SF6 circuit breakersJhelum3 variants
SampleSF6 circuit breakers Jhelum · JHE-EB4 series
- System voltage
- 72.5 kV to 245 kV (see variants)
- Rated current
- 3150 A
- Breaking current
- 40 kA
- Operating mechanism
- Spring-spring
- Operation
- Single-pole
Lead time 12-16 weeks · Warranty 30 months from supply · MOQ 5 nos
Neutral grounding resistorsHoysalasudarshan6 variants
SampleNeutral grounding resistors Hoysalasudarshan · HOY-6E3 series
- Rated current
- 50 A to 1500 A (see variants)
- System voltage
- 33 kV
- Resistance
- 20 ohm
- Time rating
- 60 s
- Element
- Cast iron
Lead time 4-6 weeks · Warranty 18 months · MOQ 2 nos
Neutral grounding resistorsSahyadri5 variants
SampleNeutral grounding resistors Sahyadri · SAH-6E6 series
- Rated current
- 100 A to 1500 A (see variants)
- System voltage
- 11 kV
- Resistance
- 100 ohm
- Time rating
- Continuous
- Element
- Liquid electrolyte
Lead time 8-10 weeks · Warranty 24 months · MOQ 1 nos
Bus post insulators & clampsSabarmati6 variants
SampleBus post insulators & clamps Sabarmati · SAB-3E1 series
- System voltage
- 12 kV to 420 kV (see variants)
- Type
- Solid core post
- Cantilever strength
- 12.5 kN
- Creepage
- 25 mm/kV
- Material
- Porcelain
Lead time 6-8 weeks · Warranty 24 months · MOQ 10 nos
Bus post insulators & clampsHoysalasudarshan4 variants
SampleBus post insulators & clamps Hoysalasudarshan · HOY-D77 series
- System voltage
- 12 kV to 145 kV (see variants)
- Type
- Composite post
- Cantilever strength
- 12.5 kN
- Creepage
- 25 mm/kV
- Material
- Silicone composite
Lead time 6-8 weeks · Warranty 24 months · MOQ 2 nos
Hybrid & dead-tank switchgearMarwarsudarshan4 variants
SampleHybrid & dead-tank switchgear Marwarsudarshan · MAR-FD2 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Concept
- Hybrid
- Rated current
- 3150 A
- Breaking current
- 40 kA
- Gas
- SF6-free
Lead time 16-24 weeks · Warranty 24 months · MOQ 1 nos
Surge arresters (station class)Jhelum3 variants
SampleSurge arresters (station class) Jhelum · JHE-EE5 series
- System voltage
- 145 kV to 420 kV (see variants)
- Rated voltage
- 192 kV
- Nominal discharge current
- 5 kA
- Line discharge class
- Class 3
- Housing
- Porcelain
Lead time 8-10 weeks · Warranty 24 months · MOQ 5 nos
Hybrid & dead-tank switchgearKanchi4 variants
SampleHybrid & dead-tank switchgear Kanchi · KAN-071 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Concept
- Compact
- Rated current
- 3150 A
- Breaking current
- 50 kA
- Gas
- SF6-free
Lead time 28-36 weeks · Warranty 36 months · MOQ 2 nos
SF6-free (vacuum, clean-air) HV breakersSahyadri3 variants
SampleSF6-free (vacuum, clean-air) HV breakers Sahyadri · SAH-2A1 series
- System voltage
- 145 kV to 245 kV (see variants)
- Insulation medium
- Clean air
- Interrupter
- Multi-break vacuum
- Rated current
- 1250 A
- Breaking current
- 31.5 kA
Lead time 16-20 weeks · Warranty 36 months · MOQ 10 nos
Surge arresters (station class)Jhelum6 variants
SampleSurge arresters (station class) Jhelum · JHE-EE7 series
- System voltage
- 12 kV to 420 kV (see variants)
- Rated voltage
- 330 kV
- Nominal discharge current
- 10 kA
- Line discharge class
- Class 3
- Housing
- Porcelain
Lead time 8-10 weeks · Warranty 36 months · MOQ 10 nos
Surge arresters (station class)Sahyadri3 variants
SampleSurge arresters (station class) Sahyadri · SAH-CD7 series
- System voltage
- 145 kV to 420 kV (see variants)
- Rated voltage
- 120 kV
- Nominal discharge current
- 20 kA
- Line discharge class
- Class 4
- Housing
- Porcelain
Lead time 8-10 weeks · Warranty 24 months · MOQ 10 nos
SF6-free (vacuum, clean-air) HV breakersSahyadritamra5 variants
SampleSF6-free (vacuum, clean-air) HV breakers Sahyadritamra · SAH-2A7 series
- System voltage
- 36 kV to 245 kV (see variants)
- Insulation medium
- Clean air
- Interrupter
- Vacuum
- Rated current
- 2000 A
- Breaking current
- 31.5 kA
Lead time 30-40 weeks · Warranty 24 months · MOQ 5 nos
Hybrid & dead-tank switchgearRajatline4 variants
SampleHybrid & dead-tank switchgear Rajatline · RAJ-CB1 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Concept
- Dead tank
- Rated current
- 4000 A
- Breaking current
- 50 kA
- Gas
- SF6-free
Lead time 28-36 weeks · Warranty 36 months · MOQ 1 nos
Isolators & earth switchesMewar3 variants
SampleIsolators & earth switches Mewar · MEW-735 series
- System voltage
- 145 kV to 420 kV (see variants)
- Rated current
- 3150 A
- Type
- Double break
- Earth switch
- Without
- Short-time current
- 50 kA
Lead time 6-8 weeks · Warranty 30 months from supply · MOQ 1 nos
Hybrid & dead-tank switchgearKonkanparam4 variants
SampleHybrid & dead-tank switchgear Konkanparam · KON-FD6 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Concept
- Dead tank
- Rated current
- 4000 A
- Breaking current
- 50 kA
- Gas
- SF6
Lead time 16-24 weeks · Warranty 36 months · MOQ 1 nos
Hybrid & dead-tank switchgearSahyadritamra3 variants
SampleHybrid & dead-tank switchgear Sahyadritamra · SAH-259 series
- System voltage
- 145 kV to 420 kV (see variants)
- Concept
- Hybrid
- Rated current
- 3150 A
- Breaking current
- 40 kA
- Gas
- SF6
Lead time 28-36 weeks · Warranty 36 months · MOQ 1 nos
SF6-free (vacuum, clean-air) HV breakersMalabarojas3 variants
SampleSF6-free (vacuum, clean-air) HV breakers Malabarojas · MAL-3E7 series
- System voltage
- 145 kV to 245 kV (see variants)
- Insulation medium
- Dry air
- Interrupter
- Multi-break vacuum
- Rated current
- 2000 A
- Breaking current
- 31.5 kA
Lead time 30-40 weeks · Warranty 36 months · MOQ 1 nos
Surge arresters (station class)Madurai4 variants
SampleSurge arresters (station class) Madurai · MAD-8C5 series
- System voltage
- 36 kV to 245 kV (see variants)
- Rated voltage
- 192 kV
- Nominal discharge current
- 20 kA
- Line discharge class
- Class 3
- Housing
- Porcelain
Lead time 3-5 weeks · Warranty 36 months · MOQ 1 nos
Hybrid & dead-tank switchgearTungabhadra4 variants
SampleHybrid & dead-tank switchgear Tungabhadra · TUN-CB5 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Concept
- Compact
- Rated current
- 4000 A
- Breaking current
- 40 kA
- Gas
- SF6
Lead time 16-24 weeks · Warranty 36 months · MOQ 2 nos
Gas-insulated switchgear (GIS)Jhelumtesla5 variants
SampleGas-insulated switchgear (GIS) Jhelumtesla · JHE-D34 series
- System voltage
- 36 kV to 420 kV (see variants)
- Rated current
- 4000 A
- Short-circuit current
- 31.5 kA
- Configuration
- Double bus
- Enclosure
- Aluminium alloy
Lead time 40-52 weeks · Warranty 24 months · MOQ 1 bay
Isolators & earth switchesJhelumtesla3 variants
SampleIsolators & earth switches Jhelumtesla · JHE-738 series
- System voltage
- 36 kV to 145 kV (see variants)
- Rated current
- 2000 A
- Type
- Centre rotating
- Earth switch
- With 1 earth switch
- Short-time current
- 25 kA
Lead time 10-14 weeks · Warranty 30 months from supply · MOQ 2 nos
Bus post insulators & clampsSahyadritamra4 variants
SampleBus post insulators & clamps Sahyadritamra · SAH-D87 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Type
- Solid core post
- Cantilever strength
- 8 kN
- Creepage
- 25 mm/kV
- Material
- Silicone composite
Lead time 6-8 weeks · Warranty 36 months · MOQ 1 nos
SF6-free (vacuum, clean-air) HV breakersSabarmati3 variants
SampleSF6-free (vacuum, clean-air) HV breakers Sabarmati · SAB-1E1 series
- System voltage
- 145 kV to 245 kV (see variants)
- Insulation medium
- Fluoronitrile mix
- Interrupter
- Vacuum
- Rated current
- 2000 A
- Breaking current
- 31.5 kA
Lead time 16-20 weeks · Warranty 36 months · MOQ 1 nos
Bus post insulators & clampsKanchi3 variants
SampleBus post insulators & clamps Kanchi · KAN-CD9 series
- System voltage
- 12 kV to 72.5 kV (see variants)
- Type
- Pillar insulator
- Cantilever strength
- 8 kN
- Creepage
- 31 mm/kV
- Material
- Porcelain
Lead time 3-5 weeks · Warranty 24 months · MOQ 10 nos