SF6 insulated compact RMU, Max series

SampleRing main units (RMU)

Coromandelampere · COR-993 series

Configuration
2-way (LBS+LBS) to 5-way (3LBS+2VCB) (see variants)
Rated voltage
24 kV
Rated current - ring
630 A
Transformer feeder
200 A fuse-switch
Short-circuit rating
16 kA/3 s

Lead time 8-12 weeks · Warranty 12 months from commissioning · MOQ 1 nos

Price on quote

by Coromandelampere Switchboards (Sample) · invoiced by BARREL

Request quote

Hampitej · HAM-A48 series

Rating
100 A to 1600 A (see variants)
Panel type
MCC
System voltage
220 V DC
Short-circuit rating
25 kA/1 s
Form of separation
Form 4b

Lead time 3-4 weeks · Warranty 12 months from commissioning · MOQ 1 nos

Price for verified buyers

by Hampitej Switchboards (Sample) · invoiced by BARREL

Request quote

SF6 insulated compact RMU, Elite series

SampleRing main units (RMU)

Samarthmax · SAM-998 series

Configuration
2-way (LBS+LBS) to 4-way (3LBS+TF) (see variants)
Rated voltage
24 kV
Rated current - ring
400 A
Transformer feeder
200 A fuse-switch
Short-circuit rating
20 kA/3 s

Lead time 4-6 weeks · Warranty 24 months from supply · MOQ 2 nos

Price for verified buyers

by Samarthmax Switchboards (Sample) · invoiced by BARREL

Request quote

Lonavala · LON-5C4 series

Configuration
4-way (2LBS+LBS+VCB) to 5-way (3LBS+2VCB) (see variants)
Rated voltage
36 kV
Rated current - ring
400 A
Transformer feeder
200 A fuse-switch
Short-circuit rating
25 kA/3 s

Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 5 nos

Price for verified buyers

by Lonavala Panels (Sample) · invoiced by BARREL

Request quote

Star-delta starter panel, Xtra series

SampleContactors, overload relays & motor starters

Lohacore · LOH-8B5 series

Rating
115 A to 265 A (see variants)
Device type
Soft starter
Coil voltage
110 V AC
Utilisation category
AC-4
Motor rating at 415 V
132 kW

Lead time 3-4 weeks · Warranty 18 months from supply · MOQ 10 nos

Price for verified buyers

by Lohacore Switchgear (Sample) · invoiced by BARREL

Request quote

AC power contactor, Eco 2 series

SampleContactors, overload relays & motor starters

Vindhya · VIN-5B5 series

Rating
9 A to 65 A (see variants)
Device type
Overload relay
Coil voltage
110 V AC
Utilisation category
AC-4
Motor rating at 415 V
15 kW

Lead time 3-4 weeks · Warranty 18 months from supply · MOQ 10 nos

Price for verified buyers

by Vindhya Switchboards (Sample) · invoiced by BARREL

Request quote

Indoor MV switchgear panel with VCB, Elite 9 series

SampleMV metal-clad switchboards (11–33 kV)

Mysoreohm · MYS-B84 series

Rating
11 kV 630 A to 33 kV 2000 A (see variants)
Insulation
Solid insulated
Short-circuit rating
40 kA/3 s
Panel function
Capacitor bank feeder
Busbar
Double busbar

Lead time 8-10 weeks · Warranty 24 months from supply · MOQ 1 nos

Price for verified buyers

by Mysoreohm Panels (Sample) · invoiced by BARREL

Request quote

Air-insulated 11 kV switchboard, Eco 3 series

SampleMV metal-clad switchboards (11–33 kV)

Hampitej · HAM-6E1 series

Rating
11 kV 1250 A to 33 kV 1250 A (see variants)
Insulation
Air-insulated
Short-circuit rating
31.5 kA/3 s
Panel function
Bus coupler
Busbar
Double busbar

Lead time 8-10 weeks · Warranty 18 months from commissioning · MOQ 5 nos

Price for verified buyers

by Hampitej Switchboards (Sample) · invoiced by BARREL

Request quote

On-load changeover switch, Titan 3 series

SampleChangeover switches & ATS panels

Samarthmax · SAM-B46 series

Rating
125 A to 1000 A (see variants)
Type
ATS panel
Poles
4P
Rated voltage
415 V AC
Transfer device
Switch-disconnector

Lead time 4-6 weeks · Warranty 12 months from commissioning · MOQ 1 nos

Price for verified buyers

by Samarthmax Switchboards (Sample) · invoiced by BARREL

Request quote

Motorised ACB-based ATS panel, Duo series

SampleChangeover switches & ATS panels

Saurashtra · SAU-2B4 series

Rating
400 A to 1600 A (see variants)
Type
ATS panel
Poles
3P
Rated voltage
415 V AC
Transfer device
Interlocked MCCB

Lead time 1-2 weeks · Warranty 12 months from commissioning · MOQ 5 nos

Price for verified buyers

by Saurashtra Switchgear (Sample) · invoiced by BARREL

Request quote

Star-delta starter panel, Neo series

SampleContactors, overload relays & motor starters

Lohacore · LOH-8B2 series

Rating
65 A to 400 A (see variants)
Device type
DOL starter
Coil voltage
415 V AC
Utilisation category
AC-1
Motor rating at 415 V
55 kW

Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 1 nos

Price for verified buyers

by Lohacore Switchgear (Sample) · invoiced by BARREL

Request quote

Manual changeover switch, Eco 6 series

SampleChangeover switches & ATS panels

Lohacore · LOH-2B4 series

Rating
400 A to 2500 A (see variants)
Type
Manual changeover
Poles
3P
Rated voltage
415 V AC
Transfer device
Switch-disconnector

Lead time 1-2 weeks · Warranty 18 months from supply · MOQ 1 nos

Price for verified buyers

by Lohacore Switchgear (Sample) · invoiced by BARREL

Request quote

Electronic motor protection relay, Smart 4 series

SampleContactors, overload relays & motor starters

Nilgirisudarshan · NIL-FF4 series

Rating
32 A to 265 A (see variants)
Device type
Star-delta starter
Coil voltage
110 V AC
Utilisation category
AC-3
Motor rating at 415 V
55 kW

Lead time 3-4 weeks · Warranty 12 months from supply · MOQ 5 nos

Price for verified buyers

by Nilgirisudarshan Panels (Sample) · invoiced by BARREL

Request quote