Third-party inspection (TPI)

Sub-category C51-01 of Testing, inspection & certification.

Companies offering this · 20

Listings (34)

Prices are shown to verified buyers. Register your company to see them and request quotes.

Shaktimark · SHA-094 series

Inspection effort
20 man-days to 100 man-days (see variants)
Equipment inspected
PV modules and inverters
Inspection stage
Raw material
Standards used
Per approved QAP
Inspector qualification
Level II NDT certified

Lead time Inspector assigned in 48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price on quote

by Shaktimark Projects (Sample) · invoiced by BARREL

Request quote

Solar module and inverter inspection, Flex series

SampleServiceThird-party inspection (TPI)

Malwavolt · MAL-AE3 series

Inspection effort
1 man-day to 100 man-days (see variants)
Equipment inspected
Towers and structures
Inspection stage
In-process
Standards used
Per client specification
Inspector qualification
B.E. Electrical with 8 years experience

Lead time Report in 24-48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price for verified buyers

by Malwavolt Technical Services (Sample) · invoiced by BARREL

Request quote

Solar module and inverter inspection, Eco 2 series

SampleServiceThird-party inspection (TPI)

Urjatek · URJ-AE8 series

Inspection effort
5 man-days to 100 man-days (see variants)
Equipment inspected
Towers and structures
Inspection stage
Raw material
Standards used
Per client specification
Inspector qualification
Level II NDT certified

Lead time Inspector assigned in 48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price for verified buyers

by Urjatek Projects (Sample) · invoiced by BARREL

Request quote

Civil and structural stage inspection, Pro 2 series

SampleServiceThird-party inspection (TPI)

Dwaraka · DWA-964 series

Inspection effort
20 man-days to 100 man-days (see variants)
Equipment inspected
PV modules and inverters
Inspection stage
Raw material
Standards used
Per client specification
Inspector qualification
Level II NDT certified

Lead time Inspector assigned in 48 hours · Warranty As per contract · MOQ 1 day

Price for verified buyers

by Dwaraka Projects (Sample) · invoiced by BARREL

Request quote

Kakatiyarajat · KAK-6E1 series

Inspection effort
1 man-day to 50 man-days (see variants)
Equipment inspected
Towers and structures
Inspection stage
Raw material
Standards used
Per client specification
Inspector qualification
Level II NDT certified

Lead time Report in 24-48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price for verified buyers

by Kakatiyarajat Consultants (Sample) · invoiced by BARREL

Request quote

Vidyutline · VID-095 series

Inspection effort
1 man-day to 50 man-days (see variants)
Equipment inspected
Cables and conductors
Inspection stage
In-process
Standards used
Per approved QAP
Inspector qualification
B.E. Electrical with 8 years experience

Lead time Inspector assigned in 48 hours · Warranty As per contract · MOQ 1 day

Price for verified buyers

by Vidyutline Technical Services (Sample) · invoiced by BARREL

Request quote

Civil and structural stage inspection, Edge series

SampleServiceThird-party inspection (TPI)

Kamrup · KAM-961 series

Inspection effort
10 man-days to 50 man-days (see variants)
Equipment inspected
Towers and structures
Inspection stage
In-process
Standards used
Per approved QAP
Inspector qualification
B.E. Electrical with 8 years experience

Lead time Inspector assigned in 48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price on quote

by Kamrup Projects (Sample) · invoiced by BARREL

Request quote

Urjatron · URJ-6E5 series

Inspection effort
1 man-day to 100 man-days (see variants)
Equipment inspected
Transformers and reactors
Inspection stage
In-process
Standards used
Per approved QAP
Inspector qualification
Level II NDT certified

Lead time Inspector assigned in 48 hours · Warranty As per contract · MOQ 1 day

Price on quote

by Urjatron Infra Services (Sample) · invoiced by BARREL

Request quote

Civil and structural stage inspection, Prime 3 series

SampleServiceThird-party inspection (TPI)

Lonavala · LON-968 series

Inspection effort
5 man-days to 100 man-days (see variants)
Equipment inspected
Towers and structures
Inspection stage
Raw material
Standards used
Per approved QAP
Inspector qualification
Level II NDT certified

Lead time Report in 24-48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price on quote

by Lonavala Logistics (Sample) · invoiced by BARREL

Request quote

Solar module and inverter inspection, Pro series

SampleServiceThird-party inspection (TPI)

Krishna · KRI-AE6 series

Inspection effort
1 man-day to 10 man-days (see variants)
Equipment inspected
Cables and conductors
Inspection stage
Final pre-dispatch
Standards used
Per client specification
Inspector qualification
B.E. Electrical with 8 years experience

Lead time Inspector assigned in 48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price for verified buyers

by Krishna Infra Services (Sample) · invoiced by BARREL

Request quote

Solar module and inverter inspection, Eco series

SampleServiceThird-party inspection (TPI)

Urjatek · URJ-AE1 series

Inspection effort
1 man-day to 100 man-days (see variants)
Equipment inspected
Cables and conductors
Inspection stage
Raw material
Standards used
Per approved QAP
Inspector qualification
Level II NDT certified

Lead time Inspector assigned in 48 hours · Warranty As per contract · MOQ 1 day

Price on quote

by Urjatek Projects (Sample) · invoiced by BARREL

Request quote

Solar module and inverter inspection, Volt 5 series

SampleServiceThird-party inspection (TPI)

Malwavolt · MAL-AE6 series

Inspection effort
20 man-days to 100 man-days (see variants)
Equipment inspected
Cables and conductors
Inspection stage
In-process
Standards used
Per client specification
Inspector qualification
Level II NDT certified

Lead time Report in 24-48 hours · Warranty As per contract · MOQ 1 day

Price for verified buyers

by Malwavolt Technical Services (Sample) · invoiced by BARREL

Request quote

Civil and structural stage inspection, Volt 2 series

SampleServiceThird-party inspection (TPI)

Dwaraka · DWA-963 series

Inspection effort
10 man-days to 50 man-days (see variants)
Equipment inspected
PV modules and inverters
Inspection stage
Raw material
Standards used
Per approved QAP
Inspector qualification
B.E. Electrical with 8 years experience

Lead time Inspector assigned in 48 hours · Warranty As per contract · MOQ 1 day

Price for verified buyers

by Dwaraka Projects (Sample) · invoiced by BARREL

Request quote

Vidyutline · VID-094 series

Inspection effort
5 man-days to 100 man-days (see variants)
Equipment inspected
PV modules and inverters
Inspection stage
Final pre-dispatch
Standards used
Per approved QAP
Inspector qualification
B.E. Electrical with 8 years experience

Lead time Report in 24-48 hours · Warranty As per contract · MOQ 1 day

Price for verified buyers

by Vidyutline Technical Services (Sample) · invoiced by BARREL

Request quote

Civil and structural stage inspection, Volt series

SampleServiceThird-party inspection (TPI)

Kamrup · KAM-966 series

Inspection effort
1 man-day to 100 man-days (see variants)
Equipment inspected
Towers and structures
Inspection stage
Final pre-dispatch
Standards used
Per approved QAP
Inspector qualification
Level II NDT certified

Lead time Inspector assigned in 48 hours · Warranty As per contract · MOQ 1 day

Price on quote

by Kamrup Projects (Sample) · invoiced by BARREL

Request quote

Kakatiyarajat · KAK-6E4 series

Inspection effort
5 man-days to 50 man-days (see variants)
Equipment inspected
Cables and conductors
Inspection stage
Raw material
Standards used
Per approved QAP
Inspector qualification
Level II NDT certified

Lead time Report in 24-48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price for verified buyers

by Kakatiyarajat Consultants (Sample) · invoiced by BARREL

Request quote

Cable drum inspection and sampling, Smart 8 series

SampleServiceThird-party inspection (TPI)

Kakatiya · KAK-215 series

Inspection effort
1 man-day to 50 man-days (see variants)
Equipment inspected
Cables and conductors
Inspection stage
Raw material
Standards used
Per approved QAP
Inspector qualification
Level II NDT certified

Lead time Inspector assigned in 48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price for verified buyers

by Kakatiya Logistics (Sample) · invoiced by BARREL

Request quote

Cable drum inspection and sampling, Edge series

SampleServiceThird-party inspection (TPI)

Maduraisurya · MAD-213 series

Inspection effort
5 man-days to 50 man-days (see variants)
Equipment inspected
Switchgear and relays
Inspection stage
Final pre-dispatch
Standards used
Per client specification
Inspector qualification
Level II NDT certified

Lead time Report in 24-48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price on quote

by Maduraisurya Technical Services (Sample) · invoiced by BARREL

Request quote

Civil and structural stage inspection, Xtra 4 series

SampleServiceThird-party inspection (TPI)

Lonavala · LON-963 series

Inspection effort
1 man-day to 50 man-days (see variants)
Equipment inspected
Towers and structures
Inspection stage
Final pre-dispatch
Standards used
Per approved QAP
Inspector qualification
Level II NDT certified

Lead time Inspector assigned in 48 hours · Warranty As per contract · MOQ 1 day

Price on quote

by Lonavala Logistics (Sample) · invoiced by BARREL

Request quote

Kaveridhruv · KAV-092 series

Inspection effort
5 man-days to 50 man-days (see variants)
Equipment inspected
PV modules and inverters
Inspection stage
Final pre-dispatch
Standards used
Per client specification
Inspector qualification
B.E. Electrical with 8 years experience

Lead time Inspector assigned in 48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price on quote

by Kaveridhruv Consultants (Sample) · invoiced by BARREL

Request quote

Mahanadiloha · MAH-6E5 series

Inspection effort
1 man-day to 10 man-days (see variants)
Equipment inspected
Switchgear and relays
Inspection stage
In-process
Standards used
Per approved QAP
Inspector qualification
B.E. Electrical with 8 years experience

Lead time Inspector assigned in 48 hours · Warranty Re-inspection at no cost for disputed lots · MOQ 1 day

Price for verified buyers

by Mahanadiloha Consultants (Sample) · invoiced by BARREL

Request quote

Solar module and inverter inspection, Elite 3 series

SampleServiceThird-party inspection (TPI)

Deccan · DEC-AE8 series

Inspection effort
1 man-day to 100 man-days (see variants)
Equipment inspected
Cables and conductors
Inspection stage
Final pre-dispatch
Standards used
Per approved QAP
Inspector qualification
B.E. Electrical with 8 years experience

Lead time Inspector assigned in 48 hours · Warranty As per contract · MOQ 1 day

Price on quote

by Deccan Engineering Services (Sample) · invoiced by BARREL

Request quote

Airavatsys · AIR-091 series

Inspection effort
5 man-days to 100 man-days (see variants)
Equipment inspected
Transformers and reactors
Inspection stage
In-process
Standards used
Per approved QAP
Inspector qualification
B.E. Electrical with 8 years experience

Lead time Report in 24-48 hours · Warranty As per contract · MOQ 1 day

Price for verified buyers

by Airavatsys Engineering Services (Sample) · invoiced by BARREL

Request quote

Mahanadiloha · MAH-6E1 series

Inspection effort
5 man-days to 100 man-days (see variants)
Equipment inspected
Switchgear and relays
Inspection stage
In-process
Standards used
Per client specification
Inspector qualification
Level II NDT certified

Lead time Report in 24-48 hours · Warranty As per contract · MOQ 1 day

Price for verified buyers

by Mahanadiloha Consultants (Sample) · invoiced by BARREL

Request quote

BARREL: Bharat Atom Renewable Resources Energy Limited