasting
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per bay
- Frequency
- Pre-monsoon
Lead time Mobilisation in 5-7 days · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingKutch4 variants
SampleServiceLive-line & hot-line washing Kutch · KUT-3C4 series
- Voltage level
- 11 kV to 132 kV (see variants)
- Method
- Robotic cleaning
- Resistivity of water
- Demineralised water
- Scope
- Per km of line
- Frequency
- Pre- and post-monsoon
Lead time Permit based scheduling · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingMahanadiparam4 variants
SampleServiceLive-line & hot-line washing Mahanadiparam · MAH-E79 series
- Voltage level
- 11 kV to 132 kV (see variants)
- Method
- Drone washing
- Resistivity of water
- Demineralised water
- Scope
- Per km of line
- Frequency
- Pre- and post-monsoon
Lead time Mobilisation in 5-7 days · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingMaduraisurya4 variants
SampleServiceLive-line & hot-line washing Maduraisurya · MAD-341 series
- Voltage level
- 66 kV to 400 kV (see variants)
- Method
- Pressurised water jet
- Resistivity of water
- Demineralised water
- Scope
- Per tower
- Frequency
- Pre-monsoon
Lead time Mobilisation in 5-7 days · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingMaduraisurya4 variants
SampleServiceLive-line & hot-line washing Maduraisurya · MAD-3C2 series
- Voltage level
- 33 kV to 220 kV (see variants)
- Method
- Drone washing
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per tower
- Frequency
- Quarterly in coastal areas
Lead time Permit based scheduling · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingSahyadriakshay6 variants
SampleServiceLive-line & hot-line washing Sahyadriakshay · SAH-3C2 series
- Voltage level
- 11 kV to 400 kV (see variants)
- Method
- Dry ice blasting
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per km of line
- Frequency
- Quarterly in coastal areas
Lead time Mobilisation in 5-7 days · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingMagadh5 variants
SampleServiceLive-line & hot-line washing Magadh · MAG-E74 series
- Voltage level
- 33 kV to 400 kV (see variants)
- Method
- Robotic cleaning
- Resistivity of water
- Demineralised water
- Scope
- Per tower
- Frequency
- Quarterly in coastal areas
Lead time Mobilisation in 5-7 days · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingPrakashsys6 variants
SampleServiceLive-line & hot-line washing Prakashsys · PRA-E74 series
- Voltage level
- 11 kV to 400 kV (see variants)
- Method
- Pressurised water jet
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per km of line
- Frequency
- Pre-monsoon
Lead time Permit based scheduling · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingChambal3 variants
SampleServiceLive-line & hot-line washing Chambal · CHA-3C5 series
- Voltage level
- 132 kV to 400 kV (see variants)
- Method
- Robotic cleaning
- Resistivity of water
- Demineralised water
- Scope
- Per tower
- Frequency
- Pre-monsoon
Lead time Mobilisation in 5-7 days · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingMahanadiparam4 variants
SampleServiceLive-line & hot-line washing Mahanadiparam · MAH-E77 series
- Voltage level
- 33 kV to 220 kV (see variants)
- Method
- Pressurised water jet
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per km of line
- Frequency
- Quarterly in coastal areas
Lead time Permit based scheduling · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingSahyadriakshay5 variants
SampleServiceLive-line & hot-line washing Sahyadriakshay · SAH-AF2 series
- Voltage level
- 11 kV to 220 kV (see variants)
- Method
- Dry ice blasting
- Resistivity of water
- Demineralised water
- Scope
- Per tower
- Frequency
- Quarterly in coastal areas
Lead time Mobilisation in 5-7 days · Warranty Rewash if flashover within 30 days · MOQ 1 job
Live-line & hot-line washingTungabhadra5 variants
SampleServiceLive-line & hot-line washing Tungabhadra · TUN-E78 series
- Voltage level
- 33 kV to 400 kV (see variants)
- Method
- Dry ice blasting
- Resistivity of water
- Demineralised water
- Scope
- Per km of line
- Frequency
- Quarterly in coastal areas
Lead time Permit based scheduling · Warranty As per contract · MOQ 1 job
Live-line & hot-line washingDoaba5 variants
SampleServiceLive-line & hot-line washing Doaba · DOA-AF8 series
- Voltage level
- 11 kV to 220 kV (see variants)
- Method
- Dry ice blasting
- Resistivity of water
- Above 5000 ohm-cm
- Scope
- Per tower
- Frequency
- Pre-monsoon
Lead time Mobilisation in 5-7 days · Warranty As per contract · MOQ 1 job