Environment & emission control

Air-pollution control and environmental monitoring.

Companies offering this · 13

Listings (216)

Prices are shown to verified buyers. Register your company to see them and request quotes.

Semi-dry FGD with spray dryer, Smart series

SampleFlue-gas desulphurisation (FGD)

Kamrup · KAM-059 series

Boiler size
60 MW to 500 MW (see variants)
Technology
Dry sorbent
SO2 removal efficiency
95%
Inlet SO2
Up to 1500 mg/Nm3
Absorber material
Alloy lined

Lead time 24-36 weeks · Warranty 24 months performance guarantee · MOQ 1 set

Price for verified buyers

by Kamrup Emission Systems (Sample) · invoiced by BARREL

Request quote

Mahanadi · MAH-2A5 series

Gas flow rate
25000 Am3/h to 1000000 Am3/h (see variants)
Outlet emission
Below 50 mg/Nm3
Inlet temperature
Up to 180 deg C
Filter media
Polyester
Cleaning
Pulse jet

Lead time 20-28 weeks · Warranty 24 months on mechanical parts · MOQ 10 set

Price for verified buyers

by Mahanadi Environmental Systems (Sample) · invoiced by BARREL

Request quote

Coorg · COO-D01 series

Insertion loss
20 dB to 40 dB (see variants)
Equipment served
Compressor
Panel construction
GI perforated with rockwool
Infill
Rockwool 100 mm
Sheet thickness
1.6 mm

Lead time 3-4 weeks · Warranty 24 months against corrosion · MOQ 5 nos

Price for verified buyers

by Coorg Enviro Engineers (Sample) · invoiced by BARREL

Request quote

Deccanvolt · DEC-2A8 series

Gas flow rate
100000 Am3/h to 500000 Am3/h (see variants)
Outlet emission
Below 30 mg/Nm3
Inlet temperature
Up to 250 deg C
Filter media
PPS felt
Cleaning
Pulse jet

Lead time 20-28 weeks · Warranty 12 months from commissioning · MOQ 1 set

Price for verified buyers

by Deccanvolt Environmental Systems (Sample) · invoiced by BARREL

Request quote

Fly ash bricks, Ultra 7 series

SampleAsh utilisation

Munnarspark · MUN-397 series

Fly ash fineness (Blaine)
250 sq m/kg to 400 sq m/kg (see variants)
Source
Pond ash
Grade
Siliceous Grade 1
Loss on ignition
Below 2%
Moisture
Below 1%

Lead time 1-2 weeks · Warranty Test certificate per lot · MOQ 1 MT

Price for verified buyers

by Munnarspark Emission Systems (Sample) · invoiced by BARREL

Request quote

PM2.5 and PM10 analyser, Xtra 9 series

SampleCEMS & ambient air monitoring

Coorg · COO-909 series

Parameters monitored
PM only to Full CEMS 8 parameters (see variants)
Measurement method
Extractive hot-wet
Particulate sensor
Beta attenuation
Gas analyser
Chemiluminescence
Data logging
4-20 mA

Lead time 10-14 weeks · Warranty 24 months on analysers · MOQ 1 set

Price on quote

by Coorg Enviro Engineers (Sample) · invoiced by BARREL

Request quote

Urea dosing and storage unit, Volt series

SampleSCR / SNCR NOx control

Munnarspark · MUN-9A7 series

Flue gas flow
20000 Nm3/h to 1000000 Nm3/h (see variants)
Technology
Hybrid
NOx removal efficiency
40%
Reagent
Urea solution 40%
Catalyst
Honeycomb V2O5-WO3/TiO2

Lead time 30-44 weeks · Warranty 24000 operating hours on catalyst · MOQ 1 set

Price on quote

by Munnarspark Emission Systems (Sample) · invoiced by BARREL

Request quote

Saurashtra · SAU-595 series

Gas flow rate
25000 Am3/h to 1000000 Am3/h (see variants)
Outlet emission
Below 30 mg/Nm3
Inlet temperature
Up to 250 deg C
Filter media
Polyester
Cleaning
Reverse air

Lead time 12-16 weeks · Warranty 12 months from commissioning · MOQ 2 set

Price on quote

by Saurashtra Emission Systems (Sample) · invoiced by BARREL

Request quote

Pulse-jet bag filter, Eco 6 series

SampleESP & bag filters

Akshaymark · AKS-458 series

Gas flow rate
25000 Am3/h to 100000 Am3/h (see variants)
Outlet emission
Below 30 mg/Nm3
Inlet temperature
Up to 180 deg C
Filter media
PPS felt
Cleaning
Pulse jet

Lead time 12-16 weeks · Warranty 24 months on mechanical parts · MOQ 1 set

Price for verified buyers

by Akshaymark Emission Systems (Sample) · invoiced by BARREL

Request quote

Wet limestone FGD system, Pro series

SampleFlue-gas desulphurisation (FGD)

Saurashtra · SAU-772 series

Boiler size
25 MW to 500 MW (see variants)
Technology
Dry sorbent
SO2 removal efficiency
90%
Inlet SO2
Up to 1500 mg/Nm3
Absorber material
Rubber lined carbon steel

Lead time 24-36 weeks · Warranty 12 months from commissioning · MOQ 10 set

Price for verified buyers

by Saurashtra Emission Systems (Sample) · invoiced by BARREL

Request quote

Reverse-air bag filter, Pro series

SampleESP & bag filters

Saurashtra · SAU-8F7 series

Gas flow rate
10000 Am3/h to 50000 Am3/h (see variants)
Outlet emission
Below 30 mg/Nm3
Inlet temperature
Up to 250 deg C
Filter media
PPS felt
Cleaning
Reverse air

Lead time 20-28 weeks · Warranty 24 months on mechanical parts · MOQ 10 set

Price for verified buyers

by Saurashtra Emission Systems (Sample) · invoiced by BARREL

Request quote

Ambient air quality monitoring station, Flex series

SampleCEMS & ambient air monitoring

Kamrup · KAM-6D8 series

Parameters monitored
PM only to Full CEMS 8 parameters (see variants)
Measurement method
Extractive hot-wet
Particulate sensor
Beta attenuation
Gas analyser
NDIR
Data logging
4-20 mA

Lead time 6-8 weeks · Warranty 24 months on analysers · MOQ 2 set

Price for verified buyers

by Kamrup Emission Systems (Sample) · invoiced by BARREL

Request quote

Hybrid ESP-bag filter, Pro series

SampleESP & bag filters

Mahanadi · MAH-F06 series

Gas flow rate
25000 Am3/h to 1000000 Am3/h (see variants)
Outlet emission
Below 30 mg/Nm3
Inlet temperature
Up to 180 deg C
Filter media
Polyester
Cleaning
Reverse air

Lead time 12-16 weeks · Warranty 12 months from commissioning · MOQ 2 set

Price on quote

by Mahanadi Environmental Systems (Sample) · invoiced by BARREL

Request quote

Semi-dry FGD with spray dryer, Pro 3 series

SampleFlue-gas desulphurisation (FGD)

Deccanvolt · DEC-052 series

Boiler size
210 MW to 500 MW (see variants)
Technology
Dry sorbent
SO2 removal efficiency
95%
Inlet SO2
Up to 1500 mg/Nm3
Absorber material
Rubber lined carbon steel

Lead time 24-36 weeks · Warranty 24 months performance guarantee · MOQ 10 set

Price on quote

by Deccanvolt Environmental Systems (Sample) · invoiced by BARREL

Request quote

SNCR urea injection system, Max series

SampleSCR / SNCR NOx control

Amaravatitej · AMA-328 series

Flue gas flow
100000 Nm3/h to 1000000 Nm3/h (see variants)
Technology
Hybrid
NOx removal efficiency
90%
Reagent
Aqueous ammonia
Catalyst
Plate type

Lead time 30-44 weeks · Warranty 24000 operating hours on catalyst · MOQ 1 set

Price for verified buyers

by Amaravatitej Emission Systems (Sample) · invoiced by BARREL

Request quote

PM2.5 and PM10 analyser, Max 6 series

SampleCEMS & ambient air monitoring

Saurashtra · SAU-905 series

Parameters monitored
PM + SO2 + NOx + O2 to Full CEMS 8 parameters (see variants)
Measurement method
Dilution extractive
Particulate sensor
Light scattering
Gas analyser
Chemiluminescence
Data logging
4-20 mA

Lead time 6-8 weeks · Warranty 24 months on analysers · MOQ 10 set

Price for verified buyers

by Saurashtra Enviro Engineers (Sample) · invoiced by BARREL

Request quote