Bus post insulators & clampsPrithvimax6 variants
SampleBus post insulators & clamps Prithvimax · PRI-D82 series
- System voltage
- 12 kV to 420 kV (see variants)
- Type
- Pillar insulator
- Cantilever strength
- 8 kN
- Creepage
- 31 mm/kV
- Material
- Silicone composite
Lead time 6-8 weeks · Warranty 36 months · MOQ 1 nos
Isolators & earth switchesCoromandelphase6 variants
SampleIsolators & earth switches Coromandelphase · COR-0A5 series
- System voltage
- 12 kV to 420 kV (see variants)
- Rated current
- 4000 A
- Type
- Double break
- Earth switch
- Without
- Short-time current
- 25 kA
Lead time 6-8 weeks · Warranty 30 months from supply · MOQ 1 nos
Neutral grounding resistorsJhelumtesla5 variants
SampleNeutral grounding resistors Jhelumtesla · JHE-C14 series
- Rated current
- 100 A to 1500 A (see variants)
- System voltage
- 6.6 kV
- Resistance
- 20 ohm
- Time rating
- 10 s
- Element
- Liquid electrolyte
Lead time 8-10 weeks · Warranty 18 months · MOQ 2 nos
Surge arresters (station class)Prithvicore3 variants
SampleSurge arresters (station class) Prithvicore · PRI-CD5 series
- System voltage
- 36 kV to 145 kV (see variants)
- Rated voltage
- 120 kV
- Nominal discharge current
- 20 kA
- Line discharge class
- Class 5
- Housing
- Polymer
Lead time 8-10 weeks · Warranty 24 months · MOQ 10 nos
Bus post insulators & clampsSabarmati3 variants
SampleBus post insulators & clamps Sabarmati · SAB-3E7 series
- System voltage
- 36 kV to 145 kV (see variants)
- Type
- Solid core post
- Cantilever strength
- 6 kN
- Creepage
- 25 mm/kV
- Material
- Porcelain
Lead time 3-5 weeks · Warranty 24 months · MOQ 2 nos
Isolators & earth switchesKanchi6 variants
SampleIsolators & earth switches Kanchi · KAN-C73 series
- System voltage
- 12 kV to 420 kV (see variants)
- Rated current
- 4000 A
- Type
- Vertical break
- Earth switch
- With 2 earth switches
- Short-time current
- 50 kA
Lead time 10-14 weeks · Warranty 24 months · MOQ 1 nos
SF6-free (vacuum, clean-air) HV breakersKanchi3 variants
SampleSF6-free (vacuum, clean-air) HV breakers Kanchi · KAN-3E3 series
- System voltage
- 36 kV to 145 kV (see variants)
- Insulation medium
- Dry air
- Interrupter
- Vacuum
- Rated current
- 3150 A
- Breaking current
- 40 kA
Lead time 16-20 weeks · Warranty 36 months · MOQ 1 nos
Surge arresters (station class)Sahyadritamra4 variants
SampleSurge arresters (station class) Sahyadritamra · SAH-CD8 series
- System voltage
- 36 kV to 245 kV (see variants)
- Rated voltage
- 330 kV
- Nominal discharge current
- 10 kA
- Line discharge class
- Class 4
- Housing
- Porcelain
Lead time 3-5 weeks · Warranty 24 months · MOQ 10 nos
SF6 circuit breakersPrithvimax6 variants
SampleSF6 circuit breakers Prithvimax · PRI-282 series
- System voltage
- 36 kV to 800 kV (see variants)
- Rated current
- 4000 A
- Breaking current
- 50 kA
- Operating mechanism
- Spring-spring
- Operation
- 3-pole
Lead time 12-16 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Hybrid & dead-tank switchgearMarwarsudarshan3 variants
SampleHybrid & dead-tank switchgear Marwarsudarshan · MAR-FD4 series
- System voltage
- 145 kV to 420 kV (see variants)
- Concept
- Compact
- Rated current
- 4000 A
- Breaking current
- 40 kA
- Gas
- SF6
Lead time 28-36 weeks · Warranty 36 months · MOQ 1 nos
Bus post insulators & clampsTungabhadra4 variants
SampleBus post insulators & clamps Tungabhadra · TUN-CD8 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Type
- Composite post
- Cantilever strength
- 12.5 kN
- Creepage
- 31 mm/kV
- Material
- Silicone composite
Lead time 6-8 weeks · Warranty 24 months · MOQ 1 nos
Bus post insulators & clampsSahyadri6 variants
SampleBus post insulators & clamps Sahyadri · SAH-D84 series
- System voltage
- 12 kV to 420 kV (see variants)
- Type
- Composite post
- Cantilever strength
- 12.5 kN
- Creepage
- 31 mm/kV
- Material
- Silicone composite
Lead time 3-5 weeks · Warranty 24 months · MOQ 2 nos
Hybrid & dead-tank switchgearAmaravatianant4 variants
SampleHybrid & dead-tank switchgear Amaravatianant · AMA-8F4 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Concept
- Hybrid
- Rated current
- 4000 A
- Breaking current
- 31.5 kA
- Gas
- SF6-free
Lead time 16-24 weeks · Warranty 24 months · MOQ 1 nos
Gas-insulated switchgear (GIS)Hoysalasudarshan4 variants
SampleGas-insulated switchgear (GIS) Hoysalasudarshan · HOY-0F1 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Rated current
- 3150 A
- Short-circuit current
- 50 kA
- Configuration
- Single bus
- Enclosure
- Steel
Lead time 20-28 weeks · Warranty 36 months · MOQ 1 bay
Gas-insulated switchgear (GIS)Amaravatianant5 variants
SampleGas-insulated switchgear (GIS) Amaravatianant · AMA-7A8 series
- System voltage
- 36 kV to 420 kV (see variants)
- Rated current
- 2500 A
- Short-circuit current
- 40 kA
- Configuration
- Single bus
- Enclosure
- Aluminium alloy
Lead time 20-28 weeks · Warranty 24 months · MOQ 1 bay
Isolators & earth switchesRajatline5 variants
SampleIsolators & earth switches Rajatline · RAJ-B85 series
- System voltage
- 36 kV to 420 kV (see variants)
- Rated current
- 1250 A
- Type
- Vertical break
- Earth switch
- With 1 earth switch
- Short-time current
- 25 kA
Lead time 6-8 weeks · Warranty 30 months from supply · MOQ 5 nos
SF6-free (vacuum, clean-air) HV breakersVijaya3 variants
SampleSF6-free (vacuum, clean-air) HV breakers Vijaya · VIJ-528 series
- System voltage
- 72.5 kV to 170 kV (see variants)
- Insulation medium
- Fluoronitrile mix
- Interrupter
- Vacuum
- Rated current
- 3150 A
- Breaking current
- 31.5 kA
Lead time 16-20 weeks · Warranty 36 months · MOQ 1 nos
Surge arresters (station class)Prithvimax6 variants
SampleSurge arresters (station class) Prithvimax · PRI-CD3 series
- System voltage
- 12 kV to 420 kV (see variants)
- Rated voltage
- 30 kV
- Nominal discharge current
- 5 kA
- Line discharge class
- Class 2
- Housing
- Porcelain
Lead time 8-10 weeks · Warranty 24 months · MOQ 5 nos
Bus post insulators & clampsMarwarsudarshan6 variants
SampleBus post insulators & clamps Marwarsudarshan · MAR-CD5 series
- System voltage
- 12 kV to 420 kV (see variants)
- Type
- Composite post
- Cantilever strength
- 12.5 kN
- Creepage
- 25 mm/kV
- Material
- Porcelain
Lead time 3-5 weeks · Warranty 36 months · MOQ 10 nos
Tubular busbars & switchyard conductorsPrithvicore4 variants
SampleTubular busbars & switchyard conductors Prithvicore · PRI-D96 series
- Pipe size
- 50 mm OD to 150 mm OD (see variants)
- Material
- Copper
- Wall thickness
- 10 mm
- Current rating
- 2500 A
- Length available
- 10 m
Lead time 3-5 weeks · Warranty 12 months · MOQ 2 m
Tubular busbars & switchyard conductorsJhelum4 variants
SampleTubular busbars & switchyard conductors Jhelum · JHE-D93 series
- Pipe size
- 100 mm OD to 250 mm OD (see variants)
- Material
- Aluminium AA 6101 T6
- Wall thickness
- 8 mm
- Current rating
- 6300 A
- Length available
- 10 m
Lead time 3-5 weeks · Warranty 24 months · MOQ 1 m
Hybrid & dead-tank switchgearJhelumtesla4 variants
SampleHybrid & dead-tank switchgear Jhelumtesla · JHE-FD3 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Concept
- Hybrid
- Rated current
- 3150 A
- Breaking current
- 40 kA
- Gas
- SF6-free
Lead time 28-36 weeks · Warranty 24 months · MOQ 5 nos
Isolators & earth switchesSabarmati3 variants
SampleIsolators & earth switches Sabarmati · SAB-B82 series
- System voltage
- 12 kV to 72.5 kV (see variants)
- Rated current
- 4000 A
- Type
- Centre rotating
- Earth switch
- Without
- Short-time current
- 25 kA
Lead time 6-8 weeks · Warranty 30 months from supply · MOQ 1 nos
SF6 circuit breakersHoysalasudarshan4 variants
SampleSF6 circuit breakers Hoysalasudarshan · HOY-2E2 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Rated current
- 2000 A
- Breaking current
- 50 kA
- Operating mechanism
- Hydraulic spring
- Operation
- Single-pole
Lead time 24-30 weeks · Warranty 24 months from commissioning · MOQ 1 nos