Isolators & earth switchesSahyadritamra4 variants
SampleIsolators & earth switches Sahyadritamra · SAH-B89 series
- System voltage
- 72.5 kV to 420 kV (see variants)
- Rated current
- 1250 A
- Type
- Double break
- Earth switch
- With 2 earth switches
- Short-time current
- 25 kA
Lead time 6-8 weeks · Warranty 24 months · MOQ 1 nos
Tubular busbars & switchyard conductorsRajatline3 variants
SampleTubular busbars & switchyard conductors Rajatline · RAJ-098 series
- Pipe size
- 50 mm OD to 100 mm OD (see variants)
- Material
- Copper
- Wall thickness
- 10 mm
- Current rating
- 2500 A
- Length available
- 6 m
Lead time 3-5 weeks · Warranty 12 months · MOQ 1 m
Gas-insulated switchgear (GIS)Vijaya5 variants
SampleGas-insulated switchgear (GIS) Vijaya · VIJ-981 series
- System voltage
- 36 kV to 420 kV (see variants)
- Rated current
- 3150 A
- Short-circuit current
- 31.5 kA
- Configuration
- Single bus
- Enclosure
- Steel
Lead time 40-52 weeks · Warranty 24 months · MOQ 1 bay
Surge arresters (station class)Rajatline6 variants
SampleSurge arresters (station class) Rajatline · RAJ-FF9 series
- System voltage
- 12 kV to 420 kV (see variants)
- Rated voltage
- 120 kV
- Nominal discharge current
- 5 kA
- Line discharge class
- Class 4
- Housing
- Porcelain
Lead time 8-10 weeks · Warranty 36 months · MOQ 10 nos
Mobile substationsMauryajal3 variants
Mauryajal · MAU-342 series
- Transformer rating
- 10 MVA to 31.5 MVA (see variants)
- Primary voltage
- 220 kV
- Secondary voltage
- 11 kV
- Chassis
- Low-bed trailer
- Primary switchgear
- GIS bay
Lead time 30-40 weeks · Warranty 24 months · MOQ 1 nos
ACSR, AAAC & HTLS conductorsBrahmaputrasamarth6 variants
SampleACSR, AAAC & HTLS conductors Brahmaputrasamarth · BRA-D46 series
- Conductor
- Rabbit to Zebra (see variants)
- Type
- AAAC
- Stranding
- 30/7
- Aluminium area
- 100 mm2
- Overall diameter
- 31.8 mm
Lead time 6-8 weeks · Warranty 12 months · MOQ 10 km
Mobile substationsKakatiya4 variants
Kakatiya · KAK-7D4 series
- Transformer rating
- 10 MVA to 50 MVA (see variants)
- Primary voltage
- 132 kV
- Secondary voltage
- 33 kV
- Chassis
- Skid
- Primary switchgear
- AIS disconnector and breaker
Lead time 16-24 weeks · Warranty 36 months · MOQ 1 nos
Section insulators & neutral sectionsSabarmati3 variants
SampleSection insulators & neutral sections Sabarmati · SAB-C92 series
- Type
- Standard section insulator to Insulated overlap (see variants)
- Voltage
- 25 kV AC
- Material
- Polymer
- Length
- 15 m
- Rated current
- 400 A
Lead time 8-10 weeks · Warranty 24 months · MOQ 1 nos
SF6 circuit breakersMalabarojas6 variants
SampleSF6 circuit breakers Malabarojas · MAL-CD4 series
- System voltage
- 36 kV to 800 kV (see variants)
- Rated current
- 3150 A
- Breaking current
- 40 kA
- Operating mechanism
- Spring-spring
- Operation
- 3-pole
Lead time 12-16 weeks · Warranty 24 months from commissioning · MOQ 2 nos
Tower parts, bolts & nutsCoromandelakash3 variants
SampleTower parts, bolts & nuts Coromandelakash · COR-D27 series
- Bolt size
- M16 to M24 (see variants)
- Strength class
- 5.6
- Material
- Mild steel
- Galvanising
- Hot-dip, 43 micron
- Thread
- Metric coarse
Lead time 2-4 weeks · Warranty 12 months · MOQ 1 MT
Furnace & rectifier transformersTamratek6 variants
SampleFurnace & rectifier transformers Tamratek · TAM-693 series
- Rating
- 5 MVA to 100 MVA (see variants)
- Primary voltage
- 11 kV
- Secondary voltage
- Up to 400 V DC rectified
- Application
- SAF
- Cooling
- ONAN/ONAF
Lead time 16-20 weeks · Warranty 36 months from supply · MOQ 10 nos
Section insulators & neutral sectionsDhruvline5 variants
SampleSection insulators & neutral sections Dhruvline · DHR-2A2 series
- Type
- Standard section insulator to Auto-passing neutral (see variants)
- Voltage
- 25 kV AC
- Material
- Epoxy glass
- Length
- 20 m
- Rated current
- 600 A
Lead time 8-10 weeks · Warranty 24 months · MOQ 5 nos
SF6 circuit breakersMadurai4 variants
SampleSF6 circuit breakers Madurai · MAD-CD9 series
- System voltage
- 145 kV to 800 kV (see variants)
- Rated current
- 1250 A
- Breaking current
- 50 kA
- Operating mechanism
- Hydraulic spring
- Operation
- Single-pole
Lead time 24-30 weeks · Warranty 30 months from supply · MOQ 1 nos
Tubular busbars & switchyard conductorsAmaravatianant5 variants
SampleTubular busbars & switchyard conductors Amaravatianant · AMA-091 series
- Pipe size
- 63 mm OD to 250 mm OD (see variants)
- Material
- Copper
- Wall thickness
- 10 mm
- Current rating
- 1250 A
- Length available
- 6 m
Lead time 6-8 weeks · Warranty 12 months · MOQ 1 m
Section insulators & neutral sectionsKonarkkiran4 variants
SampleSection insulators & neutral sections Konarkkiran · KON-358 series
- Type
- Neutral section to Auto-passing neutral (see variants)
- Voltage
- 25 kV AC
- Material
- Epoxy glass
- Length
- 20 m
- Rated current
- 600 A
Lead time 8-10 weeks · Warranty 24 months · MOQ 10 nos
Tubular busbars & switchyard conductorsSahyadri5 variants
SampleTubular busbars & switchyard conductors Sahyadri · SAH-D95 series
- Pipe size
- 50 mm OD to 200 mm OD (see variants)
- Material
- Copper
- Wall thickness
- 10 mm
- Current rating
- 2500 A
- Length available
- 6 m
Lead time 3-5 weeks · Warranty 24 months · MOQ 10 m
Auxiliary, trip & timer relaysLumentron5 variants
SampleAuxiliary, trip & timer relays Lumentron · LUM-025 series
- Coil voltage
- 24 V DC to 230 V AC (see variants)
- Relay type
- Lockout 86
- Contacts
- 8NO
- Contact rating
- 16 A
- Operate time
- < 10 ms
Lead time 1-2 weeks · Warranty 24 months · MOQ 5 nos
Traction substations & transformersUrjaline3 variants
SampleTraction substations & transformers Urjaline · URJ-916 series
- Rating
- 21.6 MVA to 50 MVA (see variants)
- Primary voltage
- 220 kV
- Secondary voltage
- 27.5 kV
- Connection
- V-V
- Cooling
- ONAN/ONAF
Lead time 16-20 weeks · Warranty 24 months from commissioning · MOQ 1 nos
Compact secondary substationsCoorgswarna3 variants
SampleCompact secondary substations Coorgswarna · COO-116 series
- Transformer rating
- 250 kVA to 630 kVA (see variants)
- Primary voltage
- 11 kV
- Secondary voltage
- 0.433 kV
- HV equipment
- VCB panel
- Transformer type
- Oil-immersed
Lead time 10-14 weeks · Warranty 24 months · MOQ 1 nos
Dry-type transformersKonark3 variants
SampleDry-type transformers Konark · KON-F97 series
- Rating
- 100 kVA to 500 kVA (see variants)
- Voltage ratio
- 11/0.433 kV
- Technology
- VPI
- Insulation class
- Class H
- Cooling
- AN
Lead time 4-6 weeks · Warranty 24 months · MOQ 1 nos
Surge arresters (station class)Vijaya3 variants
SampleSurge arresters (station class) Vijaya · VIJ-721 series
- System voltage
- 36 kV to 145 kV (see variants)
- Rated voltage
- 330 kV
- Nominal discharge current
- 10 kA
- Line discharge class
- Class 2
- Housing
- Porcelain
Lead time 3-5 weeks · Warranty 24 months · MOQ 2 nos
Isolators & earth switchesMarwarsudarshan4 variants
SampleIsolators & earth switches Marwarsudarshan · MAR-1C9 series
- System voltage
- 12 kV to 145 kV (see variants)
- Rated current
- 1250 A
- Type
- Centre rotating
- Earth switch
- With 2 earth switches
- Short-time current
- 25 kA
Lead time 6-8 weeks · Warranty 30 months from supply · MOQ 1 nos
Compact secondary substationsThanjavurprakash5 variants
SampleCompact secondary substations Thanjavurprakash · THA-6C1 series
- Transformer rating
- 100 kVA to 1000 kVA (see variants)
- Primary voltage
- 33 kV
- Secondary voltage
- 0.433 kV
- HV equipment
- Fuse switch
- Transformer type
- Cast resin dry
Lead time 6-8 weeks · Warranty 24 months · MOQ 1 nos
Battery chargers & DC systemsShivalik5 variants
SampleBattery chargers & DC systems Shivalik · SHI-657 series
- Rating
- 10 A to 200 A (see variants)
- Output voltage
- 48 V
- Input
- 230 V 1-ph
- Topology
- SMPS
- Voltage regulation
- +/- 1%
Lead time 3-5 weeks · Warranty 36 months · MOQ 5 nos